Warning: mkdir(): Permission denied in /home/virtual/lib/view_data.php on line 81

Warning: fopen(upload/ip_log/ip_log_2024-12.txt): failed to open stream: No such file or directory in /home/virtual/lib/view_data.php on line 83

Warning: fwrite() expects parameter 1 to be resource, boolean given in /home/virtual/lib/view_data.php on line 84
In vitro comparison of the cyclic fatigue resistance of HyFlex EDM, One G, and ProGlider nickel titanium glide path instruments in single and double curvature canals
Skip Navigation
Skip to contents

Restor Dent Endod : Restorative Dentistry & Endodontics

OPEN ACCESS

Articles

Page Path
HOME > Restor Dent Endod > Volume 42(4); 2017 > Article
Research Article In vitro comparison of the cyclic fatigue resistance of HyFlex EDM, One G, and ProGlider nickel titanium glide path instruments in single and double curvature canals
Koray Yılmaz1orcid, Gülşah Uslu2orcid, Taha Özyürek2orcid
Restorative Dentistry & Endodontics 2017;42(4):282-289.
DOI: https://doi.org/10.5395/rde.2017.42.4.282
Published online: October 30, 2017

orum Oral and Dental Health Center, Çorum, Turkey.

2Department of Endodontics, Ondokuz Mayıs University Faculty of Dentistry, Samsun, Turkey.

Correspondence to Taha Özyürek, DDS, PhD. Research Assistant, Department of Endodontics, Ondokuz Mayıs University Faculty of Dentistry, Atakum, Samsun 55139, Turkey. Tel: +90-505-260-2749, Fax: +90-362-457-3062, tahaozyurek@hotmail.com
• Received: April 24, 2017   • Accepted: September 3, 2017

