This study investigated the nanoleakage of root canal obturations using calcium silicate-based sealer according to different drying methods.
Fifty-two extracted mandibular premolars with a single root canal and straight root were selected for this study. After canal preparation with a nickel-titanium rotary file system, the specimens were randomly divided into 4 groups according to canal drying methods (1: complete drying, 2: blot drying/distilled water, 3: blot drying/NaOCl, 4: aspiration only). The root canals were obturated using a single-cone filling technique with a calcium silicate–based sealer. Nanoleakage was evaluated using a nanoflow device after 24 hours, 1 week, and 1 month. Data were collected twice per second at the nanoscale and measured in nanoliters per second. Data were statistically analyzed using the Kruskal-Wallis and Mann–Whitney
The mean flow rate measured after 24 hours showed the highest value among the time periods in all groups. However, the difference in the flow rate between 1 week and 1 month was not significant. The mean flow rate of the complete drying group was the highest at all time points. After 1 month, the mean flow rate in the blot drying group and the aspiration group was not significantly different.
Within the limitations of this study, the canal drying method had a significant effect on leakage and sealing ability in root canal obturations using a calcium silicate-based sealer. Thus, a proper drying procedure is critical in endodontic treatment.
No studies have yet assessed vibration characteristics according to endodontic file length. Accordingly, the objective of the present study was to examine the vibration characteristics according to nickel-titanium file length and to compare these characteristics between different file systems.
A total of 45 root canal models were divided into 3 experimental groups (
In the PTG file system, significantly lower vibration acceleration was observed when using a 21-mm file than when using a 31-mm file. In the WOG file system, significantly stronger vibration acceleration was observed when using a 31-mm file than when using 21- or 25-mm files. Regardless of the file length, the WOG group exhibited significantly stronger vibration acceleration than the other 2 experimental groups.
In clinical practice, choosing a file with the shortest length possible could help reduce vibrations. Additionally, consideration should be given to vibrations that could be generated when using WOG files with reciprocating motion.
This study aimed to investigate the incidence and location of the second mesiobuccal root (MB2) canal in maxillary molars with the aid of various measuring points and lines using cone-beam computed tomography (CT).
A total of 205 images of patients who underwent cone-beam CT examinations between 2011 and 2015 as part of their dental diagnosis and treatment were included. There were 76 images of the maxillary first molar and 135 images of the maxillary second molar. Canal orifices were detected at −1 mm from the top of the pulpal floor on cone-beam CT images. Image assessment was performed by 2 observers in reformatted image planes using software. Assessments included measurement of the distance between the MB1 and MB2 canals, and the angles between the lines connecting the MB1-MB2 and distobuccal (DB)-palatal (P) canals. The data were analyzed using the student's
The prevalence of the MB2 canal was 86.8% in the first molar and 28.9% in the second molar. The angle between the lines connecting the MB1-MB2 and DB-P canals was 2.3° ± 5.7° in the first molar and −3.95° ± 7.73° in the second molar. The distance between the MB1 and MB2 canals was 2.1 ± 0.44 mm in the first molar and 1.98 ± 0.42 mm in the second molar.
The angles between the lines connecting the MB1-MB2 and DB-P canals was almost parallel. These findings may aid in the prediction of the location of the MB2 canal orifice.
The replacement of missing teeth, especially in the anterior region, is an essential part of dental practice. Fiber-reinforced composite resin bridges are a conservative alternative to conventional fixed dental prostheses or implants. It is a minimally invasive, reversible technique that can be completed in a single visit. The two cases presented herein exemplify the treatment of root-fractured anterior teeth with a natural pontic immediately after extraction.
The purpose of this study was to measure the temperature of the plugger tip of 3 cordless heat carriers set at 200°C.
