Skip Navigation
Skip to contents

Restor Dent Endod : Restorative Dentistry & Endodontics

OPEN ACCESS

Search

Page Path
HOME > Search
4 "ProGlider"
Filter
Filter
Article category
Keywords
Publication year
Authors
Research Articles
Cyclic fatigue resistance of the WaveOne Gold Glider, ProGlider, and the One G glide path instruments in double-curvature canals
Damla Kırıcı, Alper Kuştarcı
Restor Dent Endod 2019;44(4):e36.   Published online September 9, 2019
DOI: https://doi.org/10.5395/rde.2019.44.e36
AbstractAbstract PDFPubReaderePub
Objectives

The aim of this study was to compare the cyclic fatigue resistance of the WaveOne Gold Glider, ProGlider and One G glide path instruments in artificial double-curvature canals.

Materials and Methods

This study included 15 WaveOne Gold Glider (size 15/0.08), 15 ProGlider (size 16/0.08), and 15 One G (size 16/0.06) nickel titanium files. The files were used in accordance with the manufacturer's instructions until they were broken in artificial double-curvature canals made of stainless steel. The time to fracture was recorded via a digital stopwatch and the number of rotations until fracture was also calculated. The data were statistically analyzed via the Kruskal-Wallis test.

Results

The highest average number of rotations until fracture of the files was found for the WaveOne Gold Glider, followed by ProGlider and One G in order. Statistically significant differences were present between all groups of files (p < 0.05).

Conclusions

In our study, the resistance of the WaveOne Gold Glider nickel-titanium (Ni-Ti) file to cyclic fatigue in S-shaped curved canals was found to be higher than that of the ProGlider and One G Ni-Ti files.

Citations

Citations to this article as recorded by  
  • Glide Path in Endodontics: A Literature Review of Current Knowledge
    Vlad Mircea Lup, Giulia Malvicini, Carlo Gaeta, Simone Grandini, Gabriela Ciavoi
    Dentistry Journal.2024; 12(8): 257.     CrossRef
  • In Vitro Evaluation of the Dynamic Cyclic Fatigue Resistance of a New TruNatomy Glider File after Different Cycles of Use
    Lorena Ferreira Rego, Juliana Delatorre Bronzato, Alana Pinto Carôso Souza, Adriana de-Jesus-Soares, Marcos Frozoni
    Journal of Endodontics.2024; 50(5): 619.     CrossRef
  • Comparative Evaluation of the Cyclic Fatigue Resistance of WaveOne Gold in Reciprocation, ProGlider in Rotary Motion, and Manual Files in a Reciprocating Handpiece Within Simulated Curved Canals: An In Vitro Study
    Shivangi M Pujara, Hardik B Shah, Leena H Jobanputra
    Cureus.2024;[Epub]     CrossRef
  • Comparative analysis of torsional and cyclic fatigue resistance of ProGlider, WaveOne Gold Glider, and TruNatomy Glider in simulated curved canal
    Pedro de Souza Dias, Augusto Shoji Kato, Carlos Eduardo da Silveira Bueno, Rodrigo Ricci Vivan, Marco Antonio Hungaro Duarte, Pedro Henrique Souza Calefi, Rina Andréa Pelegrine
    Restorative Dentistry & Endodontics.2023;[Epub]     CrossRef
  • Negotiability of mesiobuccal canals in maxillary first molars using different path file systems
    Maryam Gharechahi, Mandana Khajehpour, Ali Hamedi, Maryam Peighoun
    Dental Research Journal.2023;[Epub]     CrossRef
  • Cyclic Fatigue Resistance of Glide Path Rotary Files: A Systematic Review of in Vitro Studies
    Israa Ashkar, José Luis Sanz, Leopoldo Forner
    Materials.2022; 15(19): 6662.     CrossRef
  • Evaluation of design, mechanical properties, and torque/force generation of heat-treated NiTi glide path instruments
    Soram Oh, Ji-Yeon Seo, Ji-Eun Lee, Hyun-Jung Kim, Ji-Hyun Jang, Seok Woo Chang
    BMC Oral Health.2022;[Epub]     CrossRef
  • Body temperature fatigue behaviour of reciprocating and rotary glide path instruments in sodium hypochlorite solutions alone or combined with etidronate
    Dario Perez‐Villalba, José C. Macorra, Juan J. Perez‐Higueras, Ove A. Peters, Ana Arias
    Australian Endodontic Journal.2021; 47(3): 450.     CrossRef
  • 224 View
  • 3 Download
  • 8 Crossref
Close layer
Effect of glide path preparation with PathFile and ProGlider on the cyclic fatigue resistance of WaveOne nickel-titanium files
Gülşah Uslu, Uğur İnan
Restor Dent Endod 2019;44(2):e22.   Published online May 9, 2019
DOI: https://doi.org/10.5395/rde.2019.44.e22
AbstractAbstract PDFPubReaderePub
Objectives

The aim of this study was to investigate the effect of glide path preparation with PathFile and ProGlider nickel-titanium (NiTi) files on the cyclic fatigue resistance of WaveOne NiTi files.

