Warning: mkdir(): Permission denied in /home/virtual/lib/view_data.php on line 81

Warning: fopen(upload/ip_log/ip_log_2024-12.txt): failed to open stream: No such file or directory in /home/virtual/lib/view_data.php on line 83

Warning: fwrite() expects parameter 1 to be resource, boolean given in /home/virtual/lib/view_data.php on line 84
Physicochemical characterization of two bulk fill composites at different depths
Skip Navigation
Skip to contents

Restor Dent Endod : Restorative Dentistry & Endodontics

OPEN ACCESS

Articles

Page Path
HOME > Restor Dent Endod > Volume 46(3); 2021 > Article
Research Article Physicochemical characterization of two bulk fill composites at different depths
Guillermo Grazioli1orcid, Carlos Enrique Cuevas-Suárez2orcid, Leina Nakanishi3orcid, Alejandro Francia4orcid, Rafael Ratto de Moraes3orcid

DOI: https://doi.org/10.5395/rde.2021.46.e39
Published online: July 5, 2021

1Department of Dental Materials, School of Dentistry, Universidad de la República, Montevideo, Uruguay.

2Laboratory of Dental Materials, Academic Area of Dentistry, Autonomous University of Hidalgo State, Pachuca, México.

3Graduate Program in Dentistry, Federal University of Pelotas, Pelotas, Brazil.

4Department of General and Oral Physiology, School of Dentistry, Universidad de la República, Montevideo, Uruguay.

Correspondence to Gillermo Grazioli, DDS, PhD. Assistant Professor, Department of Dental Materials, School of Dentistry, Universidad de la República, General Las Heras 1925, Montevideo 11600, Uruguay. ggrazioli@odon.edu.uy
• Received: October 2, 2020   • Revised: January 14, 2021   • Accepted: January 21, 2021