Pluggers of the same taper (0.06, 0.08, 0.10) and similar tip sizes (sizes of 50 and 55) from 3 cordless heat carriers, namely SuperEndo-α2 (B & L Biotech), Friendo (DXM), and Dia-Pen (Diadent), were used and an electric heat carrier, System B (SybronEndo), was used as the control. The plugger tips were covered with customized copper sleeves, heated for 10 seconds, and the temperature was recorded with a computerized measurement system attached to a K-type thermometer at room temperature (
The peak temperature of the plugger tips was significantly affected by the plugger taper and by the heat carrier brand (
When using cordless heat carriers, clinicians should pay attention to the temperature setting and to the activation time needed to reach the intended temperature of the pluggers.
Periapical lesions, including periapical cyst (PC), periapical granuloma (PG), and periapical abscess (PA), are frequently affected by chemical/physical damage during root canal treatment or severe bacterial infection, and thus, the differential diagnosis of periapical lesions may be difficult due to the presence of severe inflammatory reaction. The aim of this study was to make differential diagnosis among PC, PG, and PA under polarizing microscope.
The collagen birefringence patterns of 319 cases of PC (
Collagen birefringence was condensed with a thick, linear band-like pattern in PC, but was short and irregularly scattered in PG, and scarce or absent in PA. PF showed intense collagen birefringence with a short, palisading pattern but no continuous band-like pattern. The linear band-like birefringence in PC was ascribed to pre-existing expansile tensile stress of the cyst wall.
In this study all PCs (
The aim of this study was to compare the dimensional standard of several nickel-titanium (Ni-Ti) rotary files and verify the size conformity.
ProFile (Dentsply Maillefer), RaCe (FKG Dentaire), and TF file (SybronEndo) #25 with a 0.04 and 0.06 taper were investigated, with 10 in each group for a total of 60 files. Digital images of Ni-Ti files were captured under light microscope (SZX16, Olympus) at 32×. Taper and diameter at D1 to D16 of each files were calculated digitally with AnalySIS TS Materials (OLYMPUS Soft Imaging Solutions). Differences in taper, the diameter of each level (D1 to D16) at 1 mm interval from (ANSI/ADA) specification No. 101 were statistically analyzed using one-way ANOVA and Scheffe's
TF was the only group not conform to the nominal taper in both tapers (
Actual size of Ni-Ti file, especially TF, was different from the manufacturer's statements.
This is a case report of chronic maxillary sinusitis caused by root canal overfilling of Calcipex II (Techno-Dent). A 60 year-old male complained of dull pain in the right maxillary molar area after complicated endodontic treatment using Calcipex II paste and was finally diagnosed with a chronic maxillary sinusitis through a clinical and radiological observation. In the biopsy examination, the periapical granuloma contained a lot of dark and translucent Calcipex II granules which were not stained with hematoxylin and eosin. They were usually engulfed by macrophages but rarely resorbed, resulting in scattering and migrating into antral mucosa. Most of the Calcipex II granules were also accumulated in the cytoplasms of secretory columnar epithelial cells, and small amount of Calcipex II granules were gradually secreted into sinus lumen by exocytosis. However, chronic granulomatous inflammation occurred without the additional recruitment of polymorphonuclear leukocytes (PMNs) and lymphocytes, and many macrophages which engulfed the Calcipex II granules were finally destroyed in the processes of cellular apoptosis. It is presumed that Calcipex II granules are likely to have a causative role to induce the granulomatous foreign body inflammation in the periapical region, and subsequently to exacerbate the chronic maxillary sinusitis in this study.
To evaluate the accuracy of the Root ZX in teeth with simulated root perforation in the presence of gel or liquid type endodontic irrigants, such as saline, 5.25% sodium hypochlorite (NaOCl), 2% chlorhexidine liquid, 2% chlorhexidine gel, and RC-Prep, and also to determine the electrical conductivities of these endodontic irrigants.
A root perforation was simulated on twenty freshly extracted teeth by means of a small perforation made on the proximal surface of the root at 4 mm from the anatomic apex. Root ZX was used to locate root perforation and measure the electronic working lengths. The results obtained were compared with the actual working length (AWL) and the actual location of perforations (AP), allowing tolerances of 0.5 or 1.0 mm. Measurements within these limits were considered as acceptable. Chi-square test or the Fisher's exact test was used to evaluate significance. Electrical conductivities of each irrigant were also measured with an electrical conductivity tester.
