Skip Navigation
Skip to contents

Restor Dent Endod : Restorative Dentistry & Endodontics

OPEN ACCESS

Search

Page Path
HOME > Search
6 "WaveOne Gold"
Filter
Filter
Article category
Keywords
Publication year
Authors
Research Articles
Effect of number of uses and sterilization on the instrumented area and resistance of reciprocating instruments
Victor de Ornelas Peraça, Samantha Rodrigues Xavier, Fabio de Almeida Gomes, Luciane Geanini Pena dos Santos, Erick Miranda Souza, Fernanda Geraldo Pappen
Restor Dent Endod 2021;46(2):e28.   Published online April 29, 2021
DOI: https://doi.org/10.5395/rde.2021.46.e28
AbstractAbstract PDFPubReaderePub
Objectives

This study evaluated the effect of repeated uses and autoclaving in the instrumented area, fracture resistance, and time of instrumentation of thermally treated nickel-titanium reciprocating systems.

Materials and Methods

Two hundred simulated canals were instrumented using Reciproc Blue and WaveOne Gold. Each file was used up to 10 times or until fracture. The instrumented area was measured in pre- and post-operative images, using ImageJ software. Kaplan-Meier survival analysis evaluated the number of uses of instruments before fracture. Instrumented area and time of instrumentation were analyzed by Mann-Whitney U test and Kruskal-Wallis. Correlations among the number of uses and instrumented area were measured. The level of statistical significance was set at p < 0.05.

Results

Reciproc Blue presented a higher estimated number of uses in comparison with WaveOne Gold (p = 0.026), but autoclaving did not affect the resistance to fracture of instruments (p > 0.05). The instrumented area was different among the evaluated groups (p = 0.039), and the instrumented area along the uses of both tested instruments was reduced. With the time of instrumentation, there was also a significant difference among the evaluated groups; the groups without sterilization cycles were faster, in comparison to those submitted to autoclaving (p = 0.010).

Conclusions

Reciproc Blue was more resistant than WaveOne Gold, suffering later fracture. Additionally, the sterilization cycles did not influence the estimated number of uses of thermally treated reciprocating instruments, but the instrumented area of root canals was reduced along with the repeated uses of both instruments.

Citations

Citations to this article as recorded by  
  • The influence of autoclave sterilization on the cyclic fatigue of M-wire rotary endodontic instruments
    Nenad Stosic, Jelena Popovic, Antonije Stankovic, Aleksandar Mitic, Marija Nikolic, Kosta Todorovic
    Vojnosanitetski pregled.2024; 81(10): 642.     CrossRef
  • 225 View
  • 11 Download
  • 1 Web of Science
  • 1 Crossref
Close layer
Comparison of vibration characteristics of file systems for root canal shaping according to file length
Seong-Jun Park, Se-Hee Park, Kyung-Mo Cho, Hyo-Jin Ji, Eun-Hye Lee, Jin-Woo Kim
Restor Dent Endod 2020;45(4):e51.   Published online October 14, 2020
DOI: https://doi.org/10.5395/rde.2020.45.e51
AbstractAbstract PDFPubReaderePub
Objectives

No studies have yet assessed vibration characteristics according to endodontic file length. Accordingly, the objective of the present study was to examine the vibration characteristics according to nickel-titanium file length and to compare these characteristics between different file systems.

Materials and Methods

A total of 45 root canal models were divided into 3 experimental groups (n = 15 each) based on the file system used (ProTaper Gold [PTG], ProTaper Next, or WaveOne Gold [WOG]). Each experimental group was further divided into 3 subgroups according to file length (21, 25, or 31 mm). An electric motor (X-SMART PLUS) was used in the experiment. For each file system, vibrations generated when using a size 25 file were measured and used to calculate the average vibration acceleration. The differences in vibrations were analyzed using 1-way analysis of variance and the Scheffé post hoc test with a confidence interval of 95%.

Results

In the PTG file system, significantly lower vibration acceleration was observed when using a 21-mm file than when using a 31-mm file. In the WOG file system, significantly stronger vibration acceleration was observed when using a 31-mm file than when using 21- or 25-mm files. Regardless of the file length, the WOG group exhibited significantly stronger vibration acceleration than the other 2 experimental groups.

Conclusions

In clinical practice, choosing a file with the shortest length possible could help reduce vibrations. Additionally, consideration should be given to vibrations that could be generated when using WOG files with reciprocating motion.