Copyright © 2021. The Korean Academy of Conservative Dentistry

This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

  • 16 Views
  • 1 Download
  • 5 Web of Science
prev next
  • Objectives
    This study analyzed the physical-chemical behavior of 2 bulk fill resin composites (BFCs; Filtek Bulk Fill [FBF], and Tetric-N-Ceram Bulk Fill [TBF]) used in 2- and 4-mm increments and compared them with a conventional resin composite (Filtek Z250).
  • Materials and Methods
    Flexural strength and elastic modulus were evaluated by using a 3-point bending test. Knoop hardness was measured at depth areas 0–1, 1–2, 2–3, and 3–4 mm. The translucency parameter was measured using an optical spectrophotometer. Real-time polymerization kinetics was analyzed using Fourier transform infrared spectroscopy.
  • Results
    Flexural strength was similar among the materials, while TBF showed lower elastic modulus (Z250: 6.6 ± 1.3, FBF: 6.4 ± 0.9, TBF: 4.3 ± 1.3). The hardness of Z250 was similar only between 0–1 mm and 1–2 mm. Both BFCs had similar hardness until 2–3 mm, and showed significant decreases at 3–4 mm (FBF: 33.45 ± 1.95 at 0–1 mm to 23.19 ± 4.32 at 3–4 mm, TBF: 23.17 ± 2.51 at 0–1 mm to 15.11 ± 1.94 at 3–4 mm). The BFCs showed higher translucency than Z250. The polymerization kinetics of all the materials were similar at 2-mm increments. At 4-mm, only TBF had a similar degree of conversion compared with 2 mm.
  • Conclusions
    The BFCs tested had similar performance compared to the conventional composite when used in up to 2-mm increments. When the increment was thicker, the BFCs were properly polymerized only up to 3 mm.
Resin composites are the most used direct restorative materials in the dental clinic daily [1]. Among the properties of resin composites, polymerization shrinkage is currently one of the most significant issues, which could lead to failures in the adhesive interface between resin composites and tooth structure [2,3]. In order to reduce the effect of the polymerization shrinkage stress, the incremental technique is used. However, this technique has disadvantages such as increased clinical time, the incorporation of air bubbles and the probabilities of making errors in the procedure [2,4,5]. Also, because a conventional resin composite does not polymerize correctly in thicknesses greater than 2 mm, and greater thickness would increase the contraction stress generated, it is established that the incremental technique is performed in a maximum of 2-mm increments in order to reduce the polymerization stress generated with the least amount of increments as possible [6,7].
Thus, new systems called bulk fill resin composites (BFCs) have currently been introduced to the market, and generated a paradigm shift by establishing their use in up to 4-mm increments [2,3,5]. These BFCs are presented with consistencies equal to conventional resin composites, and although they can be used in any cavity, they are mainly indicated in posterior restorations [4,6,7,8]. Despite this, it should be noted that in some cases a conventional resin composite surface layer is indicated, to achieve a better aesthetic result [9]. The BFCs composition is similar to conventional ones; however, each manufacturer adds some modifications to achieve adequate behavior up to 4 mm as modified monomers, flexible fillers or even photoinitiators to achieve correct polymerization and decrease the generated polymerization stress [4,10,11,12]. On the other hand, a lower amount of filler is reported compared to conventional resin composites, which would allow a better light passage at those depths [11].
BFCs would simplify the clinical steps of conventional resin composites such as the incremental technique, or air trapping between layers since they would be placed in a single increment [6,13]. Due to the paradigm shift, a debate arises as to whether these new generation materials actually manage to polymerize in 4 millimeters, maintaining the physical, chemical and biological characteristics of conventional resin composites [12,14]. Despite that there are several studies that characterize these kinds of resin composites, it is still unclear its behavior at several depths [15,16,17]. Therefore, the purpose of this work was to analyze the physical-chemical behavior of 2 commercial BFCs and compare them with a conventional resin composite. The null hypothesis to be tested was that the physicochemical properties of BFCs will be similar to conventional resin composite when evaluated in 2- or 4-mm thicknesses.
Experimental design
This in vitro study investigated the physicochemical properties of 3 resin composites. The materials tested were: 2 BFCs (Filtek Bulk Fill [FBF], 3M ESPE, St. Paul, MN, USA; and Tetric-N-Ceram Bulk Fill [TBF], Ivoclar-Vivadent, Schaan, Liechtenstein) and one conventional resin composite (Filtek Z250, 3M ESPE). These materials were chosen since they are the first worldwide available and their use is widely spread among clinicians. The materials were manipulated according to the manufacturer's instructions and they were photoactivated using a LED curing unit (1,000 mW/cm2; Radii Cal, SDI, Bayswater, Australia). Flexural properties were evaluated according to International Organization for Standardization (ISO) 4049. Knoop hardness measurements were performed at depth areas 0–1, 1–2, 2–3, and 3–4 mm from the top surface. The translucency parameter (TP) was measured using an optical spectrophotometer. The degree of conversion and polymerization rate were determined at 2- and 4-mm depths.
Flexural strength and elastic modulus
Bar-shaped specimens (2 × 2 × 25 mm; n = 10) were prepared by filling the uncured resin composite material into a stainless-steel mold placed on a glass slide covered by a Mylar strip (DuPont, Wilmington, DE, USA) to avoid oxygen inhibition of polymerization. Samples were irradiated 3 times on both sides using the overlapping technique [18]. Each overlap was light-cured for 20 seconds. After polymerization, specimens were removed from the mold and flashes and irregularities were removed with 600-grit abrasive papers and their dimensions measured with a 0.01 mm accuracy using a digital caliper. The specimens were then stored in distilled water for 24 hours at 37ºC prior to mechanical testing. The mechanical test was performed following ISO 4049 standard, using a universal testing machine (EMIC DL500, EMIC Co., Sao Paulo, Brazil) at a cross-head speed of 1 mm/s until fracture [18]. The flexural strength (σf) and elastic modulus (Ef) were determined using the equations provided by international standards and expressed in MPa and GPa respectively:
σf = 3Pl/2bh2Ef = 3P1l3/4bh3d
where P is the load at the time of fracture (N), l is the distance between the supports (20 mm), b is the width (mm) and h is the height of the specimen (mm), P1 is the maximum load on the linear portion (proportional limit) of the stress-deformation trace, and d is the deflection of the specimen at load P1.
Knoop hardness number
Specimens for hardness determination (n = 5) were created using custom-made stainless-steel mold with a semicircular notch measuring 5 mm in length and 2 mm in diameter as described previously [19]. Briefly, the semicircular notch was then filled with each one of the resin composites. Then, the mold was covered with a Mylar strip and covered by a stainless-steel plate. The resin composite was then light-cured through the surface opening for 20 seconds. After light-polymerizing, the plate and Mylar strip were removed and the mold including the resin composite specimen was placed under a microhardness tester (FM 700, Future-Tech Corp., Kawasaki, Japan). Following, hardness measurements (kgf/mm2) were made on the specimens at defined areas from the top surface (0–1 mm, 1–2 mm, 2–3 mm, and 3–4 mm) with a Knoop indenter using a 25-gram load applied for 10 seconds (Figure 1). On each area, 3 subsequent indentations were done, and the mean value was registered. Hardness loss (%HL) for each depth was calculated in percentage using the following formula: %HLx = (KHNx−KHN0–1) × 100/KHN0–1. Where KHNx is the Knoop hardness number at 1–2, 2–3, or 3–4 mm and KHN0–1 is the Knoop hardness at 0–1 mm.
Figure 1