Copyright © 2017. The Korean Academy of Conservative Dentistry

This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

  • 22 Views
  • 0 Download
prev next
  • Objectives
    It was aimed to compare the cyclic fatigue resistances of ProGlider (PG), One G (OG), and HyFlex EDM (HEDM) nickel titanium glide path files in single- and double-curved artificial canals.
  • Materials and Methods
    40 PG (16/0.02), 40 OG (14/0.03), and 40 HEDM (10/0.05) single-file glide path files were used in the present study. Sixty files were subjected to cyclic fatigue test by using double-curved canals and 60 files by using single-curved canal (n = 20). The number of cycles to fracture (NCF) was calculated and the length of the fractured fragment (FL) was determined by a digital micro-caliper. Twelve pieces of fractured files were examined with scanning electron microscope to determine fracture types of the files (n = 2). The NCF and the FL data were analyzed using one-way analysis of variance and post hoc Tukey test using SPSS 21 software (p < 0.05).
  • Results
    In all of the groups, NCF values were significantly lower in double-curved canals when compared to single-curved canals (p < 0.05). For both of single- and double-curved canals, NCF values of HEDM group in apical and coronal curvatures were found to be significantly higher than NCF values of PG and OG groups (p < 0.05). In both of single- and double-curved canals, NCF value of PG group was found significantly higher than OG group (p < 0.05).
  • Conclusions
    Within the limitations of this study, HEDM glide path files were found to have the highest cyclic fatigue resistance in both of single- and double-curved canals.
A new era has begun in endodontics with the development of nickel titanium (NiTi) files in 1980s [1]. The mechanical features of NiTi files grant the flexibility to the files, and provide convenience in preparation of curved canals [2]. Despite this advantage and all the conveniences that NiTi files offer, the most important disadvantage is that they can unexpectedly fracture. These fractures occur as a result of torsional or cyclic fatigue [3]. The cyclic fatigue fractures occur as a result of the repetitive compression and tension stresses that the file is exposed to within the curved canals. On the other hand, the torsional fractures occur as a result of the continuance of rotation of coronal part of the file, while the tip or a part of file is stuck in the canal [3,4].
The concept of glide path, which is defined as the space from the orifice to the apex, is of significant importance for safely shaping the root canals [5,6]. Together with the advances in manufacturing methods and metallurgy, many NiTi rotary glide path files were introduced to the market to facilitate the formation of glide path. ProGlider (PG; Dentsply Maillefer, Ballaigues, Switzerland) and One G (OG; Micro-Mega, Besancon, France) are the single file systems developed for the glide path. PG is made of M-Wire alloy that has been developed via the special thermal methods in order to improve cyclic fatigue resistance and flexibility of NiTi alloys [7]. Moreover, different from other glide path files, PG has 0.16 mm of tip diameter, taper varying between 2%–8% through the shaft, and 4 cutting edges with square cross-section [8]. OG has 0.14 mm of tip diameter and 3% taper that is constant throughout the shaft. The file has 3 cutting edges with asymmetric cross-section. The manufacturer claims that the cutting edges having different radii provide better debris elimination [9].
Recently introduced HyFlex EDM (HEDM; Coltene/Whaledent AG, Altstätten, Switzerland) NiTi files are manufactured using the technique of electrical discharge machining (EDM) with controlled-memory feature. When compared to HyFlex CM (Coltene/Whaledent AG) file, the manufacturer claims that this method offer up to 700% higher cyclic fatigue resistance [10]. HEDM glide path file has 0.10 mm diameter and 5% taper throughout the shaft. The file has 3 different cross-sections along the shaft; quadratic in apical, trapezoidal in middle and triangular in coronal.
