Skip Navigation
Skip to contents

Restor Dent Endod : Restorative Dentistry & Endodontics

OPEN ACCESS

Search

Page Path
HOME > Search
2 "Shadepilot"
Filter
Filter
Article category
Keywords
Publication year
Authors
Basic Research
Clinical assessment of whitening efficacy and safety of in-office tooth whitening system containing 15% hydrogen peroxide with or without light activation
Young-Suk Noh, Young-Jee Rho, Yeon-Jee Yoo, Hyang-Ok Lee, Sang-Min Lim, Hyun-Jeong Kweon, Yeun Kim, Seong-Yeon Park, Hee-Young Yoon, Jung-Hyun Lee, Chan-Hee Lee, So-Ram Oh, Kee-Yeon Kum
J Korean Acad Conserv Dent 2011;36(4):306-312.   Published online July 31, 2011
DOI: https://doi.org/10.5395/JKACD.2011.36.4.306
AbstractAbstract PDFPubReaderePub
Objectives

This clinical study evaluated the effect of light activation on the whitening efficacy and safety of in-office bleaching system containing 15% hydrogen peroxide gel.

Materials and Methods

Thirty-three volunteers were randomly treated with (n = 17, experimental group) or without light activation (n = 16, control group), using Zoom2 white gel (15% H2O2, Discus Dental) for a total treatment time of 45 min. Visual and instrumental color measurements were obtained using Vitapan Classical shade guide and Shadepilot (DeguDent) at screening test, after bleaching, and 1 month and 3 month after bleaching. Data were analyzed using t-test, repeated measure ANOVA, and chi-squared test.

Results

Zoom2 white gel produced significant shade changes in both experimental and control group when pre-treatment shade was compared with that after bleaching. However, shade difference between two groups was not statistically significant (p > 0.05). Tooth shade relapse was not detected at 3 months after bleaching. The incidence of transient tooth sensitivity was 39.4%, with being no differences between two groups.

Conclusions

The application of light activation with Zoom2 white gel system neither achieved additional whitening effects nor showed more detrimental influences.

Citations

Citations to this article as recorded by  
  • Effect of preference drinks on tooth color reduction after tooth bleaching: A 12-momth follow-up study
    Hyo Jin Goo, Min Jeong Cho, Yun Sook Jung, Ji Hye Kim, Fan Dong, Keun Bae Song
    Journal of Korean Academy of Oral Health.2016; 40(1): 55.     CrossRef
  • Development of a Piezoelectric Ultrasonic Tooth-whitening Apparatus
    Young-Jin Lee, Jong-Hoo Paik, Jeong-Bae Lee, Seung-Jae Choi
    Transactions on Electrical and Electronic Materials.2013; 14(5): 268.     CrossRef
  • 182 View
  • 2 Download
  • 2 Crossref
Close layer
Original Article
Clinical study of shade improvement and safety of polymer-based pen type BlancTic Forte whitening agent containing 8.3% Carbamide peroxide
Jin-Kyung Lee, Sun-Hong Min, Sung-Tae Hong, So-Ram Oh, Shin-Hye Chung, Young-Hye Hwang, Sung-Yeop You, Kwang-Shik Bae, Seung-Ho Baek, Woo-Cheol Lee, Won-Jun Son, Kee-Yeon Kum
J Korean Acad Conserv Dent 2009;34(2):154-161.   Published online March 31, 2009
DOI: https://doi.org/10.5395/JKACD.2009.34.2.154
AbstractAbstract PDFPubReaderePub

This clinical study evaluated the whitening effect and safety of polymer based-pen type BlancTis Forte (NIBEC) containing 8.3% carbamide peroxide. Twenty volunteers used the BlancTis Forte whitening agent for 2 hours twice a day for 4 weeks. As a control, Whitening Effect Pen (LG) containing 3% hydrogen peroxide was used by 20 volunteers using the same protocol. The change in shade (ΔE*, color difference) was measured using Shadepilot™ (DeguDent) before, during, and after bleaching (2 weeks, 4 weeks, and post-bleaching 4 weeks). A clinical examination for any side effects (tooth hypersensitivity or soft tissue complications) was also performed at each check-up. The following results were obtained.

1. Both the experimental and control groups displayed a noticeable change in shade (ΔE) of over 2. No significant differences were found between the two groups (p > 0.05), implying that the two agents have a similar whitening effect.

2. The whitening effect was mainly due to changes in a and b values rather than in L value (brightness). The experimental group showed a significantly higher change in b value, thus yellow shade, than the control (p < 0.05).

3. None of the participants complained of tooth hypersensitivity or soft tissue complications, confirming the safety of both whitening agents.

Citations

Citations to this article as recorded by  
  • Surface Damage and Bleaching Effect according to the Application Type of Home Tooth Bleaching Applicants
    Na-Yeoun Tak, Do-Seon Lim, Hee-Jung Lim, Im-Hee Jung
    Journal of Dental Hygiene Science.2020; 20(4): 252.     CrossRef
  • Efficacy of a self - applied paint - on whitening gel combined with wrap
    Soo-Yeon Kim, Jae-Hyun Ahn, Ji-Young Kim, Jin-Woo Kim, Se-Hee Park, Kyung-Mo Cho
    Journal of Dental Rehabilitation and Applied Science.2018; 34(3): 175.     CrossRef
  • 165 View
  • 1 Download
  • 2 Crossref
Close layer

Restor Dent Endod : Restorative Dentistry & Endodontics
Close layer
TOP