Illustration for hardness measurements at different depths of the specimen. (A) Upper view of the inferior part of the mold. (B) Lateral view of mold and photoactivation direction. (C) Division of the specimen in 4-mm layers for the hardness test. (D) Indentation performed at the 0–1 mm area.

rde-46-e39-g001.jpg
Translucency parameter
The TP of each resin composite was measured using an optical spectrophotometer (SP60, X-Rite, Grand Rapids, MI, USA). For this, the cylindrical specimens (diameter 7 mm, thickness 1 mm; n = 5) were obtained by filling the uncured material into silicon molds and polymerized for 20 seconds. The CIE L*a*b* color coordinates were measured after storing the specimens in distilled water at 37°C. Color readings were taken over white (L* = 93.07, a* = 1.28, b* = 5.25) and black (L* = 27.94, a* = 0.01, b* = 0.03) backgrounds. The TP for each specimen was calculated using the formula:
TP = [(L*w − L*b)2 + (a*w − a*b)2 + (b*w − b*b)2]1/2
where w and b refer to the color coordinates measured on the white and black backgrounds [20].
Polymerization kinetics
An infrared spectrophotometer equipped with an attenuated total reflection (ATR) cell unit (Prestige-21, Shimadzu, Kyoto, Japan) was used to measure the polymerization rate and the degree of carbon double bonds conversion. A small specimen (up to 100 mg; n = 3) of each material was placed into a cylindrical mold (5-mm diameter, and 2- or 4-mm height) on the ATR unit diamond cell, then a celluloid sheet and a slide glass were placed, standardizing the material thickness. The IR solution spectrophotometer software package (v. 1.60, Shimadzu) was used in the monitoring scan mode in the range of 1,500–1,800 cm−1, a resolution of 4 cm−1 and a mirror speed of 2.8 mm/s. With this configuration, 1 scan was acquired every second during 40 seconds of photoactivation. The experiment was performed 3 times for each of the evaluated groups. In each of the spectra, the absorption band height of the aliphatic uC=C bond was measured at 1,638 cm−1 as well as the absorption band height of the aromatic uC=C bond located at 1,609 cm−1. The degree of C=C conversion of the materials was calculated using the following equation [21]:
Degree of C=C conversion% = 1001 − A1638A1609polymer/A1638A1609monomer
where A1638 is the maximum band height at 1,638 cm−1 and A1609 is the maximum band height at 1,609 cm−1. The degree of double bond conversion vs. polymerization reaction time data was plotted and Hill's 1 3-parameter nonlinear regression was performed for curve fitting. Using these data, the polymerization rate (RP) was calculated as the degree of conversion at time t subtracted from the degree of conversion at time t−1 [22].
Statistical analysis
Statistical analysis was performed using Sigma Plot 14.0 software (Systat Software, Inc., San Jose, CA, USA). Data from flexural strength, elastic modulus, Knoop hardness number, TP, and degree of conversion were analyzed to verify the normal distribution and homogeneity of variance. A 1-way analysis of variance (ANOVA) followed by Tukey's post hoc test was used to compare data from flexural strength, elastic modulus, hardness, and TP. The degree of conversion was analyzed using a 2-way ANOVA (material and depth factors) followed by Tukey's post hoc test. In all cases, the significance level was set at α = 0.05.
Figure 2 shows the results of flexural strength and elastic modulus. For flexural strength, there were no statistically significant differences among the evaluated groups (p = 0.636). When analyzing the elastic modulus, the Z250 and FBF resin composites did not show statistically significant differences between them (p = 0.939), while TBF presented a significantly lower elastic modulus (p < 0.05).
Figure 2

Means and standard deviations for flexural strength (A) and elastic modulus (B). Columns under the same horizontal line indicate no statistical difference (p > 0.05).

rde-46-e39-g002.jpg
The results of the Knoop hardness test in depth can be seen in Figure 3. Each material was analyzed independently. For Z250, no statistically significant differences were detected only for the comparison between areas 0–1 and 1–2 mm (p = 0.184), being that the results of areas 2–3 and 3–4 mm decreased significantly (p < 0.05). For FBF, the results show that the Knoop hardness remained similar up to area 2–3 mm depth (p > 0.05), decreasing significantly at area 3–4 mm (p < 0.05). Regarding the results obtained for TBF, only statistically significant differences were detected for comparisons between areas 0–1 and 3–4 mm (p < 0.01), and between areas 1–2 and 3–4 mm (p = 0.002).
Figure 3

Means and standard deviations for Knoop hardness number (kgf/mm2). For each material, columns under the same horizontal line indicate no statistical difference (p > 0.05). Hardness loss (%HL) for each material is shown within the rectangles (%HL2/%HL3/%HL4).