In comprehensive literature review, no study examining the cyclic fatigue resistances of PG, OG, and HEDM glide path files in double-curved (S-shaped) artificial canals was found. For this reason, the objective of present study was to compare the cyclic fatigue resistances of PG, OG, and HEDM NiTi glide path files in single- and double-curved artificial canals in static cyclic fatigue testing model. The null hypothesis was that there would be no statistical difference between the files' cyclic fatigue resistance under static model in single- and double-curved canals.
Forty PG (16/0.02), 40 OG (14/0.03), and 40 HEDM (10/0.05) single-file glide path files were included in the present study. Sixty files (n = 20/each group) were subjected to cyclic fatigue testing by using double-curved artificial canal. The double-curved artificial canals' first coronal curve has 60° angle of curvature with 5 mm radius and the center of the curvature was located 8 mm distant from the tip of the canal, while the second apical curve has 70° angle of curvature with a radius of 2 mm and the center of the curvature located 2 mm distant from the tip of the canal as in previous studies [11,12,13]. The working length of the artificial canal was 18 mm and its inner diameter was 1.5 mm (Figure 1).
Figure 1
Artificial canal with double curvature that used in the present study.
rde-42-282-g001.jpg
Sixty files (n = 20/each group) were subjected to cyclic fatigue testing by using single-curved artificial canal. The single-curved artificial canal has 60° angle of curvature with 5 mm radius, 1.5 mm inner diameter and the center of the curvature was located 5 mm distant from the tip of the canal. The working length of artificial canal was 17 mm (Figure 2).
Figure 2
Artificial canal with single curvature that used in the present study.
rde-42-282-g002.jpg
All the instruments were operated using a torque-controlled endodontic motor (VDW Gold, VDW, Munich, Germany) and were used according to the manufacturers' recommendations as follows: PG at 300 revolutions per minute (rpm) and 200 gcm−1 torque, HEDM at 300 rpm and 1.8 gcm−1 torque, and OG at 300 rpm and 1.2 gcm−1 torque. In order to minimize the friction between the files and the artificial canals, the synthetic lubricant (WD Company, Milton Keynes, UK) was used. The number of cycles to fracture (NCF) for each file was calculated with formula:
NCF = rpm × Time to fracture (seconds)/60
The fracture length (FL) of the apical part was calculated by measuring the fractured tip directly. However, the FL of the coronal fragment was calculated by subtraction the remaining length of the file from the total length. In the measurement, a digital micro-caliper was used using ImageJ software (National Institutes of Health, Bethesda, MD, USA).
A total of 12 pieces of fractured files, 2 pieces from each group, was examined with a scanning electron microscope (SEM; JSM-7001F, JEOL, Tokyo, Japan) to determine fracture types of the files, and photomicrographs were taken from the fractured surfaces under different magnifications. From the SEM images, the cross-sectional areas of the fractured surfaces were calculated.
Statistical analyses
The NCF and the FL data were analyzed by using one-way analysis of variance (ANOVA) and post hoc Tukey tests. The apical and coronal comparison was performed using Student's t-test. All of the analyses were performed using SPSS 21 software (IBM-SPSS Inc., Chicago, IL, USA), and the statistical significance level was set at 5%.
The mean NCF and FL values and standard deviations of the files are presented in Table 1. In double-curved canals, all of the files fractured firstly in apical curvature and then in coronal curvature. In double-curved canals, the apical curvature NCF values of all of the groups were significantly lower than coronal curvature NCF values (p < 0.05). For both of single- and double-curved canals, NCF value of HEDM group was significantly higher than NCF values of PG and OG groups (p < 0.05). Moreover, in both of single- and double-curved canals, NCF value of PG group was significantly higher than in OG group (p < 0.05).
Table 1