Citations

Citations to this article as recorded by  
  • Comparison vibration characteristics of several wireless endodontic handpieces
    Bo-Kyung Lee, Yoon Lee, Se-Hee Park, Kyung-Mo Cho, Jin-Woo Kim
    Journal of Dental Rehabilitation and Applied Science.2022; 38(2): 81.     CrossRef
  • 194 View
  • 2 Download
  • 1 Crossref
Close layer
Cyclic fatigue resistance of the WaveOne Gold Glider, ProGlider, and the One G glide path instruments in double-curvature canals
Damla Kırıcı, Alper Kuştarcı
Restor Dent Endod 2019;44(4):e36.   Published online September 9, 2019
DOI: https://doi.org/10.5395/rde.2019.44.e36
AbstractAbstract PDFPubReaderePub
Objectives

The aim of this study was to compare the cyclic fatigue resistance of the WaveOne Gold Glider, ProGlider and One G glide path instruments in artificial double-curvature canals.

Materials and Methods

This study included 15 WaveOne Gold Glider (size 15/0.08), 15 ProGlider (size 16/0.08), and 15 One G (size 16/0.06) nickel titanium files. The files were used in accordance with the manufacturer's instructions until they were broken in artificial double-curvature canals made of stainless steel. The time to fracture was recorded via a digital stopwatch and the number of rotations until fracture was also calculated. The data were statistically analyzed via the Kruskal-Wallis test.

Results

The highest average number of rotations until fracture of the files was found for the WaveOne Gold Glider, followed by ProGlider and One G in order. Statistically significant differences were present between all groups of files (p < 0.05).

Conclusions

In our study, the resistance of the WaveOne Gold Glider nickel-titanium (Ni-Ti) file to cyclic fatigue in S-shaped curved canals was found to be higher than that of the ProGlider and One G Ni-Ti files.

Citations

Citations to this article as recorded by  
  • Glide Path in Endodontics: A Literature Review of Current Knowledge
    Vlad Mircea Lup, Giulia Malvicini, Carlo Gaeta, Simone Grandini, Gabriela Ciavoi
    Dentistry Journal.2024; 12(8): 257.     CrossRef
  • In Vitro Evaluation of the Dynamic Cyclic Fatigue Resistance of a New TruNatomy Glider File after Different Cycles of Use
    Lorena Ferreira Rego, Juliana Delatorre Bronzato, Alana Pinto Carôso Souza, Adriana de-Jesus-Soares, Marcos Frozoni
    Journal of Endodontics.2024; 50(5): 619.     CrossRef
  • Comparative Evaluation of the Cyclic Fatigue Resistance of WaveOne Gold in Reciprocation, ProGlider in Rotary Motion, and Manual Files in a Reciprocating Handpiece Within Simulated Curved Canals: An In Vitro Study
    Shivangi M Pujara, Hardik B Shah, Leena H Jobanputra
    Cureus.2024;[Epub]     CrossRef
  • Comparative analysis of torsional and cyclic fatigue resistance of ProGlider, WaveOne Gold Glider, and TruNatomy Glider in simulated curved canal
    Pedro de Souza Dias, Augusto Shoji Kato, Carlos Eduardo da Silveira Bueno, Rodrigo Ricci Vivan, Marco Antonio Hungaro Duarte, Pedro Henrique Souza Calefi, Rina Andréa Pelegrine
    Restorative Dentistry & Endodontics.2023;[Epub]     CrossRef
  • Negotiability of mesiobuccal canals in maxillary first molars using different path file systems
    Maryam Gharechahi, Mandana Khajehpour, Ali Hamedi, Maryam Peighoun
    Dental Research Journal.2023;[Epub]     CrossRef
  • Cyclic Fatigue Resistance of Glide Path Rotary Files: A Systematic Review of in Vitro Studies
    Israa Ashkar, José Luis Sanz, Leopoldo Forner
    Materials.2022; 15(19): 6662.     CrossRef
  • Evaluation of design, mechanical properties, and torque/force generation of heat-treated NiTi glide path instruments
    Soram Oh, Ji-Yeon Seo, Ji-Eun Lee, Hyun-Jung Kim, Ji-Hyun Jang, Seok Woo Chang
    BMC Oral Health.2022;[Epub]     CrossRef
  • Body temperature fatigue behaviour of reciprocating and rotary glide path instruments in sodium hypochlorite solutions alone or combined with etidronate
    Dario Perez‐Villalba, José C. Macorra, Juan J. Perez‐Higueras, Ove A. Peters, Ana Arias
    Australian Endodontic Journal.2021; 47(3): 450.     CrossRef
  • 224 View
  • 3 Download
  • 8 Crossref
Close layer
Comparison of the shaping ability of novel thermally treated reciprocating instruments
Cangül Keskin, Murat Demiral, Evren Sarıyılmaz
Restor Dent Endod 2018;43(2):e15.   Published online March 3, 2018
DOI: https://doi.org/10.5395/rde.2018.43.e15
AbstractAbstract PDFPubReaderePub
Objectives

The present study aimed to evaluate the shaping ability of 2 thermally treated nickel-titanium reciprocating systems in simulated curved canals.