Materials and Methods

Forty-four WaveOne Primary files were used and divided into four groups (n = 11). In the first group (0 WaveOne), the WaveOne Primary files served as a control group and were not used on acrylic blocks. In the 1 WaveOne Group, acrylic blocks were prepared using only WaveOne Primary files, and in the PF+WaveOne group and PG+WaveOne groups, acrylic blocks were first prepared with PathFile or ProGlider NiTi files, respectively, followed by the use of WaveOne Primary files. All the WaveOne Primary files were then subjected to cyclic fatigue testing. The number of cycles to failure was calculated and the data were statistically analyzed using one-way analysis of variance (ANOVA) and the Tukey honest significant difference multiple-comparison test at a 5% significance level.

Results

The highest number of cycles to failure was found in the control group, and the lowest numbers were found in the 1 WaveOne group and the PF+WaveOne group. Significant differences were found among the 1 WaveOne, PF+WaveOne, and control groups (p < 0.05). No statistically significant differences were found between the PG+WaveOne group and the other three groups (p > 0.05).

Conclusion

Glide path preparation with NiTi rotary files did not affect the cyclic fatigue resistance of WaveOne Primary files used on acrylic blocks.

Citations

Citations to this article as recorded by  
  • Screw-in force, torque generation, and performance of glide-path files with three rotation kinetics
    Jee-Yeon Woo, Ji-Hyun Jang, Seok Woo Chang, Soram Oh
    Odontology.2024; 112(3): 761.     CrossRef
  • Glide Path in Endodontics: A Literature Review of Current Knowledge
    Vlad Mircea Lup, Giulia Malvicini, Carlo Gaeta, Simone Grandini, Gabriela Ciavoi
    Dentistry Journal.2024; 12(8): 257.     CrossRef
  • Comparative Evaluation of the Cyclic Fatigue Resistance of WaveOne Gold in Reciprocation, ProGlider in Rotary Motion, and Manual Files in a Reciprocating Handpiece Within Simulated Curved Canals: An In Vitro Study
    Shivangi M Pujara, Hardik B Shah, Leena H Jobanputra
    Cureus.2024;[Epub]     CrossRef
  • Effect of glide path instruments in cyclic fatigue resistance of reciprocating instruments after three uses
    André Schroder Scherer, Carlos Alexandre Souza Bier, José Roberto Vanni
    Brazilian Dental Journal.2023; 34(2): 27.     CrossRef
  • An Investigation of the Accuracy and Reproducibility of 3D Printed Transparent Endodontic Blocks
    Martin Smutný, Martin Kopeček, Aleš Bezrouk
    Acta Medica (Hradec Kralove, Czech Republic).2022; 65(2): 59.     CrossRef
  • Evaluation of Cyclic Fatigue of Hyflex EDM, Twisted Files, and ProTaper Gold Manufactured with Different Processes: An In Vitro Study
    Pooja D. Khandagale, Prashant P. Shetty, Saleem D. Makandar, Pradeep A. Bapna, Mohmed Isaqali Karobari, Anand Marya, Pietro Messina, Giuseppe Alessandro Scardina, Antonino Lo Giudice
    International Journal of Dentistry.2021; 2021: 1.     CrossRef
  • 217 View
  • 4 Download
  • 6 Crossref
Close layer
In vitro comparison of the cyclic fatigue resistance of HyFlex EDM, One G, and ProGlider nickel titanium glide path instruments in single and double curvature canals
Koray Yılmaz, Gülşah Uslu, Taha Özyürek
Restor Dent Endod 2017;42(4):282-289.   Published online October 30, 2017
DOI: https://doi.org/10.5395/rde.2017.42.4.282
AbstractAbstract PDFPubReaderePub
Objectives

It was aimed to compare the cyclic fatigue resistances of ProGlider (PG), One G (OG), and HyFlex EDM (HEDM) nickel titanium glide path files in single- and double-curved artificial canals.

Materials and Methods

40 PG (16/0.02), 40 OG (14/0.03), and 40 HEDM (10/0.05) single-file glide path files were used in the present study. Sixty files were subjected to cyclic fatigue test by using double-curved canals and 60 files by using single-curved canal (n = 20). The number of cycles to fracture (NCF) was calculated and the length of the fractured fragment (FL) was determined by a digital micro-caliper. Twelve pieces of fractured files were examined with scanning electron microscope to determine fracture types of the files (n = 2). The NCF and the FL data were analyzed using one-way analysis of variance and post hoc Tukey test using SPSS 21 software (p < 0.05).