rde-46-e39-g003.jpg
The %HL analysis shows that for FBF, the hardness from areas 0–1 to 1–2 and from areas 0–1 to 3–4 mm was reduced by 3% and 31% respectively; for TBF, the reduction from area 0–1 to 1–2 mm was 11%, while from area 0–1 to 3–4 mm, the reduction was 35%. Finally, it was observed that the conventional resin composite Z250 reduced its hardness from area 0–1 to 1–2 and from area 0–1 to 3–4 mm by 9.5% and 56.5%, respectively.
For the TP, the Z250 material obtained significantly lower values than BFCs (p < 0.05), as shown in Figure 4. On the other hand, the comparison between both BFCs showed the absence of statistically significant differences (p = 0.735). The degree of conversion and the polymerization rate are shown in Figure 5. The degree of conversion was significantly influenced by depth (p < 0.001), material (p < 0.001) and the interaction of both (p < 0.001). Considering the depth factor, for Z250 and FBF materials, the degree of conversion decreased significantly between 2- and 4-mm depths (p < 0.001). On the other hand, for TBF, no statistically significant differences were detected between 2- and 4-mm depths (p = 0.077). Analyzing the material factor, none of the evaluated resin composites had statistically significant differences at 2-mm depth (p > 0.05), while at 4-mm depth, the Z250 resin composite obtained significantly lower values (p < 0.001). Regarding the polymerization rate, when evaluated at 2-mm depth, both BFC achieved higher polymerization rate max values (Z250: 0.12; FBF: 0.25; TBF: 0.26). While, when evaluated at 4-mm depth, a drastic decrease in Rp is observed for all the materials (Z250: 0.01; FBF: 0.07; TBF: 0.11).
Figure 4

Means and standard deviations for translucency parameter. Columns under the same horizontal line indicate no statistical difference (p > 0.05).

rde-46-e39-g004.jpg
Figure 5

Data-fitted plots of polymerization kinetics of the resin composites evaluated. Degree of C=C conversion as a function of time shows the maximum conversion achieved at 2- and 4-mm depth (A). Polymerization rate (RP) profiles (B) as a function of time for 2- and 4-mm increments.

