The Effect of canal obturation according to the depth of the System B Plugger tip in the Type IV canal
-
Hee-Won Choi, Soo-Mee Kim, Ho-Keel Hwang
-
J Korean Acad Conserv Dent 2008;33(6):518-525. Published online November 30, 2008
-
DOI: https://doi.org/10.5395/JKACD.2008.33.6.518
-
-
Abstract
PDFPubReaderePub
The purpose of this study was to evaluate the effect of the apical sealing according to the depth of the System B Plugger tip when root canal was filled with gutta-percha and sealer by Continuous Wave of Condensation technique in the Type IV canal.
50 simulated resin blocks with J-shaped curvature canals were instrumented by ProTaper (Dentsply Maillefer, Ballagiues, Switzerland) Ni-Ti files using the crown-down technique. Type IV canals were made using a broken ProTaper F3 Ni-Ti file for making a ledge at 3mm short from the working length. And ProTaper F1 Ni-Ti file was used for perforating resin block.
The prepared Type IV canals were randomly divided into three experimental groups of 15 each according to the depth of System B Plugger tip.
All of experimental groups were obturated with Continuous Wave of Condensation technique. The length of gutta-percha and sealer in lingual of the Type IV canals was measured with a measuring digital calliper under magnifying glass (× 2.3).
The results are as follows :
In control group, there was no gutta-percha and sealer in lingual canal.
3 mm group showed relatively more gutta-percha than 5mm or 7 mm group (p<0.05).
7 mm group did not showed gutta-percha and relatively more void were observed than 3mm or 5 mm group. (p<0.05)
In conclusion, within the limits of the results of this experiment, the 3 mm depth of System B Plugger tip was acceptable for obturating the Type IV canal.
-
Effect of the application time of self-etching primers on the bonding of enamel
-
Cheol-Hee Jin, Young-Gon Cho, Soo-Mee Kim, Myeong-Seon Lee
-
J Korean Acad Conserv Dent 2008;33(3):224-234. Published online May 31, 2008
-
DOI: https://doi.org/10.5395/JKACD.2008.33.3.224
-
-
Abstract
PDFPubReaderePub
The purpose of this study was to compare the normal and two times of application time of six self-etching primers applied to enamel using microshear bond strength (uSBS) test and the finding of scanning electronic microscope (SEM).
Crown of sixty human molars were bisected mesiodistally and buccal and lingual enamel of crowns were partially exposed and polished with 600 grit SiC papers. They were divided into one of two equal groups subdivided into one of six equal groups (n = 10) by self-etching primer adhesives.
After the same manufacture's adhesive resin and composites were bonded on the enamel surface of each group, the bonded specimens were subjected to uSBS testing and also observed under SEM.
In conclusion, generally two times of primer application time increased the enamel uSBS, especially with the statistical increase of bond strength in adhesives involving high-pH primers.
-
EVALUATION ON THE ABRASION RESISTANCE OF A SURFACE SEALANT
-
Soo-Mee Kim, Sae-Hee Han, Young-Gon Cho
-
J Korean Acad Conserv Dent 2007;32(3):180-190. Published online January 14, 2007
-
DOI: https://doi.org/10.5395/JKACD.2007.32.3.180
-
-
Abstract
PDFPubReaderePub
- Abstract
The purpose of this study was to evaluate the abrasion resistance of surface penetrating sealant which was applied on a composite resin restoration and to provide proper time to reapply sealant on composite resin surface.
Two hundred rectangular specimens, sized 8 × 3 × 2 mm, were made of Micronew (Bisco, Inc., Schaumburg, IL, U.S.A) and divided into two groups; F group (n = 10) was finished with coarse and medium grit of Sof-Lex discs and BisCoverwas applied B group (n = 190) after finishing with discs. B group was again subdivided into nineteen subgroups. From B-1 group to B-18 group were subjected to toothbrush abrasion test using a distilled water-dentifrice slurry and toothbrush heads. B-IM group was not subjected to toothbrush abrasion test.
Average surface roughness (Ra) of each group was calculated using a surface roughness tester (Surfcorder MSE-1700: Kosaka Laboratory Ltd., Tokyo, Japan). A representative specimen of each group was examined by FE-SEM (S-4700: Hitachi High Technologies Co., Tokyo, Japan). The data were analysed using cluster analysis, paired t-test, and repeated measure ANOVA. The results of this study were as follows;
Ra of F group was 0.898 ± 0.145 μm and B-IM group was 0.289 ± 0.142 μm. Ra became higher from B-1 group (0.299 ± 0.48 μm) to B-18 group (0.642 ± 0.313 μm).
Final cluster center of Ra was 0.361 μm in cluster 1 (B-IM ∼ B-7), 0.511 μm in cluster 2 (B-8 ∼ B-14) and 0.624 μm in cluster 3 (B-15 ∼ B-18). There were significant difference among Ra of three clusters.
Ra of B-IM group was decreased 210.72% than Ra of F group. Ra of B-8 group and B-15 group was increased 35.49% and 51.35% respectively than Ra of B-IM group.
On FE-SEM, B-IM group showed the smoothest resin surface. B-8 group and B-15 group showed vertically shallow scratches, and wide and irregular vertical scratches on composite resin surface respectively.