The accuracies of the Root ZX in perforated teeth were significantly different between liquid types (saline, NaOCl) and gel types (chlorhexidine gel, RC-Prep). The accuracies of electronic working lengths in perforated teeth were higher in gel types than in liquid types. The accuracy in locating root perforation was higher in liquid types than gel types. 5.25% NaOCl had the highest electrical conductivity, whereas 2% chlorhexidine gel and RC-Prep gel had the lowest electrical conductivities among the five irrigants.
Different canal irrigants with different electrical conductivities may affect the accuracy of the Root ZX in perforated teeth.
The purpose of this study was to evaluate the relation between intentionally induced internal stress and cyclic fatigue failure of .06 taper ProFile.
Length 25 mm, .06 taper ProFile (Dentsply Maillefer), and size 20, 25, 30, 35 and 40 were used in this study. To give the internal stress, the rotary NiTi files were put into the .02 taper, Endo-Training-Bloc (Dentsply Maillefer) until auto-stop by torque controlled motor. Rotary NiTi files were grouped by the number of induced internal stress and randomly distributed among one control group and three experimental groups (
In .06 taper ProFile size 20, 25, 30, 35 and 40, there were statistically significant difference on time for separation between control group and the other groups (
In the limitation of this study, cyclic fatigue failure of .06 taper ProFile is influenced by internal stress accumulated in the files.
This study aimed to evaluate the relationship between the cyclic fatigue of a K3 file and internal stress intentionally induced until the activation of the auto-stop function of the torque-controlled motor.
K3 (Sybron Endo) .04 and .06 taper, size 25, 30, 35, 40 and 45 were used in this study. To give the internal stress, the K3 files were put into the .02 taper Endo-Training-Bloc (Dentsply Maillefer) until the activation of the auto-stop function of the torque-controlled motor. The rotation speed was 300 rpm and torque value was 1.0 N·cm. K3 were grouped by the number of induced internal stress and randomly distributed to 4 experimental groups (
Except .04 taper size 30 in Stress 1 group, there were statistically significant differences in time for file separation between control and all experimental groups. K3 with .04 taper showed higher cyclic fatigue resistance than those of .06 taper.
In the limitation of this study, the cyclic fatigue of the K3 file was influenced by the accumulated internal stress from use until the auto-stop function was activated by the torque-controlled motor. Therefore, clinicians should avoid the reuse of the K3 file that has undergone auto-stops.
Palatogingival groove is a developmental anomaly that starts near the cingulum of the tooth and runs down the cementoenamel junction in apical direction, terminating at various depths along the roots. While frequently associated with periodontal pockets and bone loss, pulpal necrosis of these teeth may precipitate a combined endodontic-periodontal lesion. This case presents a case of a lateral incisor anatomically complicated with palatogingival groove.
Two patients with lesion associated with the palatogingival groove were chosen for this report. Palatogingival grooves were treated with different restoration materials with endodontic treatment.
Maxillary lateral incisor with a palatogingival groove may occur the periodontal disease with pulpal involvement. Elimination of groove may facilitate the periodontal re-attachment and prevent the recurrence.
The purpose of this study was to evaluate curing degree of three dual-cure resin cements with the elapsed time in self-cure and dual-cure mode by means of the repeated measure of micro-hardness.
Two dual-cure self-adhesive resin cements studied were Maxcem Elite (Kerr), Rely-X Unicem (3M ESPE) and one conventional dual-cure resin cement was Rely-X ARC resin cement (3M ESPE). Twenty specimens for each cements were made in Teflon mould and divided equally by self-cure and dual-cure mode and left in dark, 36℃, 100% relative humidity conditional-micro-hardness was measured at 10 min, 30 min, 1 hr, 3 hr, 6 hr, 12 hr and 24 hr after baseline. The results of micro-hardness value were statistically analyzed using independent samples
The micro-hardness values were increased with time in every test groups. Dual-cure mode obtained higher micro-hardness value than self-cure mode except after one hour of Maxcem. Self-cured Rely-X Unicem showed lowest value and dual-cured Rely-X Unicem showed highest value in every measuring time.