rde-46-e39-g005.jpg
In this study, the physicochemical properties of 2 BFCs and one conventional resin composite were evaluated. The results showed that the properties evaluated mainly depended on the depth used. When analyzing the behavior of the material, it was observed that hardness and polymerization kinetics values drastically decreased at 4 mm when compared to those obtained at 2 mm. The main findings observed in this study help to demonstrate the influence of the BFCs composition and its relation with the physical and chemical properties. Higher BFCs translucency can be associated with the maintenance of the polymerization kinetic parameters. Also, the lowest DC observed at 4-mm depth, could be associated with a lower Knoop hardness at 4-mm depth, as observed here. Considering this, the null hypothesis tested in this study is rejected.
When analyzing flexural strength, all the resin composites seem to have a statistically similar value. At this point, it is important to highlight that the ISO 4049 standard establishes only the mechanical analysis with 2 mm thick specimens, so this analysis does not directly compare the material behavior when used in different thicknesses, but it was carried out to understand the general mechanical behavior of these materials compared to a conventional resin composite. In the literature, this controversy regarding the current standard to analyze resinous type materials has been discussed [23].
When the elastic modulus is analyzed, FBF seems to be the resin composite with the highest rigidity, with statistically similar values to Z250. This could be related to the fact that both materials had a similar amount of filler content [24]. On the other hand, TBF showed statistically lower values, which can be interpreted as greater material flexibility. This behavior could be explained by several reasons, first, the filler content of this material is lower than the other resin composites evaluated. Also, when the composition of this material was analyzed, it was observed that the manufacturer includes an elastic filler, whose function is to dissipate the stresses caused by polymerization [25]. The addition of this filler could be responsible for the decrease in the elastic modulus, even though it presents a greater amount of filler in its composition compared to Z250 or FBF. On the other hand, the addition of specific monomers, of high molecular weight or greater flexibility could be modifying the obtained values [26]. The results regarding flexural strength and elastic modulus obtained in this study are in agreement with previous findings [27,28].
Regarding the hardness analysis, it could be observed that Z250 conventional resin composite showed higher hardness at the 0–1 mm area than BFCs. These results are in accordance with previous findings, where it was found that conventional resin composites had significantly higher hardness values than several BFCs [29,30]. These results could be related to the presence of aluminum oxide in the Z250 material, also the differences in the organic matrix among the materials, such as the presence of elastic monomers within the BFCs composition, could also have an influence [31,32]. Despite the differences obtained, the hardness in BFCs does not present great variations up to the area of 2–3 mm depth, being that at the area of 3–4 mm a statistically significant decrease was observed in both BFC's (p < 0.05). When analyzing the variation in the decrease in hardness in each millimeter (%HLx) it is possible to see that, up to the area of 2–3 mm deep, the hardness decreases less than 20%, this corresponds to what was reported by Van Ende et al. [33] and establishes that the depth to which the material maintains 80% of the surface hardness is acceptable. Whereas the conventional resin composite meets this parameter of 80% of hardness, only up to 2-mm thickness as expected. This corroborates the inability of conventional resin composites to be used at depths greater than 2 mm. When reaching the area of 3–4 mm depth, the hardness in all materials falls more than 30%, which could suggest a clinically relevant loss of mechanical properties, related to the polymerization quality obtained at that depth.
Flury et al. [23] related hardness and depth of polymerization in BFCs, confirming that the method proposed by ISO4049 for the curing depth analysis in this type of material generates an overestimation of the results. This is important since the properties within the resin composite decrease with increasing depth, resulting in a non-homogeneous material, which can render less predictable outcomes [33]. In this line of reasoning, it was possible to highlight that several modifications to the ISO 4049 standard may be necessary for the BFCs analysis, since, as previously discussed, it does not contemplate such behavior for flexural resistance either.
On the other hand, although hardness is not a parameter established by current ISO regulations, it is possible to see how conventional Z250 resin composite has a higher hardness in the first 2 mm compared to BFCs. This behavior was already described before and it was correlated with the differences in filler composition, size and loading of the BFCs [34]. This could explain why several manufacturers indicate the coating of this type of material with conventional resin composites, since lower hardness values are related to greater wear and loss of the material surface polishing [35]. Despite this, it should be highlighted that a recent systematic review with meta-analysis demonstrated that BFCs show a lower hardness when compared to conventional composites at 2-mm depth, but no significant differences were observed in the survival rate [34].
Regarding the TP, it was possible to determine that both BFCs presented significantly higher values than the conventional resin composite. These results are in agreement with those previously reported by Bucuta et al. [36]. The increase in BFCs translucency can be explained by several factors, among which it is possible to find the use of formulations with a lesser amount of inorganic filler, which is consistent with the found hardness results, as well as the use of fillers that, due to their composition, have a better refractive index matching with the organic matrix, which ends up favoring the light penetration through the material, and therefore, the maintenance of their properties after a certain depth [37,38,39]. This increase in light penetration through the material could be the reason why BFCs had the least decrease in Knoop hardness between the surface (area 0–1 mm) and the bottom (area 3–4 mm) of the specimens. In fact, it has been found that the polymerization depth of photoactivated materials is limited by the attenuation of the emitted energy by the light-emitting apparatus through the material, and that this is inversely proportional to the material translucency [33].
In this study, the degree of conversion and polymerization rate, at depths of 2 and 4 mm, were also evaluated. As expected, the degree of conversion values of the materials measured at a depth of 2 mm were similar. These findings could be confirmed by previous research by Garoushi et al. [40], where the degree of conversion was significantly influenced by thickness. The degree of conversion is a property that depends on intrinsic and extrinsic factors, among the intrinsic the photoinitiator system, the type of monomer system and the amount and type of inorganic filler are found. On the other hand, among the extrinsic factors, it is possible to find those variables related to the light emission source that triggers the polymerization process [41]. Considering this, it is probable that, at a depth of 2 mm, all the materials evaluated in this study have the same capacity to transmit the light emitted by the photopolymerizing apparatus, resulting in an adequate material polymerization [36].
When analyzing the polymerization rate at 2 mm, the BFCs had a considerable increase in Rp compared to conventional resin composite. This increase is likely to have occurred due to the presence of special, stress-relieving monomers in the BFCs formulation, as well as the use of alternative initiators such as Ivocerin (Ivoclar-Vivadent) [42,43]. The presence of stress-relief monomers within the BFCs composition has been proved to increase the propagation of the polymerization reaction during the auto acceleration stage [44]. On the other hand, previous studies have shown that Ivocerin acts as a polymerization booster in BFCs, allowing efficient polymerization at the depth of 4 mm [45,46].
On the other hand, when analyzing the polymerization kinetics parameters at a depth of 4 mm, it is possible to observe that the conventional resin composite had an unsatisfactory performance. This effect can be explained by the impossibility that the light emitted by the photopolymerizing device has to completely cross the 4 mm depth in which the material was evaluated. It has been previously determined that as the thickness of the resin composite material increases, there is a decrease in light transmission, resulting in a decrease in the degree of conversion [47,48]. In fact, this is the explanation why conventional resin composite manufacturers recommend that increments do not exceed 2 mm. In the case of BFCs, the values obtained at 4 mm are due, in part, to an increase in the material translucency [36]. On the other hand, for the TBF material, it is possible that the use of Ivocerin as a photoinitiator has also had some influence since it has proven to be more effective than camphorquinone for radical methacrylates polymerization [49].
The BFCs tested had similar performance compared to the conventional composite when used in up to 2-mm increments. When the increment was thicker, the bulk fill composites were properly polymerized only up to 3 mm. It seems that the use of increments thicker than 3 mm should be carried out with caution in the clinical setting.
The authors want to thank 3M ESPE (Uruguay) and Ivoclar-Vivadent (Uruguay) for materials donation. This study was financed in part by the Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES), Brazil (Finance Code 001).