Results

In all of the groups, NCF values were significantly lower in double-curved canals when compared to single-curved canals (p < 0.05). For both of single- and double-curved canals, NCF values of HEDM group in apical and coronal curvatures were found to be significantly higher than NCF values of PG and OG groups (p < 0.05). In both of single- and double-curved canals, NCF value of PG group was found significantly higher than OG group (p < 0.05).

Conclusions

Within the limitations of this study, HEDM glide path files were found to have the highest cyclic fatigue resistance in both of single- and double-curved canals.

Citations

Citations to this article as recorded by  
  • The effect of canal curvature on cyclic fatigue resistance of rotary instruments using different irrigation materials (in vitro study)
    Mohammed Hamoudi Alsunboli, Sally Saad Ali Ihsan, Duha Qais Sabah
    F1000Research.2024; 12: 449.     CrossRef
  • Glide Path in Endodontics: A Literature Review of Current Knowledge
    Vlad Mircea Lup, Giulia Malvicini, Carlo Gaeta, Simone Grandini, Gabriela Ciavoi
    Dentistry Journal.2024; 12(8): 257.     CrossRef
  • Static and Dynamic Cyclic Fatigue Resistance of Nickel-Titanium Rotary Instruments in a Double-Curved Stainless Steel Artificial Canal
    Hoang-Lan-Anh Le, Thuan-Loc Tran, Thu-Thuy Nguyen, Tran-Lan-Khue Pham, Van-Khoa Pham
    Applied Sciences.2023; 13(4): 2687.     CrossRef
  • The effect of canal curvature on cyclic fatigue resistance of rotary instruments using different irrigation materials (in vitro study)
    Mohammed Hamoudi Alsunboli, Sally Saad Ali Ihsan, Duha Qais Sabah
    F1000Research.2023; 12: 449.     CrossRef
  • Comparative analysis of torsional and cyclic fatigue resistance of ProGlider, WaveOne Gold Glider, and TruNatomy Glider in simulated curved canal
    Pedro de Souza Dias, Augusto Shoji Kato, Carlos Eduardo da Silveira Bueno, Rodrigo Ricci Vivan, Marco Antonio Hungaro Duarte, Pedro Henrique Souza Calefi, Rina Andréa Pelegrine
    Restorative Dentistry & Endodontics.2023;[Epub]     CrossRef
  • Investigation of the efficacy of different Ni-Ti systems on acrylic blocks for correcting ledge formation
    Osman Ünlü, Hüseyin Gürkan Güneç, Faruk Haznedaroğlu
    BMC Oral Health.2023;[Epub]     CrossRef
  • Comparison of postoperative pain in single visit endodontics using heat-treated nickel − titanium file systems – A randomized clinical trial
    Priyanka Unnikrishnan, Lalitagauri Mandke, Leena Padhye
    Endodontology.2023; 35(2): 94.     CrossRef
  • Cyclic Fatigue Resistance of Glide Path Rotary Files: A Systematic Review of in Vitro Studies
    Israa Ashkar, José Luis Sanz, Leopoldo Forner
    Materials.2022; 15(19): 6662.     CrossRef
  • Endodontic Management of Dilacerated Maxillary First Molar with Tactile Controlled Activation Technique – A Case Report
    Vijay Yadav, Rega Kumar, Ruchika Roongta Nawal, Sangeeta Talwar
    Journal of Pierre Fauchard Academy (India Section).2022; : 67.     CrossRef
  • Combination of a new ultrasonic tip with rotary systems for the preparation of flattened root canals
    Karina Ines Medina Carita Tavares, Jáder Camilo Pinto, Airton Oliveira Santos-Junior, Fernanda Ferrari Esteves Torres, Juliane Maria Guerreiro-Tanomaru, Mario Tanomaru-Filho
    Restorative Dentistry & Endodontics.2021;[Epub]     CrossRef
  • Cyclic Fatigue of TruNatomy Nickel-Titanium Rotary Instrument in Single and Double Curvature Canals: A Comparative Study
    Sarah A Rashid, Hikmet A AI-Gharrawi
    World Journal of Dentistry.2021; 12(1): 28.     CrossRef
  • Micro-computed tomographic evaluation of a new system for root canal filling using calcium silicate-based root canal sealers
    Mario Tanomaru-Filho, Fernanda Ferrari Esteves Torres, Jader Camilo Pinto, Airton Oliveira Santos-Junior, Karina Ines Medina Carita Tavares, Juliane Maria Guerreiro-Tanomaru
    Restorative Dentistry & Endodontics.2020;[Epub]     CrossRef
  • Comparison of torque, force generation and canal shaping ability between manual and nickel-titanium glide path instruments in rotary and optimum glide path motion
    Pyae Hein Htun, Arata Ebihara, Keiichiro Maki, Shunsuke Kimura, Miki Nishijo, Daisuke Tokita, Takashi Okiji
    Odontology.2020; 108(2): 188.     CrossRef
  • Torsional fatigue strength of reciprocating and rotary pathfinding instruments manufactured from different NiTi alloys
    Rodrigo Ricci VIVAN, Murilo Priori ALCALDE, George CANDEIRO, Giulio GAVINI, Celso Luis CALDEIRA, Marco Antonio Hungaro DUARTE
    Brazilian Oral Research.2019;[Epub]     CrossRef
  • Comparison of postoperative pain intensity after using reciprocating and continuous rotary glide path systems: a randomized clinical trial
    Mehmet Adıgüzel, Koray Yılmaz, Pelin Tüfenkçi
    Restorative Dentistry & Endodontics.2019;[Epub]     CrossRef
  • Cyclic fatigue resistance of the WaveOne Gold Glider, ProGlider, and the One G glide path instruments in double-curvature canals
    Damla Kırıcı, Alper Kuştarcı
    Restorative Dentistry & Endodontics.2019;[Epub]     CrossRef
  • Intraoperative Pain During Glide Path Creation with the Use of a Rotary or Reciprocating System
    Pelin TUFENKCİ, Mehmet ADIGUZEL, Koray YILMAZ
    Cumhuriyet Dental Journal.2019; 22(1): 66.     CrossRef
  • 213 View
  • 0 Download
  • 17 Crossref
Close layer
Influence of a glide path on the dentinal crack formation of ProTaper Next system
Sevinç Aktemur Türker, Emel Uzunoğlu
Restor Dent Endod 2015;40(4):286-289.   Published online September 2, 2015
DOI: https://doi.org/10.5395/rde.2015.40.4.286
AbstractAbstract PDFPubReaderePub
Objectives