Sufficient light curing to dual-cure resin cements should provided for achieve maximum curing.
The purpose of this study was to evaluate the effect of surface treatment of FRC-Post on bonding strength to resin cements.
Pre-surface treated LuxaPost (DMG), Rely-X Fiber Post (3M ESPE) and self adhesive resin cement Rely-X Unicem (3M ESPE), conventional resin cement Rely-X ARC (3M ESPE), and Rely-X Ceramic Primer (3M ESPE) were used. After completing the surface treatments of the posts, posts and resin cement were placed in clear molds and photo-activation was performed. The specimens were sectioned perpendicular to the FRC-Post into 2 mm-thick segments, and push-out strength were measured. The results of bond strength value were statistically analyzed using independent samples
Silanization of posts affect to the bond strength in LuxaPost, and did not affect in Rely-X Fiber Post. Rely-X ARC showed higher value than Rely-X Unicem.
Silanization is needed to enhance the bond strength between LuxaPost and resin cements.
The purpose of this study was to evaluate a rotational stability of endodontic electronic motors by comparing the changes of rotational speed, depending on the number of usages and with/without static load. Twelve new endodontic electronic motors were used in this study. Non contact type digital tachometer was used for measuring the rotational speed of handpiece. True RMS Multimeter was used for measuring the voltages and the electric currents. All measurements were recorded every 10 seconds during 10 minutes and repeated 9 times. Five repetition was done per each electronic motor. To statistical analysis, student t-test, repeated measures and Scheffe's post-hoc tests were performed. In the same motor group, there was no significant difference in all measurements. In all groups, there was no significant difference in the amount of rotational speed changes depending on the number of usages and with/without static load. In the limitation of this study, the results showed that all kinds of endodontic electronic motors in this study had an established rotational stability. Therefore they could be safely used in root canal treatment with a reliable maintenance of rotational speed, regardless of the number of usages and with/without load.
The purpose of this study was to compare radiopacity and radiographic discriminability of various FRC-Posts.
Six FRC-Posts were investigated ; 1) FRC Postec Plus (Ivoclar Vivadent AG, Schaan, Liechtenstein), 2) Snowlight (Carbotech, Lewis center, OH, USA), 3) Dentin Post (Komet Brasseler, Lamgo, Germany), 4) Rely-X Fiber Post (3M ESPE, St.paul, MN, USA), 5) D.T.-Light Post (BISCO, Schaumburg, IL,USA), 6) Luxapost (DMG, Hamburg, Germany)
The radiographs of each post with a reference 1 mm / 2 mm aluminum step-wedge was taken using digital sensor. The optical density were calculated by gray value of 10 × 10 pixel and compared in mm Al equivalent at five points.
Six maxillary incisors of similar radiopacity were used. Radiographs of posts in Mx. incisors of lingual side of dry mandible were taken.
We showed radiographs and asked the questionnaire to 3 radiologists, 3 endodontists, 3 general practitioners. The questionnaire was comprised of choices of the highest, lowest radiopaque individual post and the choices of best discriminable post at apical, coronal area.
The following results were obtained.
Each post system showed various radiopacity. There was change of discriminability between each post and simulated specimens regardless of examiner.
Although each post showed various radiopacity, the difference of radiopacity did not affect on discriminability.
The purpose of this study was to compare the different canal irrigation methods to prevent the formation of precipitate between sodium hypochlorite (NaOCl) and chlorhexidine (CHX).
Extracted 50 human single-rooted teeth were used. The root canals were instrumented using NiTi rotary file (Profile .04/#40) with 2.5% NaOCl and 17% EDTA as irrigants. Teeth were randomly divided into four experimental groups and one control group as follows; Control group: 2.5% NaOCl only, Group 1: 2.5% NaOCl + 2% CHX, Group 2: 2.5% NaOCl + paper points + 2% CHX, Group 3: 2.5% NaOCl + preparation with one large sized-file + 2% CHX, Group 4: 2.5% NaOCl +95% alcohol+ 2% CHX.