Materials and Methods

Forty simulated canals were prepared to apical size 25 using Reciproc Blue R25 (VDW) and WaveOne Gold Primary (Dentsply Sirona) instruments. Standard pre- and post-preparation images were taken and superimposed. The removal of resin material was measured at 5 standard points: the canal orifice, halfway between the canal orifice and the beginning of the curve, the beginning of the curve, the apex of the curve, and the end-point of the simulated canal. The data were analysed using the independent sample t-test with a 5% significance threshold.

Results

The canals in which Reciproc Blue R25 was used showed a significantly greater widening than those in which WaveOne Gold was used at 4 of the 5 measurement points (p < 0.05). The Reciproc Blue R25 instrument removed significantly more resin from the inner aspect of the curve at 2 of the 5 points and similar amounts at the remaining 3 points. At the 2 apical points, there was no significant difference between the Reciproc Blue R25 and WaveOne Gold Primary instruments.

Conclusion

Both instruments respected the original canal anatomy; however, WaveOne Gold resulted in a more conservative shape with less transportation.

Citations

Citations to this article as recorded by  
  • Shaping Ability of the Root Canal System Using Reciproc and Reciproc Blue in Preparation of Artificial Canals
    Hawazin Majdi, Khalid Merdad, Tariq Abuhaimed, Lujain Mirdad, Omar Alkhattab, Abdulaziz Bakhsh
    Pesquisa Brasileira em Odontopediatria e Clínica Integrada.2025;[Epub]     CrossRef
  • Comparison of four different file systems in terms of transportation in S-shaped canals and apically extruded debris
    Mustafa Alrahhal, Fatma Tunç
    Journal of Oral Science.2024; 66(4): 226.     CrossRef
  • Assessment of Debris Extrusion in Curved Canals: An In Vitro Analysis of Various Single‐File Endodontic Instrumentation Systems
    Muhammad Zubair Ahmad, Boonlert Kukiattrakoon
    International Journal of Dentistry.2024;[Epub]     CrossRef
  • Shaping ability of rotary and reciprocating single-file systems in combination with and without different glide path techniques in simulated curved canals
    Lu Shi, Yunfei Yang, Jie Wan, Wen Xie, Ruiming Yang, Ying Yao
    Journal of Dental Sciences.2022; 17(4): 1520.     CrossRef
  • An Investigation of the Accuracy and Reproducibility of 3D Printed Transparent Endodontic Blocks
    Martin Smutný, Martin Kopeček, Aleš Bezrouk
    Acta Medica (Hradec Kralove, Czech Republic).2022; 65(2): 59.     CrossRef
  • Shaping Ability of Reciprocating Single-file Systems in Simulated Canals: Reciproc versus Reciproc Blue
    İrem ÇETİNKAYA, Mukadder İnci BAŞER KOLCU
    SDÜ Tıp Fakültesi Dergisi.2021; 28(1): 145.     CrossRef
  • Combination of a new ultrasonic tip with rotary systems for the preparation of flattened root canals
    Karina Ines Medina Carita Tavares, Jáder Camilo Pinto, Airton Oliveira Santos-Junior, Fernanda Ferrari Esteves Torres, Juliane Maria Guerreiro-Tanomaru, Mario Tanomaru-Filho
    Restorative Dentistry & Endodontics.2021;[Epub]     CrossRef
  • Apical extrusion of debris with different rotary and reciprocating single-file endodontic instrumentation systems: a systematic review and meta-analysis protocol
    Muhammad Zubair Ahmad, Durre Sadaf, Marcy McCall MacBain, Ahmed Nabil Mohamed
    BMJ Open.2020; 10(9): e038502.     CrossRef
  • Micro-computed tomographic assessment of the shaping ability of the One Curve, One Shape, and ProTaper Next nickel-titanium rotary systems
    Pelin Tufenkci, Kaan Orhan, Berkan Celikten, Burak Bilecenoglu, Gurkan Gur, Semra Sevimay
    Restorative Dentistry & Endodontics.2020;[Epub]     CrossRef
  • Changes in Geometry and Transportation of Root Canals with Severe Curvature Prepared by Different Heat-treated Nickel-titanium Instruments: A Micro–computed Tomographic Study
    Daniel José Filizola de Oliveira, Graziela Bianchi Leoni, Rafael da Silva Goulart, Manoel Damião de Sousa-Neto, Yara Teresinha Correa Silva Sousa, Ricardo Gariba Silva
    Journal of Endodontics.2019; 45(6): 768.     CrossRef
  • Several factors can affect the root canal transportation of MB2 canals in extracted maxillary first molars
    R. R. Vivan, M. P. Alcalde, E. J de Camargo, V. A. S. Marques, M. V. R. Só, J. A. Duque, M. A. H. Duarte
    International Endodontic Journal.2019; 52(4): 551.     CrossRef
  • Effect of larger apical size on the quality of preparation in curved canals using reciprocating instruments with different heat thermal treatments
    J. A. Duque, R. R. Vivan, M. A. H. Duarte, M. P. Alcalde, V. M. Cruz, M. M. B. Borges, C. M. Bramante
    International Endodontic Journal.2019; 52(11): 1652.     CrossRef
  • 225 View
  • 1 Download
  • 12 Crossref
Close layer
The effect of root canal preparation on the surface roughness of WaveOne and WaveOne Gold files: atomic force microscopy study
Taha Özyürek, Koray Yılmaz, Gülşah Uslu, Gianluca Plotino
Restor Dent Endod 2018;43(1):e10.   Published online February 2, 2018
DOI: https://doi.org/10.5395/rde.2018.43.e10
AbstractAbstract PDFPubReaderePub
Objectives

