IN VITRO EVALUATION OF CLEANING EFFICACY OF VARIOUS IRRIGATION METHODS IN MANDIBULAR MOLARS
-
So-Young Lee, Won-Jun Son, WooCheol Lee, Kee-Yeon Kum, Kwang-Shik Bae, Seung-Ho Baek
-
J Korean Acad Conserv Dent 2009;34(3):215-222. Published online January 14, 2009
-
DOI: https://doi.org/10.5395/JKACD.2009.34.3.215
-
-
Abstract
PDFPubReaderePub
- Abstract
The aim of this in vitro study was to evaluate the cleaning efficacy of various irrigation methods in the mandibular mesial roots. The forty five mesial root canals were shaped by Profile .06 instruments to apical size #30 and irrigated with 5 ml of 3.5% NaOCl. The teeth were divided into 3 groups and irrigated finally for 1 minute; Group 1: syringe irrigation, Group 2: ultrasonic irrigation, Group 3: RinsEndo irrigation.
After histological processing, the cross sections of apical 1, 3, and 5 mm level were examined with an optical microscope. The cleanliness values of canals and isthmuses were calculated and analyzed by Mann-Whitney U test.
There were no significant differences in both canal and isthmus cleanliness between syringe irrigation and ultrasonic irrigation except 5 mm level of isthmus.
RinsEndo irrigation had significantly higher canal cleanliness values than syringe irrigation at 1 mm and 3 mm levels (p < 0.05). Also, RinsEndo irrigation had significantly higher isthmus cleanliness values than syringe irrigation at all levels evaluated (p < 0.05).
There were no statistical differences in both canal and isthmus cleanliness between ultrasonic irrigation and RinsEndo irrigation except 3 mm level of canal. From this study, RinsEndo irrigation can be useful as an additional irrigation procedure.
-
A clinical evaluation of a bleaching strip containing 2.9% hydrogen peroxide
-
Eun-Sook Park, So-Rae Seong, Seong-Tae Hong, Ji-Eun Kim, So-Young Lee, Soo-Youn Hwang, Shin-Jae Lee, Bo-Hyoung Jin, Ho-Hyun Son, Byeong-Hoon Cho
-
J Korean Acad Conserv Dent 2006;31(4):269-281. Published online July 31, 2006
-
DOI: https://doi.org/10.5395/JKACD.2006.31.4.269
-
-
Abstract
PDFPubReaderePub
This study evaluated the effectiveness and safety of an experimental bleaching strip (Medison dental whitening strip, Samsung medical Co., Anyang, Korea) containing 2.9% hydrogen peroxide. Twenty-three volunteers used the bleaching strips for one and a half hour daily for 2 weeks. As control group, the same strips in which hydrogen peroxide was not included were used by 24 volunteers with the same protocol. The shade change (ΔE*, color difference) of twelve anterior teeth was measured using Shade Vision (X-Rite Inc., S.W. Grandville, MI, USA), Chroma Meter (Minolta Co., Ltd. Osaka, Japan) and Vitapan classical shade guide (Vita Zahnfabrik, Germany). The shade change of overall teeth in the experimental group was significantly greater than that in the control group (p < 0.05) and was easily perceivable. The change resulted from the increase of lightness (CIE L* value) and the decrease of redness (CIE a* value) and yellowness (CIE b* value). The shade change of individual tooth was greatest in canine, and smallest in central incisor. The safety of the bleaching strip was also confirmed.
|