Warning: mkdir(): Permission denied in /home/virtual/lib/view_data.php on line 81

Warning: fopen(upload/ip_log/ip_log_2024-12.txt): failed to open stream: No such file or directory in /home/virtual/lib/view_data.php on line 83

Warning: fwrite() expects parameter 1 to be resource, boolean given in /home/virtual/lib/view_data.php on line 84
Rotational stability of endodontic motors
Skip Navigation
Skip to contents

Restor Dent Endod : Restorative Dentistry & Endodontics

OPEN ACCESS

Articles

Page Path
HOME > Restor Dent Endod > Volume 39(3); 2014 > Article
Readers' Forum Rotational stability of endodontic motors
Se-Hee Park
Restorative Dentistry & Endodontics 2014;39(3):240-240.
DOI: https://doi.org/10.5395/rde.2014.39.3.240
Published online: May 20, 2014

Gangneung-Wonju National University, Korea.

©Copyights 2014. The Korean Academy of Conservative Dentistry.

This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

  • 18 Views
  • 0 Download
prev next
I always worry about rotary file separation during root canal preparation since the rotational speed of the electronic endodontic motor seems unstable. Does an electronic endodontic motor have reliable rotational stability regardless of the power supply via AC adapter or battery?
Recently, nickel-titanium (NiTi) engine-driven rotary instruments have become a mainstay for not only endodontists but also general practitioners. Among the various motors, wireless electronic motors are becoming popular to dentists for various reasons: they are relatively inexpensive, have lighter weight than traditional motors, and dentists can easily use them due to their wireless feature. Wireless electronic motors use rechargeable batteries as power source. The output of rechargeable batteries can change depending on usage, residual capacity of batteries, temperature and the duration of use. If there is a change in the output of batteries, rotations per minutes (RPM) of wireless electronic motors may tend to change, resulting in different motion and unexpected RPM change.1 It acts like that of air pressure in an air-driven motor where a drop in air pressure can lead to a decrease of rotational speed. When the rotational speed is decreased, the instrument may become less active, and the operator may tend to force the instrument into the canal, leading to deformation and separation.2
During wireless electronic motor use, the actual RPM values were significantly lower than the RPM set on the motor but there was a little change in the rotational speed.3 These results were in agreement with another study that showed similar significant variations during the use of Tri Auto ZX (J. Morita MFG. Co., Kyoto, Japan).4 A change of rotational speed from 240 to 280 rpm was observed during usual preparation procedure when using the engine driven with rechargeable battery, and this change is negligible.4
There was a study on the RPM changes according to power source. It showed that there was no difference in changes of rotational speed between the power supplied by the AC adapter and rechargeable battery. An endodontic wireless electronic motor with a rechargeable battery may be safely used continuously up to 180 minutes with a reliable RPM maintenance.3 In addition, according to a study on the rotational stability in endodontic electronic motors, all kinds of endodontic electronic motors had an established rotational stability with/without load.1
Readers' forum is edited by Professor Kyung-Mo Cho (Gangneung-Wonju National University).
  • 1. Park SH, Seo HW, Hong CU. An evaluation of rotational stability in endodontic electronic motors. J Korean Acad Conserv Dent 2010;35:246-256.Article
  • 2. Yared GM, Bou Dagher FE, Kulkarni GK. Influence of torque control motors and the operator's proficiency on ProTaper failures. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2003;96:229-233. ArticlePubMed
  • 3. Park SH, Jeong DB, Cho KM, Kim JW. The evaluation of RPM change in X-Smart according to power source; endodontic wireless electronic motor. J Dent Rehabil Appl Sci 2011;27:91-97.
  • 4. Kobayashi C, Yoshioka T, Suda H. A new engine-driven canal preparation system with electronic canal measuring capability. J Endod 1997;23:751-754. PubMed

Tables & Figures

REFERENCES

    Citations

    Citations to this article as recorded by  

      • ePub LinkePub Link
      • Cite
        CITE
        export Copy Download
        Close
        Download Citation
        Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

        Format:
        • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
        • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
        Include:
        • Citation for the content below
        Rotational stability of endodontic motors
        Restor Dent Endod. 2014;39(3):240-240.   Published online May 20, 2014
        Close
      • XML DownloadXML Download
      Rotational stability of endodontic motors
      Rotational stability of endodontic motors

      Restor Dent Endod : Restorative Dentistry & Endodontics
      Close layer
      TOP