To examine the surface topography of intact WaveOne (WO; Dentsply Sirona Endodontics) and WaveOne Gold (WOG; Dentsply Sirona Endodontics) nickel-titanium rotary files and to evaluate the presence of alterations to the surface topography after root canal preparations of severely curved root canals in molar teeth.

Materials and Methods

Forty-eight severely curved canals of extracted molar teeth were divided into 2 groups (n = 24/each group). In group 1, the canals were prepared using WO and in group 2, the canals were prepared using WOG files. After the preparation of 3 root canals, instruments were subjected to atomic force microscopy analysis. Average roughness and root mean square values were chosen to investigate the surface features of endodontic files. The data was analyzed using one-way analysis of variance and post hoc Tamhane's tests at 5% significant level.

Results

The surface roughness values of WO and WOG files significantly changed after use in root canals (p < 0.05). The used WOG files exhibited higher surface roughness change when compared with the used WO files (p < 0.05).

Conclusions

Using WO and WOG Primary files in 3 root canals affected the surface topography of the files. After being used in root canals, the WOG files showed a higher level of surface porosity value than the WO files.

Citations

Citations to this article as recorded by  
  • Comparative Analysis of Surface Roughness and Plastic Deformation of Reciprocating Instruments after Clinical Use
    Ángel Herrera, Magdalena Azabal, Jesús R. Jimenez-Octavio, Juan C. del Real-Romero, Sara López de Armentia, Juan M. Asensio-Gil, Ana Arias
    Materials.2024; 17(16): 3978.     CrossRef
  • Comparative Evaluation of Surface Roughness of Different Rotary Nickel-Titanium (NiTi) Files After Autoclaving: An Atomic Force Microscopic Study
    Angela Alex, Ranjith Kumar Sivarajan, Vijay Venkatesh
    Cureus.2024;[Epub]     CrossRef
  • Impact of endodontic irrigants on surface roughness of various nickel-titanium rotary endodontic instruments
    Tamer M. Hamdy, Yasmine Mohsen Alkabani, Amira Galal Ismail, Manar M. Galal
    BMC Oral Health.2023;[Epub]     CrossRef
  • Metallurgical Tests in Endodontics: A Narrative Review
    Alessio Zanza, Marco Seracchiani, Rodolfo Reda, Gabriele Miccoli, Luca Testarelli, Dario Di Nardo
    Bioengineering.2022; 9(1): 30.     CrossRef
  • Cyclic Fatigue Resistance and Surface Roughness of Rotary NiTi Instruments after Simulated Clinical Use in Curved Root Canals – An Atomic Force Microscopy Study
    Raksha Bhat, Arjun Kini, Preethesh Shetty, Payalben Kansara, Bapanaiah Penugonda
    Pesquisa Brasileira em Odontopediatria e Clínica Integrada.2022;[Epub]     CrossRef
  • In Vitro Study of Irrigation solution of Chitosan Nanoparticles to Inhibit the Adhesion and Biofilm Formation of Enterococcus faecalis in the Root Canal
    Imelda Darmawi, Trimurni Abidin, Harry Agusnar, Basri A. Gani
    Research Journal of Pharmacy and Technology.2022; : 2691.     CrossRef
  • Alteration in surface roughness of reciprocating endodontic instruments
    Khoa Van Pham
    F1000Research.2021; 10: 875.     CrossRef
  • Surface profile of different heat-treated nickel-titanium files before and after root canal preparation