The number of cycles to failure and length (mm) of fractured fragments of instruments during cyclic fatigue testing in double and single curvature

Group No. Double curvature Single curvature
Coronal curvature Apical curvature
NCF FL NCF FL NCF FL
One G 20 470.21 ± 152.76aA 6.72 ± 1.67a 395.63 ± 139.05aA 2.08 ± 0.34a 846.94 ± 274.96a 5.43 ± 1.39a
ProGlider 20 1,020.28 ± 375.34bA 6.03 ± 1.05a 961.87 ± 293.45bA 2.11 ± 0.56a 1,614.65 ± 601.42b 4.93 ± 1.02a
HyFlex EDM 20 2,458.32 ± 538.65cA 6.68 ± 1.39a 1,966.46 ± 412.43cB 2.24 ± 0.64a 3,441.24 ± 961.84c 5.25 ± 1.22a
p value - < 0.05 > 0.05 < 0.05 > 0.05 < 0.05 > 0.05
Manufacturer information is follow as; One G, Micro-Mega, Besancon, France; ProGlider, Dentsply Maillefer, Ballaigues, Switzerland; HyFlex EDM, Coltene/Whaledent AG, Altstätten, Switzerland. Different superscripts indicate statistically significant difference at 0.05 (a,b,cfor columns; A,Bfor rows).
NCF, number of cycles to fracture; FL, legnth of fracture.
The mean FL was also recorded to evaluate the correct positioning of the tested instrument inside the canal curvature and whether similar stresses were being induced. No statistically significant difference in the mean FL was evident for the instruments (Table 1).
SEM analysis of the fractured cross-sectional surfaces revealed typical features of cyclic failure including crack origins, fatigue zone, and an overload fast fracture zone (Figure 3). The areas of the fracture surface of the files were 0.11653 mm2 in HEDM group, 0.40172 mm2 in OG group, and 0.48452 mm2 in PG group.
Figure 3
Scanning electron microscopic appearances of the One G (OG), ProGlider (PG), and HyFlex EDM (HEDM) files after cyclic fatigue testing. View of the fractured surface (A) HEDM, (C) OG, and (E) PG and high-magnification view of (B) HEDM, (D) OG, and (F) PG instruments showing fatigue striations typical of cyclic fatigue (arrows).
One G, Micro-Mega, Besancon, France; ProGlider, Dentsply Maillefer, Ballaigues, Switzerland; HyFlex EDM, Coltene/Whaledent AG, Altstätten, Switzerland.
rde-42-282-g003.jpg
Glide path was shown to be capable of eliminating the complications that are observed during the root canal preparation process [14]. Together with the clinicians' increasing demand on single-file systems in order to make preparation easier, the single-file glide path systems were introduced to the market. PG, OG, and HEDM are the glide path files systems consisting of single file.
Many studies examining the NiTi files cyclic fatigue resistance were carried out on the artificial canals [15,16]. The aim of using artificial canals is to minimize the anatomic variation, which might arise from the natural teeth, and to ensure certain level of standardization. The angle and number of curvatures within the canal are among the most important factors testing the cyclic fatigue resistance of files [15]. Under the clinical conditions, 2 curvatures might exist in the same canal at the same time, and the canals having this geometry are defined as S-shaped canals. Moreover, the S-shaped canals, which are frequently missed out in conventional radiographies, lay the foundation of failures. When compared to single-curved canals, double-curved canals were reported to cause the decreases in cyclic fatigue resistance of files and the fracture to occur in shorter times [11]. In the literature, few studies on the cyclic fatigue of NiTi files were carried out on the double-curved canals [11,17]. In comprehensive literature review, no study examining the cyclic fatigue resistances of NiTi glide path files, which were tested in present study on double-curved artificial canals, was found. For this reason, it was aimed to compare the cyclic fatigue resistances of glide path files in single- and double-curved artificial canals. According to the results of present study, it was determined that, when used at torque and speed settings recommended by the manufacturers, NCF values of HEDM files in both of single- and double-curved canals' apical and coronal sections were statistically significantly higher than PG and OG files. For this reason, the null hypothesis was rejected.
Some of the factors influencing the cyclic fatigue resistances of NiTi files are the type of alloy [18] that the files are manufactured and the application of heat treatment on the NiTi files [19,20]. According to the results of present study, cyclic fatigue resistance of HEDM glide path files made of controlled memory (CM) alloy with EDM treatment had significantly higher cyclic fatigue resistance than PG made of M-Wire alloy and OG glide path files made of conventional NiTi alloy. Difference among the groups might be related to the manufacturing procedures that the files made. Conventional NiTi alloys are in the austenite phase at mouth and room temperatures. At room temperature, the CM alloys exist in both austenite and martensite phases because the martensite is softer than austenite, and the higher martensite content of files made of CM alloy has a positive effect on their cyclic fatigue resistance [21]. Capar et al. [22] compared the cyclic fatigue resistances of PathFile (Dentsply Maillefer), G-File (Micro-Mega), Scout Race (FKG Dentaire, La Chaux-de-Fonds, Switzerland), HyFlex GPF (Coltene/Whaledent AG), and PG glide path files. The authors reported that the highest cyclic fatigue resistance was found in HyFlex GPF group, and the authors attributed the difference to the difference between manufacturing methods and to the structural superiority of CM alloy. The previous studies on CM alloys corroborate this conclusion [23,24,25,26]. Moreover, similarly to the results of present study, Uslu et al. [27] reported the cyclic fatigue resistance of PG files to be higher than OG files. In a similar study, it was reported that the cyclic fatigue of NiTi files made of M-Wire alloy was 400% higher than the files made of conventional NiTi alloy [28].
The results of present study indicated that the duration and NCF decreased together with the increase in the amount and complexity of curvatures within the canal. The present results show similarities with the previous studies examining the effects of canal complexity on the file fractures [15,16]. Moreover, Al-Sudani et al. [11], Shen et al. [29], and Topçuoğlu et al. [17] corroborated this conclusion in their studies on double-curved canals.
Considering all the files employed in present study, the data obtained indicate that, in double-curved canals, the cyclic fatigue resistance of files in apical curvature is lower than the resistance in coronal curvature. We believe that this originates from the higher angle of apical curvature (70°) in proportion to the angle of coronal curvature (60°) and much lower radii of apical curvature (2 mm) in proportion to the radii of coronal curvature (5 mm). Regardless of the differences between the files used in present study, it can be stated that the anatomies of double-curved canals may cause lower NCF of files by leading to higher level of stress accumulation than in single-curved canals.
It is difficult to make comparison among different brands because of the differences between their designs, cross-sectional areas, and types of alloy used. Moreover, in clinic use, different irrigation solutions and usage forces may affect the cyclic fatigue resistance of the tested files. Thus the results of the present study should be applied to clinic carefully.
Within the limitations of present study, HEDM glide path files were found to have the highest cyclic fatigue resistance in both of single- and double-curved canals. Moreover, the cyclic fatigue resistances of all the glide path files tested in present study were found to be lower in double-curved canals than in single-curved canals.