The teeth were split in bucco-lingual aspect and the specimens were observed using Field Emission Scanning Electron Microscope. The percentages of remaining debris and patent dentinal tubules were determined. Statistical analysis was performed with one-way analysis of variance (ANOVA). Energy Dispersive x-ray Spectroscopy was used for analyzing the occluded materials in dentinal tubule for elementary analysis.
There were no significant differences in percentage of remaining debris and patent tubules between all experimental groups at all levels (p > .05).
In elementary analysis, the most occluded materials in dentinal tubule were dentin debris. NaOCl/CHX precipitate was detected in one tooth specimen of Group 1.
In conclusion, there were no significant precipitate on root canal, but suspected material was detected on Group 1. The irrigation system used in this study could be prevent the precipitate formation.
Mouthguards were used to protect boxers from lip lacerations and other soft tissue injuries in the late 19th century. Now they are used various parts of dental treatment, which are sports protective aid, bleaching tray, orthodontic retainer, implant insertion guide tray, splint and so on.
Repeated dislodgement of Class V restoration due to habitual clenching stress should be restored with stress control. Mouthguard can be used as stress relief device.
This case describes methods that can relieve occlusal force to teeth by using mouthguard.
Satisfactory results can be obtained by using mouthguard for retention of repeated dislodgement Class V restorations.
If patients suffered from repeated restorations of Class V due to clenching, mouthguard can be used additional device to relieve the occlusal stress in conservative dentistry.
There are a number of situations where the oral mucosa can be sucked or pressed to produce relatively banal but clinical distinctive changes. The labial and buccal mucosa and tongue may develop protuberances in areas where a tooth is missing or extra space is present. The mucosa is pressed and sucked into these spaces, thus leading to the development of a fibrous hyperplasia.
This case report describes the management of fibrous hyperplasia in oral mucosa.
Fibrous hyperplasia can be formed by habitual pressure or suction in oral mucosa. Treatment of fibrous hyperplasia consists of simple excision and, if feasible, elimination of the cause. And habit control is a important factor for preventing recurrence.
The aim of this study was to evaluate the influence of light energy on the tooth whitening effect of bleaching agent in vitro. Extracted human mandibular molars were sectioned to 2 fragments(mesial, distal) and lingual portions of crown were used in this study. All specimens were stained using a red wine for 24 hours and immersed in artificial saliva. Specimens divided into four groups, group 1 and 2 light-activated by LumaCool (LED, LumaLite, Inc., Spring Valley, USA), group 3 and 4 light-activated by FlipoWhite2 (Plasma acr lamp, Lokki, Australia). Group 1 and 3 bleached with LumaWhite(LumaLite, Inc., Spring Valley, USA), group 2 and 4 bleached with Polaoffice(SDI, Victoria, Australia). Bleaching treatment performed during 10 minutes every 24 hours and repeated 6 times. During bleaching treatment , distal fragments was light-activated(L) but mesial fragments was not(NL). Shade assessment employed before and after bleaching treatment using spectrophotometer. The results of the change in shade was compared and analysed between NL and L by using paired-sample T test with 95% level of confidence.
There were no significant differences between NL and L with a few exceptions. In group 2, a* value more change in L, in group 3, b* value more change in L, in group 4, a* value less change in L. After bleaching, L* value and ΔE increased in all groups and the value of a* and b* decreased in all groups.
Within the limitation of this test conditions, the results of this study indicate that the light energy has no obvious improving impact on the tooth whitening effect of a bleaching agent.
When we use the total-etch dentin adhesive system for composite resin restorations, gel or liquid acid etchant such as 37% phosphoric acid is commonly used. Thirty seven percentage phosphoric acid is very powerful erosive agent, and can cause severe harmful effects when it contacts with an oral mucosa and facial skin.
This case describes iatrogenic chemical burn on facial skin caused by phosphoric acid which was happened during composite resin restorative procedure.
Chemical burn by acid etchant can be evoked by careless handling of remnant and syringe. In order to prevent these iatrogenic injuries, we should check the complete removal of the etching agent both in intra and extra-oral environments after etching and rinsing procedure and it is necessary to use of the rubber dam or isolation instruments.