    Iandara de Lima Scardini, Denise Maria Zezell, Juliana Lisboa Couto Marques, Laila Gonzales Freire, Marcelo dos Santos
    Brazilian Dental Journal.2021; 32(6): 8.     CrossRef
  • Impact of Endodontic Instrumentation on Surface Roughness of Various Nickel-Titanium Rotary Files
    Muhammad Sohail Zafar
    European Journal of Dentistry.2021; 15(02): 273.     CrossRef
  • A new method for assessment of nickel-titanium endodontic instrument surface roughness using field emission scanning electronic microscope
    Khoa Van Pham, Canh Quang Vo
    BMC Oral Health.2020;[Epub]     CrossRef
  • Surface Alterations Induced on Endodontic Instruments by Sterilization Processes, Analyzed with Atomic Force Microscopy: A Systematic Review
    Mario Dioguardi, Vito Crincoli, Luigi Laino, Mario Alovisi, Enrica Laneve, Diego Sovereto, Bruna Raddato, Khrystyna Zhurakivska, Filiberto Mastrangelo, Domenico Ciavarella, Lucio Lo Russo, Lorenzo Lo Muzio
    Applied Sciences.2019; 9(22): 4948.     CrossRef
  • Atomic force microscopy and energy dispersive X‐ray spectrophotometry analysis of reciprocating and continuous rotary nickel‐titanium instruments following root canal retreatment
    Bulem Üreyen Kaya, Cevat Emre Erik, Gülsen Kiraz
    Microscopy Research and Technique.2019; 82(7): 1157.     CrossRef
  • Influence of heat treatment on torsional resistance and surface roughness of nickel‐titanium instruments
    E. J. N. L. Silva, J. F. N. Giraldes, C. O. de Lima, V. T. L. Vieira, C. N. Elias, H. S. Antunes
    International Endodontic Journal.2019; 52(11): 1645.     CrossRef
  • 237 View
  • 4 Download
  • 13 Crossref
Close layer
Cyclic fatigue life of Tango-Endo, WaveOne GOLD, and Reciproc NiTi instruments
Koray Yılmaz, Taha Özyürek
Restor Dent Endod 2017;42(2):134-139.   Published online April 11, 2017
DOI: https://doi.org/10.5395/rde.2017.42.2.134
AbstractAbstract PDFPubReaderePub
Objectives

To compare the fatigue life of Tango-Endo, WaveOne GOLD, and Reciproc NiTi instruments under static model via artificial canals with different angles of curvature.

Materials and Methods

Reciproc R25, WaveOne GOLD Primary, and Tango-Endo instruments were included in this study (n = 20). All the instruments were rotated in artificial canals which were made of stainless steel with an inner diameter of 1.5 mm, 45°, 60°, and 90° angles of curvatures and a radius of curvature of 5 mm until fracture occurred, and the time to fracture was recorded in seconds using a digital chronometer. The data were analyzed using Kruskal-Wallis and post-hoc Dunn tests were used for the statistical analysis of data in SPSS 21.0 software.

Results

Tango-Endo files were found to have significantly higher values than WaveOne GOLD and Reciproc files in terms of fatigue life (p < 0.05). However, there was no statistically significant difference between fatigue life of Reciproc and WaveOne GOLD files (p > 0.05). It was determined that increasing the angle of curvature of the stainless canals caused significant decreases in fatigue life of all of three files (p < 0.05).

Conclusions

Within the limitations of the present study, the cyclic fatigue life of Tango-Endo in canals having different angles of curvature was statistically higher than Reciproc and WaveOne GOLD.