Conflict of Interest: No potential conflict of interest relevant to this article was reported.

Author Contributions:

  • Conceptualization: Yılmaz K, Uslu G, Özyürek T

  • Data curation: Uslu G, Özyürek T.

  • Formal analysis: Özyürek T.

  • Funding acquisition: Yılmaz K, Uslu G, Özyürek T.

  • Investigation: Özyürek T.

  • Methodology: Yılmaz K, Uslu G, Özyürek T.

  • Project administration: Özyürek T.

  • Resources: Yılmaz K, Uslu G, Özyürek T.

  • Supervision: Özyürek T.

  • Validation: Özyürek T.

  • Visualization: Özyürek T, Uslu G.

  • Writing - original draft: Yılmaz K, Uslu G.

  • Writing - review & editing: Özyürek T.

  • 1. Peters OA. Current challenges and concepts in the preparation of root canal systems: a review. J Endod 2004;30:559-567. PubMed
  • 2. Walia HM, Brantley WA, Gerstein H. An initial investigation of the bending and torsional properties of Nitinol root canal files. J Endod 1988;14:346-351. ArticlePubMed
  • 3. Sattapan B, Nervo GJ, Palamara JE, Messer HH. Defects in rotary nickel-titanium files after clinical use. J Endod 2000;26:161-165. ArticlePubMed
  • 4. Cheung GS. Instrument fracture: mechanisms, removal of fragments, and clinical outcomes. Endod Topics 2007;16:1-26.Article
  • 5. Patiño PV, Biedma BM, Liébana CR, Cantatore G, Bahillo JG. The influence of a manual glide path on the separation rate of NiTi rotary instruments. J Endod 2005;31:114-116. PubMed
  • 6. Ha JH, Park SS. Influence of glide path on the screw-in effect and torque of nickel-titanium rotary files in simulated resin root canals. Restor Dent Endod 2012;37:215-219. ArticlePubMedPMC
  • 7. Gambarini G, Grande NM, Plotino G, Somma F, Garala M, De Luca M, Testarelli L. Fatigue resistance of engine-driven rotary nickel-titanium instruments produced by new manufacturing methods. J Endod 2008;34:1003-1005. ArticlePubMed
  • 8. Dentsply. Pro·glider™. updated 2017 Jan 1]. Available from: http://www.dentsplymea.com/sites/default/files/211%20Proglider%20Brochure%20FINAL.pdf.
  • 9. Micro Mega. One G. updated 2017 Jan 1]. Available from: http://micro-mega.com/en/wp-content/uploads/2015/02/OneG_EN1_15_web.pdf.
  • 10. Coltene. HyFlex® EDM. updated 2017 Jan 1]. Available from: https://www.coltene.com/fileadmin/Data/EN/Products/Endodontics/Root_Canal_Shaping/HyFlex_EDM/31328A_HyFlexEDM_Brochure_US.pdf.
  • 11. Al-Sudani D, Grande NM, Plotino G, Pompa G, Di Carlo S, Testarelli L, Gambarini G. Cyclic fatigue of nickel-titanium rotary instruments in a double (S-shaped) simulated curvature. J Endod 2012;38:987-989. ArticlePubMed
  • 12. Neelakantan P, Reddy P, Gutmann JL. Cyclic fatigue of two different single files with varying kinematics in a simulated double-curved canal. J Investig Clin Dent 2016;7:272-277.PubMed
  • 13. Topçuoğlu HS, Düzgün S, Aktı A, Topçuoğlu G. Laboratory comparison of cyclic fatigue resistance of WaveOne Gold, Reciproc and WaveOne files in canals with a double curvature. Int Endod J 2017;50:713-717. ArticlePubMedPDF
  • 14. Berutti E, Cantatore G, Castellucci A, Chiandussi G, Pera F, Migliaretti G, Pasqualini D. Use of nickel-titanium rotary PathFile to create the glide path: comparison with manual preflaring in simulated root canals. J Endod 2009;35:408-412. ArticlePubMed