The aim was to evaluate dentinal crack formation after root canal preparation with ProTaper Next system (PTN) with and without a glide path.

Materials and Methods

Forty-five mesial roots of mandibular first molars were selected. Fifteen teeth were left unprepared and served as controls. The experimental groups consist of mesiobuccal and mesiolingual root canals of remaining 30 teeth, which were divided into 2 groups (n = 15): Group PG/PTN, glide path was created with ProGlider (PG) and then canals were shaped with PTN system; Group PTN, glide path was not prepared and canals were shaped with PTN system only. All roots were sectioned perpendicular to the long axis at 1, 2, 3, 4, 6, and 8 mm from the apex, and the sections were observed under a stereomicroscope. The presence/absence of cracks was recorded. Data were analyzed with chi-square tests with Yates correction.

Results

There were no significant differences in crack formation between the PTN with and without glide path preparation. The incidence of cracks observed in PG/PTN and PTN groups was 17.8% and 28.9%, respectively.

Conclusions

The creation of a glide path with ProGlider before ProTaper Next rotary system did not influence dentinal crack formation in root canals.

Citations

Citations to this article as recorded by  
  • Glide Path in Endodontics: A Literature Review of Current Knowledge
    Vlad Mircea Lup, Giulia Malvicini, Carlo Gaeta, Simone Grandini, Gabriela Ciavoi
    Dentistry Journal.2024; 12(8): 257.     CrossRef
  • Comparative Evaluation of the Shaping Ability of the Recent, Fifth-generation ProTaper Next and Revo-S NiTi Rotary Endodontic Files Using Three-dimensional Imaging: An Imaging-based Study
    Prajna Pattanaik, Akilan Balasubramanian, P. Veeralakshmi, Gautam Singh, Vandana Sadananda, Hina Ahmed, J. Suresh Babu, C. Swarnalatha, Abhishek Singh Nayyar
    Journal of Microscopy and Ultrastructure.2023;[Epub]     CrossRef
  • Microscopic Assessment of Dentinal Defects Induced by ProTaper Universal, ProTaper Gold, and Hyflex Electric Discharge Machining Rotary File Systems – An in vitro Study
    Takhellambam Premlata Devi, Amandeep Kaur, Shamurailatpam Priyadarshini, B. S. Deepak, Sumita Banerjee, Ng Sanjeeta
    Contemporary Clinical Dentistry.2021; 12(3): 230.     CrossRef
  • Influence of Negotiation, Glide Path, and Preflaring Procedures on Root Canal Shaping—Terminology, Basic Concepts, and a Systematic Review
    Gianluca Plotino, Venkateshbabu Nagendrababu, Frederic Bukiet, Nicola M. Grande, Sajesh K. Veettil, Gustavo De-Deus, Hany Mohamed Aly Ahmed
    Journal of Endodontics.2020; 46(6): 707.     CrossRef
  • 207 View
  • 3 Download
  • 4 Crossref
Close layer

Restor Dent Endod : Restorative Dentistry & Endodontics
Close layer
TOP