Citations

Citations to this article as recorded by  
  • Apically extruded debris of different file systems used with various kinematic movements during retreatment: An in vitro study
    Tuğba Koşar, Davut Çelik, Tamer Taşdemir
    Australian Endodontic Journal.2023; 49(S1): 33.     CrossRef
  • Nickel-titanium files in endodontics: Development, improvement and modifications of nickel-titanium alloy
    Slavoljub Zivkovic, Milica Jovanovic-Medojevic, Jelena Neskovic, Marijana Popovic-Bajic
    Vojnosanitetski pregled.2023; 80(3): 262.     CrossRef
  • FATIGUE FAILURE OF NICKEL-TITANIUM INSTRUMENTS IN ENDODONTICS AND ITS INFLUENCING FACTORS
    A Jusku, T Dodeková, J Staněk, B Özel, P Jirásek, V Polanská, Ľ Harvan
    Česká stomatologie a praktické zubní lékařství.2022; 122(2): 51.     CrossRef
  • Reciproc Endodontic File Surface Defects After Single Use
    Mohammed Howait
    Journal of International Society of Preventive and Community Dentistry.2021; 11(1): 98.     CrossRef
  • A comparative evaluation of cyclic fatigue resistance of Reciproc Blue, WaveOne Gold and 2Shape nickel–titanium rotary files in different artificial canals
    Ankita Grace Lall, Suparna Ganguly Saha, Vijay Alageshan, Parmeet Banga
    Endodontology.2021; 33(1): 1.     CrossRef
  • Cutting efficiency of heat‐treated nickel–titanium single‐file systems at different incidence angles
    Eugenio Pedullà, Pietro La Paglia, Giusy Rita Maria La Rosa, Anna Maria Gueli, Stefania Pasquale, David E. Jaramillo, Leopoldo Forner, Fabio Lo Savio, Guido La Rosa, Ernesto Rapisarda
    Australian Endodontic Journal.2021; 47(1): 20.     CrossRef
  • Influence of the type of reciprocating motion on the cyclic fatigue resistance of reciprocating files in a dynamic model
    Álvaro Zubizarreta-Macho, Alberto Albaladejo Martínez, Carlos Falcão Costa, Norberto Quispe-López, Ruben Agustín-Panadero, Jesús Mena-Álvarez
    BMC Oral Health.2021;[Epub]     CrossRef
  • Cutting efficiency of conventional and heat‐treated nickel–titanium rotary or reciprocating glide path instruments
    E. Pedullà, G. Leanza, G. R. M. La Rosa, A. M. Gueli, S. Pasquale, G. Plotino, E. Rapisarda
    International Endodontic Journal.2020; 53(3): 376.     CrossRef
  • Influence of static and dynamic cyclic fatigue tests on the lifespan of four reciprocating systems at different temperatures
    A. Keleş, A. Eymirli, O. Uyanık, E. Nagas
    International Endodontic Journal.2019; 52(6): 880.     CrossRef
  • Comparison of Cyclic Fatigue Resistance of 5 Heat-treated Nickel-titanium Reciprocating Systems in Canals with Single and Double Curvatures
    Mohammad I. Al-Obaida, Khalid Merdad, Mohammed S. Alanazi, Hesham Altwaijry, Mohammad AlFaraj, Ali A. Alkhamis, Ebtissam M. Al-Madi
    Journal of Endodontics.2019; 45(10): 1237.     CrossRef
  • Assessment of mechanical properties of WaveOne Gold Primary reciprocating instruments
    Tong FANGLI, Keiichiro MAKI, Shunsuke KIMURA, Miki NISHIJO, Daisuke TOKITA, Arata EBIHARA, Takashi OKIJI
    Dental Materials Journal.2019; 38(3): 490.     CrossRef
  • Comparison between Single-file Rotary Systems: Part 2—The Effect of Length of the Instrument Subjected to Cyclic Loading on Cyclic Fatigue Resistance
    Adham A. Azim, Mohamed Tarrosh, Katharina A. Azim, Lucila Piasecki
    Journal of Endodontics.2018; 44(12): 1837.     CrossRef
  • Comparison of cyclic fatigue resistance of XP-endo Shaper, HyFlex CM, FlexMaster and Race instruments
    Mehmet Adiguzel, Ipek Isken, Ismail Ilker Pamukcu
    Journal of Dental Research, Dental Clinics, Dental Prospects.2018; 12(3): 208.     CrossRef
  • 210 View
  • 3 Download
  • 13 Crossref
Close layer

Restor Dent Endod : Restorative Dentistry & Endodontics
Close layer
TOP