Conflict of Interest: No potential conflict of interest relevant to this article was reported.

Author Contributions:

  • Conceptualization: Grazioli G, Cuevas-Suárez CE, Francia A.

  • Formal analysis: Grazioli G, Cuevas-Suárez CE.

  • Investigation: Grazioli G, Cuevas-Suárez CE, Nakanishi L.

  • Project administration: Grazioli G.

  • Resources: Moraes RR.

  • Supervision: Moraes RR.

  • Validation: Moraes RR.

  • Writing - original draft: Grazioli G, Cuevas-Suárez CE.

  • Writing - review & editing: Nakanishi L, Francia A, Moraes RR.

  • 1. Garcia D, Yaman P, Dennison J, Neiva G. Polymerization shrinkage and depth of cure of bulk fill flowable composite resins. Oper Dent 2014;39:441-448. ArticlePubMedPDF
  • 2. Orłowski M, Tarczydło B, Chałas R. Evaluation of marginal integrity of four bulk-fill dental composite materials: in vitro study. Sci World J 2015;2015:701262.
  • 3. Ferracane JL. Resin composite--state of the art. Dent Mater 2011;27:29-38. PubMed
  • 4. Benetti AR, Havndrup-Pedersen C, Honoré D, Pedersen MK, Pallesen U. Bulk-fill resin composites: polymerization contraction, depth of cure, and gap formation. Oper Dent 2015;40:190-200. ArticlePubMedPDF
  • 5. Krämer N, Lohbauer U, García-Godoy F, Frankenberger R. Light curing of resin-based composites in the LED era. Am J Dent 2008;21:135-142. PubMed
  • 6. Corral Núñez C, Vildósola-Grez P, Bersezio-Miranda C, Alves-Dos Campos E, Fernández Godoy E. Revisión del estado actual de resinas compuestas bulk-fill. Rev Fac Odontol Univ Antioq 2015;27:177-196.
  • 7. Ferracane JL, Hilton TJ, Stansbury JW, Watts DC, Silikas N, Ilie N, Heintze S, Cadenaro M, Hickel R. Academy of dental materials guidance-resin composites: part II-technique sensitivity (handling, polymerization, dimensional changes). Dent Mater 2017;33:1171-1191. PubMed
  • 8. Nascimento AS, de Lima EA, Durao MA, Sousa YC, Correia TC, Braz R. Marginal microleakage in Bulk Fill resins. Rev Odontol UNESP 2016;45:327-331.Article
  • 9. Al-Harbi F, Kaisarly D, Bader D, El Gezawi M. Marginal integrity of bulk versus incremental fill class II composite restorations. Oper Dent 2016;41:146-156. ArticlePubMedPDF
  • 10. El-Damanhoury H, Platt J. Polymerization shrinkage stress kinetics and related properties of bulk-fill resin composites. Oper Dent 2014;39:374-382. ArticlePubMedPDF
  • 11. Rengo C, Spagnuolo G, Ametrano G, Goracci C, Nappo A, Rengo S, Ferrari M. Marginal leakage of bulk fill composites in class II restorations: a microCT and digital microscope analysis. Int J Adhes Adhes 2015;60:123-129.Article
  • 12. Ilie N, Bucuta S, Draenert M. Bulk-fill resin-based composites: an in vitro assessment of their mechanical performance. Oper Dent 2013;38:618-625. ArticlePubMedPDF
  • 13. Swift EJ Jr. Critical appraisal: bulk-fill composites, part I. J Esthet Restor Dent 2015;27:176-179. ArticlePubMedPDF
  • 14. Khamverdi Z, Fazelian N, Aghaei M. Comparative evaluation of microleakage in class V composite resin restorations using two bulk filled resin composites and one conventional composite (grandio). Ann Dent Spec 2018;6:17-22.
  • 15. Ilie N, Stark K. Curing behaviour of high-viscosity bulk-fill composites. J Dent 2014;42:977-985. PubMed
  • 16. Czasch P, Ilie N. In vitro comparison of mechanical properties and degree of cure of bulk fill composites. Clin Oral Investig 2013;17:227-235.ArticlePubMedPDF
  • 17. Li X, Pongprueksa P, Van Meerbeek B, De Munck J. Curing profile of bulk-fill resin-based composites. J Dent 2015;43:664-672. ArticlePubMed
  • 18. International Organization for Standardization. ISO 4049:2009 Dentistry — Polymer based restorative materials. Geneva: International Organization for Standardization; 2009.
  • 19. de Araújo CS, Schein MT, Zanchi CH, Rodrigues SA Jr, Demarco FF. Composite resin microhardness: the influence of light curing method, composite shade, and depth of cure. J Contemp Dent Pract 2008;9:43-50. ArticlePubMed
  • 20. Sharma G, Wu W, Dalal EN. The CIEDE2000 color-difference formula: implementation notes, supplementary test data, and mathematical observations. Color Res Appl 2005;30:21-30.
  • 21. Herrera-González AM, Caldera-Villalobos M, Pérez-Mondragón AA, Cuevas-Suárez CE, González-López JA. Analysis of double bond conversion of photopolymerizable monomers by FTIR-ATR spectroscopy. J Chem Educ 2019;96:1786-1789.Article
  • 22. Moraes RR, Faria-e-Silva AL, Ogliari FA, Correr-Sobrinho L, Demarco FF, Piva E. Impact of immediate and delayed light activation on self-polymerization of dual-cured dental resin luting agents. Acta Biomater 2009;5:2095-2100. ArticlePubMed
  • 23. Flury S, Hayoz S, Peutzfeldt A, Hüsler J, Lussi A. Depth of cure of resin composites: Is the ISO 4049 method suitable for bulk fill materials? Dent Mater 2012;28:521-528. ArticlePubMed
  • 24. Masouras K, Silikas N, Watts DC. Correlation of filler content and elastic properties of resin-composites. Dent Mater 2008;24:932-939. PubMed
