Relationship between laboratory bond strengths and clinical performance of dentin adhesives
Skip Navigation
Skip to contents

Restor Dent Endod : Restorative Dentistry & Endodontics

OPEN ACCESS

Articles

Page Path
HOME > Restor Dent Endod > Volume 41(4); 2016 > Article
Readers' Forum Relationship between laboratory bond strengths and clinical performance of dentin adhesives
Young-Kyung Kim
Restorative Dentistry & Endodontics 2016;41(4):341-342.
DOI: https://doi.org/10.5395/rde.2016.41.4.341
Published online: October 10, 2016

Kyungpook National University, Korea.

©Copyrights 2016. The Korean Academy of Conservative Dentistry.

This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

  • 17 Views
  • 0 Download
prev
Can we assume that dentin adhesives with high bond strengths guarantee a better clinical performance?
Bond strength tests are the most common method to evaluate the quality of the adhesive bond simply because they are simple to perform. We can see endless publications on bond strengths of dentin adhesives. We should note that most of the bond strength tests in the literature use an extremely simplified design: a flat, polished, and homogeneous bonding area. Such a design of bonding area may be substantially different from prepared cavities to be bonded in dental practice.
The papers on dental bonding report the values in megapascals (MPa) because the 'bond strength' is defined as the load needed to break a bond divided by the cross-sectional area of the bonding interface. However, this unit 'MPa' may be unfamiliar to many dental clinicians. Let's assume that a dentin adhesive produced a dentin bond strength of 20 MPa. Then, 20 MPa = 20 × 106 Pa = 20 N/10-6 m2 = approximately 2 kgf/mm2. Although the shear bond strength test is simpler than the tensile bond strength test, the former has a limitation of measuring the cohesive strength of the adherend (or sometimes substrate) rather than the true bond strength of the bonding interface. Therefore, the shear bond strength test does not simulate the clinical mode of failure, which is mainly adhesive failure. When the main failure mode is cohesive in a bond strength test, the bond strength values have no definite clinical meaning.
In scientific papers on bonding, we judge that a bond strength value is significantly different from another by the p value. According to a 'Michelin Guide' scale, we can find various signfincances: signfincant (p < 0.05), highly signfincant (p < 0.01), and extremlely signfincant (p < 0.001). However, the term statistically 'significant' has just a simple meaning. When the p value is less than a preset threshold value alpha (commonly 0.05), it doesn't matter whether the p value is very close to alpha or far away. If adhesive A (16 MPa) showed an extremely significantly (p < 0.0001) higher bond strength value than adhesive B (14 MPa), does this finding indicate that adhesive A is extremely superior to adhesive B in a clinical bonding performance? Not at all! Do not forget that the p value is greatly dependent on the sample size.
Although in vitro studies attempt to mimic clinical situations, clinical trials are considered the ultimate way to provide evidences on the clinical effectiveness of restorative materials. We can infer if an adhesive is truly reliable for routine clinical work from in vivo studies in which all possible aging factors act simultaneously. Therefore, when we read a paper regarding dentin bonding, we should try to think what the bond strength says in the context of dentin bonding rather than simply read the value itself.
Readers' forum is edited by Professor Kyung-Mo Cho (Gangneung-Wonju National University).
  • 1. Van Meerbeek B, Peumans M, Poitevin A, Mine A, Van Ende A, Neves A, De Munck J. Relationship between bond-strength tests and clinical outcomes. Dent Mater 2010;26:e100-e121. ArticlePubMed
  • 2. Christensen GJ. Bonding to dentin and enamel where does it stand in 2005? J Am Dent Assoc 2005;136:1299-1302. PubMed
  • 3. Bouillaguet S, Troesch S, Wataha JC, Krejci I, Meyer JM, Pashley DH. Microtensile bond strength between adhesive cements and root canal dentin. Dent Mater 2003;19:199-205. ArticlePubMed
  • 4. Della Bona A, van Noort R. Shear vs. tensile bond strength of resin composite bonded to ceramic. J Dent Res 1995;74:1591-1596. PubMed
  • 5. Motulsky H. Intuitive biostatistics. 1st ed. New York, NY: Oxford University Press; 1995. Chapter 12.
  • 6. Roulet JF. Statistics: nuisance - tool - necessity? J Adhes Dent 2013;15:203. PubMed
  • 7. Sudsangiam S, van Noort R. Do dentin bond strength tests serve a useful purpose? J Adhes Dent 1999;1:57-67. PubMed
  • 8. Heintze SD. Systematic reviews: I. The correlation between laboratory tests on marginal quality and bond strength. II. The correlation between marginal quality and clinical outcome. J Adhes Dent 2007;9(Supplement 1):77-106. PubMed

Tables & Figures

REFERENCES

    Citations

    Citations to this article as recorded by  

      • ePub LinkePub Link
      • Cite
        CITE
        export Copy Download
        Close
        Download Citation
        Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

        Format:
        • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
        • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
        Include:
        • Citation for the content below
        Relationship between laboratory bond strengths and clinical performance of dentin adhesives
        Restor Dent Endod. 2016;41(4):341-342.   Published online October 10, 2016
        Close
      • XML DownloadXML Download
      Relationship between laboratory bond strengths and clinical performance of dentin adhesives
      Relationship between laboratory bond strengths and clinical performance of dentin adhesives

      Restor Dent Endod : Restorative Dentistry & Endodontics
      Close layer
      TOP