  • 15. Pruett JP, Clement DJ, Carnes DL Jr. Cyclic fatigue testing of nickel-titanium endodontic instruments. J Endod 1997;23:77-85. ArticlePubMed
  • 16. Plotino G, Grande NM, Sorci E, Malagnino VA, Somma F. A comparison of cyclic fatigue between used and new Mtwo Ni-Ti rotary instruments. Int Endod J 2006;39:716-723. PubMed
  • 17. Topçuoğlu HS, Topçuoğlu G, Akti A, Düzgün S. In vitro comparison of cyclic fatigue resistance of ProTaper Next, HyFlex CM, OneShape, and ProTaper Universal Instruments in a canal with a double curvature. J Endod 2016;42:969-971. ArticlePubMed
  • 18. Versluis A, Kim HC, Lee W, Kim BM, Lee CJ. Flexural stiffness and stresses in nickel-titanium rotary files for various pitch and cross-sectional geometries. J Endod 2012;38:1399-1403. ArticlePubMed
  • 19. Arias A, Perez-Higueras JJ, de la Macorra JC. Influence of clinical usage of GT and GTX files on cyclic fatigue resistance. Int Endod J 2014;47:257-263. PubMed
  • 20. Frick CP, Ortega AM, Tyber J, Maksound AE, Maier HJ, Liu Y, Gall K. Thermal processing of polycrystalline NiTi shape memory alloys. Mater Sci Eng A Struct Mater 2005;405:34-49.
  • 21. Braga LC, Faria Silva AC, Buono VT, de Azevedo Bahia MG. Impact of heat treatments on the fatigue resistance of different rotary nickel-titanium instruments. J Endod 2014;40:1494-1497. ArticlePubMed
  • 22. Capar ID, Kaval ME, Ertas H, Sen BH. Comparison of the cyclic fatigue resistance of 5 different rotary pathfinding instruments made of conventional nickel-titanium wire, M-wire, and controlled memory wire. J Endod 2015;41:535-538. ArticlePubMed
  • 23. Capar ID, Ertas H, Arslan H. Comparison of cyclic fatigue resistance of nickel-titanium coronal flaring instruments. J Endod 2014;40:1182-1185. ArticlePubMed
  • 24. Plotino G, Testarelli L, Al-Sudani D, Pongione G, Grande NM, Gambarini G. Fatigue resistance of rotary instruments manufactured using different nickel-titanium alloys: a comparative study. Odontology 2014;102:31-35. PubMed
  • 25. Pongione G, Pompa G, Milana V, Di Carlo S, Giansiracusa A, Nicolini E, De Angelis F. Flexibility and resistance to cyclic fatigue of endodontic instruments made with different nickel-titanium alloys: a comparative test. Ann Stomatol (Roma) 2012;3:119-122. PubMedPMC
  • 26. Capar ID, Ertas H, Arslan H. Comparison of cyclic fatigue resistance of novel nickel-titanium rotary instruments. Aust Endod J 2015;41:24-28. ArticlePubMed
  • 27. Uslu G, Özyürek T, İnan U. Comparison of cyclic fatigue resistance of ProGlider and One G glide path files. J Endod 2016;42:1555-1558. ArticlePubMed
  • 28. Johnson E, Lloyd A, Kuttler S, Namerow K. Comparison between a novel nickel-titanium alloy and 508 nitinol on the cyclic fatigue life of ProFile 25/.04 rotary instruments. J Endod 2008;34:1406-1409. PubMed
  • 29. Shen Y, Hieawy A, Huang X, Wang ZJ, Maezono H, Haapasalo M. Fatigue resistance of a 3-dimensional conforming nickel-titanium rotary instrument in double curvatures. J Endod 2016;42:961-964. ArticlePubMed