  • 25. Son SA, Park JK, Seo DG, Ko CC, Kwon YH. How light attenuation and filler content affect the microhardness and polymerization shrinkage and translucency of bulk-fill composites? Clin Oral Investig 2017;21:559-565.ArticlePubMedPDF
  • 26. Marovic D, Tauböck TT, Attin T, Panduric V, Tarle Z. Monomer conversion and shrinkage force kinetics of low-viscosity bulk-fill resin composites. Acta Odontol Scand 2015;73:474-480. ArticlePubMed
  • 27. Leprince JG, Palin WM, Vanacker J, Sabbagh J, Devaux J, Leloup G. Physico-mechanical characteristics of commercially available bulk-fill composites. J Dent 2014;42:993-1000. ArticlePubMed
  • 28. Cuevas-Suárez CE, Pimentel-García B, Rivera-Gonzaga A, Álvarez-Gayosso C, Ancona-Meza AL, Grazioli G, Zamarripa-Calderón E. Examining the effect of radiant exposure on commercial photopolimerizable dental resin composites. Dent J (Basel) 2018;6:55.PubMedPMC
  • 29. Abed YA, Sabry HA, Alrobeigy NA. Degree of conversion and surface hardness of bulk-fill composite versus incremental-fill composite. Tanta Dent J 2015;12:71-80.Article
  • 30. Camassari JR, Correr-Sobrinho L, Correr AB, Puppin-Rontani J, Stipp RN, Puppin-Rontani RM, Paula AB. Physical-mechanical properties of bulk fill composites submitted to biodegradation by Streptococcus mutans . Braz Dent J 2020;31:431-439. ArticlePubMed
  • 31. Vojdani M, Bagheri R, Khaledi AA. Effects of aluminum oxide addition on the flexural strength, surface hardness, and roughness of heat-polymerized acrylic resin. J Dent Sci 2012;7:238-244.Article
  • 32. Tchorz JP, Doll R, Wolkewitz M, Hellwig E, Hannig C. Microhardness of composite materials with different organic phases in deep class II cavities: an in vitro study. Oper Dent 2011;36:502-511. PubMed
  • 33. Van Ende A, De Munck J, Lise DP, Van Meerbeek B. Bulk-fill composites: a review of the current literature. J Adhes Dent 2017;19:95-109. PubMed
  • 34. Cidreira Boaro LC, Pereira Lopes D, de Souza AS, Lie Nakano E, Ayala Perez MD, Pfeifer CS, Gonçalves F. Clinical performance and chemical-physical properties of bulk fill composites resin -a systematic review and meta-analysis. Dent Mater 2019;35:e249-e264. ArticlePubMed
  • 35. Tomaszewska IM, Kearns JO, Ilie N, Fleming GJ. Bulk fill restoratives: to cap or not to cap--That is the question? J Dent 2015;43:309-316. ArticlePubMed
  • 36. Bucuta S, Ilie N. Light transmittance and micro-mechanical properties of bulk fill vs. conventional resin based composites. Clin Oral Investig 2014;18:1991-2000.ArticlePubMedPDF
  • 37. Lee YK. Influence of filler on the difference between the transmitted and reflected colors of experimental resin composites. Dent Mater 2008;24:1243-1247. ArticlePubMed
  • 38. Shortall AC, Palin WM, Burtscher P. Refractive index mismatch and monomer reactivity influence composite curing depth. J Dent Res 2008;87:84-88. ArticlePubMedPDF
  • 39. Fujita K, Nishiyama N, Nemoto K, Okada T, Ikemi T. Effect of base monomer's refractive index on curing depth and polymerization conversion of photo-cured resin composites. Dent Mater J 2005;24:403-408. ArticlePubMed
  • 40. Garoushi S, Vallittu P, Shinya A, Lassila L. Influence of increment thickness on light transmission, degree of conversion and micro hardness of bulk fill composites. Odontology 2016;104:291-297. PubMed
  • 41. Leprince JG, Palin WM, Hadis MA, Devaux J, Leloup G. Progress in dimethacrylate-based dental composite technology and curing efficiency. Dent Mater 2013;29:139-156. ArticlePubMed
  • 42. Fronza BM, Rueggeberg FA, Braga RR, Mogilevych B, Soares LE, Martin AA, Ambrosano G, Giannini M. Monomer conversion, microhardness, internal marginal adaptation, and shrinkage stress of bulk-fill resin composites. Dent Mater 2015;31:1542-1551. ArticlePubMed
  • 43. Radebner J, Eibel A, Leypold M, Gorsche C, Schuh L, Fischer R, Torvisco A, Neshchadin D, Geier R, Moszner N, Liska R, Gescheidt G, Haas M, Stueger H. Tetraacylgermanes: highly efficient photoinitiators for visible-light-induced free-radical polymerization. Angew Chem Int Ed Engl 2017;56:3103-3107. ArticlePubMedPDF
  • 44. Al-Ahdal K, Ilie N, Silikas N, Watts DC. Polymerization kinetics and impact of post polymerization on the degree of conversion of bulk-fill resin-composite at clinically relevant depth. Dent Mater 2015;31:1207-1213. PubMed
  • 45. Al-Mansour K, Al-Sada A, Al-Sinan H. Curing depth of bulk-fill composites-an in-vitro study. Pak Oral Dent J 2015;35:270-274.
  • 46. Yap AU, Pandya M, Toh WS. Depth of cure of contemporary bulk-fill resin-based composites. Dent Mater J 2016;35:503-510. ArticlePubMed
  • 47. Price RB, Murphy DG, Dérand T. Light energy transmission through cured resin composite and human dentin. Quintessence Int 2000;31:659-667. PubMed
  • 48. Price RB, Dérand T, Loney RW, Andreou P. Effect of light source and specimen thickness on the surface hardness of resin composite. Am J Dent 2002;15:47-53. PubMed
  • 49. Moszner N, Fischer UK, Ganster B, Liska R, Rheinberger V. Benzoyl germanium derivatives as novel visible light photoinitiators for dental materials. Dent Mater 2008;24:901-907. ArticlePubMed

