Influence of inorganic composition and filler particle morphology on the mechanical properties of self-adhesive resin cements
Marina Rodrigues Santi, Rodrigo Barros Esteves Lins, Beatriz Ometto Sahadi, Giovanna Corrêa Denucci, Gabriela Soffner, Luís Roberto Marcondes Martins
Restor Dent Endod 2022;47(3):e32.   Published online July 14, 2022
DOI: https://doi.org/10.5395/rde.2022.47.e32
AbstractAbstract PDFPubReaderePub
Objectives

This study aimed to evaluate the influence of inorganic composition and filler particle morphology on the mechanical properties of different self-adhesive resin cements (SARCs).

Materials and Methods

Three SARCs including RelyX Unicem-2 (RUN), Maxcem Elite (MAX), and Calibra Universal (CAL) were tested. Rectangular bar-shaped specimens were prepared for flexural strength (FS) and flexural modulus (FM) and determined by a 3-point bending test. The Knoop microhardness (KHN) and top/bottom microhardness ratio (%KHN) were conducted on the top and bottom faces of disc-shaped samples. Sorption (Wsp) and solubility (Wsl) were evaluated after 24 hours of water immersion. Filler morphology was analyzed by scanning electron microscopy and X-ray energy dispersive spectroscopy (EDS). FS, FM, %KHN, Wsp, Wsl, and EDS results were submitted to 1-way analysis of variance and Tukey’s post-hoc test, and KHN also to paired t-test (α = 0.05).

Results

SARC-CAL presented the highest FS value, and SARC-RUN presented the highest FM. SARC-MAX and RUN showed the lowest Wsp and Wsl values. KHN values decreased from top to bottom and the SARCs did not differ statistically. Also, all resin cements presented carbon, aluminum, and silica in their composition. SARC-MAX and RUN showed irregular and splintered particles while CAL presented small and regular size particles.

Conclusions

A higher mechanical strength can be achieved by a reduced spread in grit size and the filler morphology can influence the KHN, as well as photoinitiators in the composition. Wsp and Wsl can be correlated with ions diffusion of inorganic particles.

  • 28 View
  • 2 Download
  • 4 Web of Science
Close layer
Effects of radiant exposure and wavelength spectrum of light-curing units on chemical and physical properties of resin cements
Adriano Fonseca Lima, Stephanie Ellen Ferreira Formaggio, Lígia França Aires Zambelli, Alan Rodrigo Muniz Palialol, Giselle Maria Marchi, Cintia Helena Coury Saraceni, Marcelo Tavares de Oliveira
Restor Dent Endod 2016;41(4):271-277.   Published online September 26, 2016
DOI: https://doi.org/10.5395/rde.2016.41.4.271
AbstractAbstract PDFPubReaderePub
Objectives

In this study, we evaluated the influence of different radiant exposures provided by single-peak and polywave light-curing units (LCUs) on the degree of conversion (DC) and the mechanical properties of resin cements.

Materials and Methods

Six experimental groups were established for each cement (RelyX ARC, 3M ESPE; LuxaCore Dual, Ivoclar Vivadent; Variolink, DMG), according to the different radiant exposures (5, 10, and 20 J/cm2) and two LCUs (single-peak and polywave). The specimens were made (7 mm in length × 2 mm in width × 1 mm in height) using silicone molds. After 24 hours of preparation, DC measurement was performed using Fourier transform infrared spectrometry. The same specimens were used for the evaluation of mechanical properties (flexural strength, FS; elastic modulus, E) by a three-point bending test. Data were assessed for normality, after which two-way analysis of variance (ANOVA) and post hoc Tukey's test were performed.

Results

No properties of the Variolink cement were influenced by any of the considered experimental conditions. In the case of the RelyX ARC cement, DC was higher when polywave LCU was used; FS and E were not influenced by the conditions evaluated. The LuxaCore cement showed greater sensitivity to the different protocols.

Conclusions

On the basis of these results, both the spectrum of light emitted and the radiant exposure used could affect the properties of resin cements. However, the influence was material-dependent.

  • 17 View
  • 0 Download
Close layer
Comparison of mechanical properties of a new fiber reinforced composite and bulk filling composites
Hazem Abouelleil, Nelly Pradelle, Cyril Villat, Nina Attik, Pierre Colon, Brigitte Grosgogeat
Restor Dent Endod 2015;40(4):262-270.   Published online September 2, 2015
DOI: https://doi.org/10.5395/rde.2015.40.4.262
AbstractAbstract PDFPubReaderePub
Objectives

The aim of this study was to evaluate the mechanical and physical properties of a newly developed fiber reinforced dental composite.

Materials and Methods

Fiber reinforced composite EverX Posterior (EXP, GC EUROPE), and other commercially available bulk fill composites, including Filtek Bulk Fill (FB, 3M ESPE), SonicFill (SF, Kerr Corp.), SureFil (SDR, Dentsply), Venus Bulk Fill (VB, HerausKultzer), Tetric evoceram bulk fill (TECB, Ivoclar Vivadent), and Xtra Base (XB, Voco) were characterized. Composite samples light-cured with a LED device were evaluated in terms of flexural strength, flexural modulus (ISO 4049, n = 6), fracture toughness (n = 6), and Vickers hardness (0, 2, and 4 mm in depth at 24 hr, n = 5). The EXP samples and the fracture surface were observed under a scanning electron microscopy. Data were statistically analyzed using one-way ANOVA and unpaired t-test.

Results

EXP, FB, and VB had significantly higher fracture toughness value compared to all the other bulk composite types. SF, EXP, and XB were not statistically different, and had significantly higher flexural strength values compared to other tested composite materials. EXP had the highest flexural modulus, VB had the lowest values. Vickers hardness values revealed SF, EXP, TECB, and XB were not statistically different, and had significantly higher values compared to other tested composite materials. SEM observations show well dispersed fibers working as a reinforcing phase.

Conclusions

The addition of fibers to methacrylate-based matrix results in composites with either comparable or superior mechanical properties compared to the other bulk fill materials tested.

  • 29 View
  • 1 Download
Close layer
Original Article
The effect of environment on the physical properties of core materials
Yoo-Sook Hwang, Kyoung-Kyu Choi, Sang-Jin Park
J Korean Acad Conserv Dent 2005;30(2):86-94.   Published online March 31, 2005
DOI: https://doi.org/10.5395/JKACD.2005.30.2.086
AbstractAbstract PDFPubReaderePub

The purpose of this study was to measure the flexural strength and hardness of four core materials in 4 different medias and to evaluate the relationship between the physical properties.

For the flexural strength, the specimens were prepared from each of the following materials: Bisfil Core, Core Max, Fuji IX GP, Miracle Mix and randomly divided into four groups and stored at 37 degree C in the following medias: distilled water for 24 hours (DW/1), distilled water for 30 days (DW/30). 2% NaF for 30 days (NF/30), 0.02N lactic acid for 30 days (LA/30). After storage, the specimens were subjected to flexural strength testing and calculated to flexural modulus.

For hardness testing, specimens were prepared from four materials and storaged in the uniform way. After storage, the specimens were subjected to Vicker's hardness testing.

1. The flexural strength of Core Max were the highest, and the flexural strength of Miracle Mix were the lowest.

2. The hardness of Bisfil Core were the highest.

3. The hardness of Core Max were the highest.

4. The hardness of Miracle Mix were the lowest.

5. 2% NaF and 0.02N lactic acid negatively affected the flexural strength and hardness of four core materials.