Tables & Figures

REFERENCES

    Citations

    Citations to this article as recorded by  

      • ePub LinkePub Link
      • Cite
        CITE
        export Copy Download
        Close
        Download Citation
        Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

        Format:
        • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
        • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
        Include:
        • Citation for the content below
        In vitro comparison of the cyclic fatigue resistance of HyFlex EDM, One G, and ProGlider nickel titanium glide path instruments in single and double curvature canals
        Restor Dent Endod. 2017;42(4):282-289.   Published online October 30, 2017
        Close
      • XML DownloadXML Download
      Figure
      • 0
      • 1
      • 2
      Related articles
      In vitro comparison of the cyclic fatigue resistance of HyFlex EDM, One G, and ProGlider nickel titanium glide path instruments in single and double curvature canals
      Image Image Image
      Figure 1 Artificial canal with double curvature that used in the present study.
      Figure 2 Artificial canal with single curvature that used in the present study.
      Figure 3 Scanning electron microscopic appearances of the One G (OG), ProGlider (PG), and HyFlex EDM (HEDM) files after cyclic fatigue testing. View of the fractured surface (A) HEDM, (C) OG, and (E) PG and high-magnification view of (B) HEDM, (D) OG, and (F) PG instruments showing fatigue striations typical of cyclic fatigue (arrows).One G, Micro-Mega, Besancon, France; ProGlider, Dentsply Maillefer, Ballaigues, Switzerland; HyFlex EDM, Coltene/Whaledent AG, Altstätten, Switzerland.
      In vitro comparison of the cyclic fatigue resistance of HyFlex EDM, One G, and ProGlider nickel titanium glide path instruments in single and double curvature canals

      The number of cycles to failure and length (mm) of fractured fragments of instruments during cyclic fatigue testing in double and single curvature

      GroupNo.Double curvatureSingle curvature
      Coronal curvatureApical curvature
      NCFFLNCFFLNCFFL
      One G20470.21 ± 152.76aA6.72 ± 1.67a395.63 ± 139.05aA2.08 ± 0.34a846.94 ± 274.96a5.43 ± 1.39a
      ProGlider201,020.28 ± 375.34bA6.03 ± 1.05a961.87 ± 293.45bA2.11 ± 0.56a1,614.65 ± 601.42b4.93 ± 1.02a
      HyFlex EDM202,458.32 ± 538.65cA6.68 ± 1.39a1,966.46 ± 412.43cB2.24 ± 0.64a3,441.24 ± 961.84c5.25 ± 1.22a
      p value-< 0.05> 0.05< 0.05> 0.05< 0.05> 0.05

      Manufacturer information is follow as; One G, Micro-Mega, Besancon, France; ProGlider, Dentsply Maillefer, Ballaigues, Switzerland; HyFlex EDM, Coltene/Whaledent AG, Altstätten, Switzerland. Different superscripts indicate statistically significant difference at 0.05 (a,b,cfor columns; A,Bfor rows).

      NCF, number of cycles to fracture; FL, legnth of fracture.

      Table 1 The number of cycles to failure and length (mm) of fractured fragments of instruments during cyclic fatigue testing in double and single curvature

      Manufacturer information is follow as; One G, Micro-Mega, Besancon, France; ProGlider, Dentsply Maillefer, Ballaigues, Switzerland; HyFlex EDM, Coltene/Whaledent AG, Altstätten, Switzerland. Different superscripts indicate statistically significant difference at 0.05 (a,b,cfor columns; A,Bfor rows).

      NCF, number of cycles to fracture; FL, legnth of fracture.


      Restor Dent Endod : Restorative Dentistry & Endodontics
      Close layer
      TOP