Tables & Figures

REFERENCES

    Citations

    Citations to this article as recorded by  

      • ePub LinkePub Link
      • Cite
        CITE
        export Copy Download
        Close
        Download Citation
        Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

        Format:
        • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
        • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
        Include:
        • Citation for the content below
        Physicochemical characterization of two bulk fill composites at different depths
        Restor Dent Endod. 2021;46(3):e39  Published online July 5, 2021
        Close
      • XML DownloadXML Download
      Figure
      • 0
      • 1
      • 2
      • 3
      • 4
      Physicochemical characterization of two bulk fill composites at different depths
      Image Image Image Image Image
      Figure 1 Illustration for hardness measurements at different depths of the specimen. (A) Upper view of the inferior part of the mold. (B) Lateral view of mold and photoactivation direction. (C) Division of the specimen in 4-mm layers for the hardness test. (D) Indentation performed at the 0–1 mm area.
      Figure 2 Means and standard deviations for flexural strength (A) and elastic modulus (B). Columns under the same horizontal line indicate no statistical difference (p > 0.05).
      Figure 3 Means and standard deviations for Knoop hardness number (kgf/mm2). For each material, columns under the same horizontal line indicate no statistical difference (p > 0.05). Hardness loss (%HL) for each material is shown within the rectangles (%HL2/%HL3/%HL4).
      Figure 4 Means and standard deviations for translucency parameter. Columns under the same horizontal line indicate no statistical difference (p > 0.05).
      Figure 5 Data-fitted plots of polymerization kinetics of the resin composites evaluated. Degree of C=C conversion as a function of time shows the maximum conversion achieved at 2- and 4-mm depth (A). Polymerization rate (RP) profiles (B) as a function of time for 2- and 4-mm increments.
      Physicochemical characterization of two bulk fill composites at different depths

      Restor Dent Endod : Restorative Dentistry & Endodontics
      Close layer
      TOP