If accidental burn were occurred, immediate wash with copious water. And bring the patient to the dermatologist as soon as possible.
The purposes of this study were to compare the efficacy of irrigation systems by removing a calcium hydroxide (Ca(OH)2) paste from the apical third of the root canal and the effect of the patency file. Sixty single rooted human teeth were used in this study. The canals were instrumented by a crown-down manner with .04 taper ProFile to ISO #35. Ca(OH)2 and distilled water were mixed and placed inside the root canals. The teeth were divided into 6 groups according to the root canal irrigation system and the use of patency file as follows: group 1 - conventional method; group 2 - EndoActivator®; group 3 - EndoVac®; group 4 - conventional method, patency; group 4 - EndoActivator®, patency; group 6 - EndoVac®, patency. All teeth were irrigated with sodium hypochlorite. After the root canal irrigation, the teeth were split in bucco-lingual aspect. Percentage of the root canal surface coverage with residual Ca(OH)2 until 3 mm from working length was analyzed using Image Pro Plus ver. 4.0. Statistical analysis was performed using the One-way ANOVA, t-test and Scheffe's post-hoc test. Conventional groups had significantly more Ca(OH)2 debris than EndoActivator®, EndoVac® groups. There was no significant difference between EndoActivator® and EndoVac® groups. Groups with patency file showed more effective in removing Ca(OH)2 paste than no patency groups, but, it was no significant difference. This study showed that EndoActivator® and EndoVac® systems were more effective in removing Ca(OH)2 paste from the apical third of the root canal than conventional method.
The purpose of this study was to compare the tensile bond strength of several self-adhesive resin cements bonded to dentin surfaces with different wet conditions.
Three self-adhesive resin cements; Rely-X Unicem (3M ESPE, St. Paul, MN, USA), Embrace Wetbond (Pulpdent, Oakland, MA, USA), Maxcem (Kerr, Orange, CA, USA) were used. Extracted sixty human molars were used. Each self-adhesive resin cement was adhered to the dentin specimens (two rectangular sticks from each molar) in different wet conditions.
Tensile bond strength were measured using universal testing machine (EZ Test, Shimadzu corporation, Kyoto, Japan) at a crosshead speed of 1.0mm/min. After the testing, bonding failures of specimens were observed by Operative microscope (OPMI pro, Carl Zeiss, Oberkochen, Germany). T-test was used to evaluate the effect of dentin surface wetness. One-way ANOVA test was used to evaluate the tensile bond strength of self-adhesive resin cements in the same condition. Scheffe's test was used for statistical analyzing at the 95% level of confidence.
The result showed that wetness of dentin surface didn't affect tensile bond strength of self-adhesive resin cements and Maxcem showed the lowest tensile bond strength.
The purpose of this study was to compare the apical microleakage in root canal filled with Resilon by methacrylate-based root canal sealer or 2 different self-adhesive resin cements. Seventy single-rooted extracted human teeth were sectioned at the CEJ perpendicular to the long axis of the roots with diamond disk. Canal preparation was performed with crown-down technique using Profile NiTi rotary instruments and GG drill. Each canal was prepared to ISO size 40, .04 taper and 1 mm short from the apex. The prepared roots were randomly divided into 4 experimental groups of 15 roots each and 5 roots each for positive and negative control group. The root canals were filled by lateral condensation as follows. Group 1: Guttapercha with AH-26, Group 2: Resilon with RealSeal primer & sealer, Group 3: Resilon with Rely-X Unicem, Group 4: Resilon with BisCem. After stored in 37℃, 100% humidity chamber for 7 days, the roots were coated with 2 layers of nail varnish except apical 3 mm. The roots were then immersed in 1% methylene blue dye for 7 days. Apical microleakage was measured by a maximum length of linear dye penetration after roots were separated longitudinally. One way ANOVA and Scheffe's post-hoc test were performed for statistical analysis. Group 1 showed the least apical leakage and there was no statistical significance between Group 2, 3, 4. According to the results, the self adhesive resin cement is possible to use as sealer instead of primer & sealant when root canal filled by Resilon.