Within a limitation of this study, finished resin surface will be again smooth and glazy if BisCover would be reapplied within 8 to 14 months after applying to resin surface.
-
Color changes in composite resins exposed to xenon lamp
-
Young-Gon Cho, Jeong-Il Seo, Soo-Mee Kim, Jin-Ho Jeong, Young-Gon Lee
-
J Korean Acad Conserv Dent 2003;28(3):195-202. Published online May 31, 2003
-
DOI: https://doi.org/10.5395/JKACD.2003.28.3.195
-
-
Abstract
PDFPubReaderePub
The purpose of this study was to evaluate the color changes of the composite resin resulting from xenon lamp exposure in different environments. Composite resin (Z 250 ; shade A1, A2, A3, A3.5, and A4) were applied in a cylindrical metal mold. Seventy five specimens according to environments of exposure were made as follows;
Group I: aluminum foiling of the specimens in the air at 37℃ for 1 day and 7 days.
Group II: exposure of xenon lamp to the specimens in the air at 37℃ for 1 day and 7 days.
Group III: exposure of xenon lamp to the specimens in distilled water at 37℃ for 1 day and 7 days.
The color characteristics (L*,a*,b*) of the specimens before and after exposure of xenon lamp were measured by spectrophotometer and the total color differences (ΔE*) were computed.
The results obtained were as follows:
In all groups except A1 shade of group III, the ΔE* values presented below 2.0, and group III showed the highest ΔE* values followed by group II and group I in a decreasing order(p<0.05).
In all shades and groups, the more the exposure time of xenon lamp and the lighter the shade were, the higher the tendency for discoloration (p<0.05).
The composite resins which was exposed to xenon lamp in the distilled water was more discolored than those in the air (p<0.05).
The major changes of composite resins which were exposed to xenon lamp in the air were an increase in yellowness through a positive shift of the b* value, and those in the distilled water were an increase in darkness and yellowness through a negative shift of the L* value and a positive shift of the b* value.
-
Shear bond strength of self-etching adhesives to dentin and sem analysis
-
Young-Gon Cho, Kee-Sun Roh, Soo-Mee Kim, Young-Gon Lee, Jin-Ho Jeong, Young-Jae Ki
-
J Korean Acad Conserv Dent 2003;28(3):222-231. Published online May 31, 2003
-
DOI: https://doi.org/10.5395/JKACD.2003.28.3.222
-
-
Abstract
PDFPubReaderePub
The purpose of this study was to compare shear bond strength and interfacial pattern of composite bonded to dentin using self-etching adhesive systems.
Sixty extracted human molars with exposed occlusal dentin were divided into four groups and bonded with four adhesives and composites: Single Bond/Filtek Z 250(SB), Tyrian SPE-One-Step Plus/Aelitefil(TY), Prompt L-Pop/Filtek Z 250(LP), and One-Up Bond F/Palfique Toughwell(OU).
The results of this study were as follows;
Shear bond strength for OU was significantly lower than that of other groups(p<0.05). No significant difference was founded among SB, TY, and LP.
Failure modes to dentin showed adhesive and mixed for SB, TY, and LP, but them for OU showed adhesive in all spceimens.
Dentin-resin interface showed close adaptation for SB, TY, and LP, but it showed gap for OU.
The hybrid layers for TY, LP, OU were thinner than that of SB. Adhesive layers were observed between composite and hybrid layer, which were 5 µm thick for TY and 10 µm thick for OU.
-
Morphological patterns of self-etching primers and self-etching adhesive bonded to tooth structure
-
Young-Gon Cho, Seok-Jong Lee, Jin-Ho Jeong, Young-Gon Lee, Soo-Mee Kim
-
J Korean Acad Conserv Dent 2003;28(1):23-33. Published online January 31, 2003
-
DOI: https://doi.org/10.5395/JKACD.2003.28.1.023
-
-
Abstract
PDFPubReaderePub
The purpose of this study was to compare in vitro interfacial relationship of restorations bonded with three self-etching primer adhesives and one self-etching adhesive.
Class I cavity preparations were prepared on twenty extracted human molars. Prepared teeth were divided into four groups and restored with four adhesives and composites: Clearfil SE Bond/Clearfil™ AP-X (SE), UniFil Bond/UniFil® F (UF), FL Bond/Filtek™ Z 250 (FL) and Prompt L-Pop/Filtek™ Z 250 (LP)
After storing in distilled water of room temperature for 24 hours, the specimens were vertically sectioned and decalcified. Morphological patterns between the enamel/dentin and adhesives were observed under SEM.
The results of this study were as follows;
1. They showed close adaptation between enamel and SE, UF and FL except for LP.
2. The hybrid layer in dentin was 2 µm thick in SE, 1.5 µm thick in UF, and 0.4 µm in both FL and LP. So, the hybrid layers of SE and UF were slightly thicker than that of FL and LP.
3. The lengths and diameters of resin tags in UF and FL were similar, but those of LP were slightly shorter and slenderer than those of SE.
4. The resin tags were long rod shape in SE, and funnel shape in other groups.
Within the limitations of this study, it was concluded that self-etching primer adhesives showed close adaptation on enamel. In addition, the thickness of hybrid layer ranged from 0.4-1.5 µm between adhesives and dentin. The resin tags were long rod or funnel shape, and dimension of them was similar or different among adhesives.
|