The purpose of this study was to compare the apical microleakage in root canal filled with Resilon by several self-etching primers and methacrylate-based root canal sealer. Seventy single-rooted human teeth were used in this study. The canals were instrumented by a crown-down manner with Gate-Glidden drills and .04 Taper Profile to ISO #40. The teeth were randomly divided into four experimental groups of 15 teeth each according to root canal filling material and self-etching primers and two control groups (positive and negative) of 5 teeth each as follows: group 1 - gutta percha and AH26® sealer; group 2 - Resilon, RealSeal™ primer and RealSeal™ sealer; group 3 - Resilon, Clearfil SE Bond® primer and RealSeal™ sealer group 4 - Resilon, AdheSe® primer and RealSeal™ sealer. Apical leakage was measured by a maximum length of linear dye penetration of roots sectioned longitudinally by diamond disk. Statistical analysis was performed using the One-way ANOVA followed by Scheffe's test. There were no statistical differences in the mean apical dye penetration among the groups 2, 3 and 4 of self-etching primers. And group 1, 2 and 3 had also no statistical difference in apical dye penetration. But, there was statistical difference between group 1 and 4 (p < 0.05). The group 1 showed the least dye penetration. According to the results of this study, Resilon with self-etching primer was not sealed root canal better than gutta precha with AH26® at sealing root canals. And there was no significant difference in apical leakage among the three self-etching primers.
The purpose of this study was to assess the antibacterial effect of sodium dichloroisocyanurate (NaDCC), sodium hypochlorite (NaOCl), and chlorhexidine (CHX) on
Extracted human single teeth were prepared by serial instrumentation technique. The samples were autoclaved and contaminated for 3 days with
NaOCl and NaDCC solution shows similar antimicrobial effect for
The results are in agreement with other investigators, who have shown the bactericidal property and possibility of NaDCC as a root canal irrigation solution. Thus it seems that NaDCC solutions can be clinically applied into the root canal within 1 week after dilution.
The objective of this
Microhardness (Microhardness tester, Zwick) of each specimen was measured at the baseline of pre-treatment, immediate after bleaching treatment, 14 days after bleaching treatment and Knoop Hardness Number was determined. Microhardness changes of experimental groups were compared.
The results show that tooth whitening strip and gel used in this study does not effect the micro-hardness of enamel during bleaching procedure.
During root canal preparation procedures, the potential for instrument separation is always present. Files, a lentulo, a Gates-Glidden (GG) bur or any manufactured obstruction can be left behind in the canal. Nickel-titanium (NiTi) rotary files are in common usage in these days. Despite their undeniable advantages, there is a potential risk of separation within the canals. It is very rapid, unpredictable, and creates a great deal of stress for the practitioner.
When an endodontic instrument separates, the best option is to remove it. Ultrasonic instruments and microscopes have improved the success rate for removing separated instruments. But it is difficult and not always possible. Therefore prevention is the key.
In this case report, several management methods of separated file in the canal are presented.
Intracanal separation of the rotary files is a serious concern in modern endodontic practice. The objective of this study was to compare the life span and fracture patterns of three NiTi rotary files in molar teeth.
Mesiobuccal roots of upper molar (n = 150) and mesial roots of lower molar (n = 150) were divided into three groups and each group was prepared with Profile, ProTaper, and K3 respectively. Every file was used until separation and/or deterioration of the cutting blade was happened, and then the number of canals to separation and/or unwinding were recorded. Radiographs and Scanning electon microscope (SEM) photographs were taken to evaluate the patterns of separation.
The results were as follows :
1. There were no significant differences in numbers of canals to separation and/or unwinding among the groups.
2. Comparing between flaring files, K3 showed significant lower numbers of canals to separation and/or unwinding (p < 0.05), and there was no significant difference between shaping files
3. Separations of instruments were occurred at the midpoint of curvatures within the canals.
4. In SEM observations, ductile fractures were seen in most of cases, characterized by shallow dimples.
Additional researches is needed to provide a new guideline that informs the appropriate number of times to use NiTi files.