-
Esthetic rehabilitation of single anterior edentulous space using fiber-reinforced composite
-
Hyeon Kim, Min-Ju Song, Su-Jung Shin, Yoon Lee, Jeong-Won Park
-
Restor Dent Endod 2014;39(3):220-225. Published online May 19, 2014
-
DOI: https://doi.org/10.5395/rde.2014.39.3.220
-
-
Abstract
PDFPubReaderePub
A fiber-reinforced composite (FRC) fixed prosthesis is an innovative alternative to a traditional metal restoration, as it is a conservative treatment method. This case report demonstrates a detailed procedure for restoring a missing anterior tooth with an FRC. A 44-year-old woman visited our department with an avulsed tooth that had fallen out on the previous day and was completely dry. This tooth was replanted, but it failed after one year. A semi-direct technique was used to fabricate a FRC fixed partial prosthesis for its replacement. The FRC framework and the pontic were fabricated using a duplicated cast model and nanofilled composite resin. Later on, interproximal contact, tooth shape, and shade were adjusted at chairside. This technique not only enables the clinician to replace a missing tooth immediately after extraction for minimizing esthetic problems, but it also decreases both tooth reduction and cost.
-
Considerations during crown reattachment procedure over the pulpal exposure: case report
-
Bona Kim, Yoon Lee, Min-Ju Song, Su-Jung Shin, Jeong-Won Park
-
Restor Dent Endod 2012;37(4):240-244. Published online November 21, 2012
-
DOI: https://doi.org/10.5395/rde.2012.37.4.240
-
-
Abstract
PDFPubReaderePub
Crown reattachment is the most conservative treatment which can be used to restore fractured tooth, presumably with sufficient strength, while maintaining original contour, incisal translucency, and reducing chair time and cost. However, in case of crown fracture with pin-point pulp exposure, we should cautiously minimize the irritation to the pulp and consider pre-treatment pulpal status, choice of pulp capping materials, choice of bonding system and treatment sequence during crown reattachment procedures. This case reports the considerations while crown reattachment with direct pulp capping using calcium hydroxide (Dycal, Dentsply Caulk).
-
Prevention of tooth discoloration associated with triple antibiotics
-
Bona Kim, Min-Ju Song, Su-Jung Shin, Jeong-Won Park
-
Restor Dent Endod 2012;37(2):119-122. Published online May 18, 2012
-
DOI: https://doi.org/10.5395/rde.2012.37.2.119
-
-
Abstract
PDFPubReaderePub
Regenerative endodontics has a potential to heal a partially necrotic pulp, which can be beneficial for the continued root development and strengthening of immature teeth. For this purpose, triple antibiotic mixture of ciprofloxacin, metronidazole, and minocycline was recommended as intracanal medicament in an attempt to disinfect the root canal system for revascularization of a tooth with a necrotic pulp. However, discoloration of the tooth was reported after applying this. This case shows the idea for preventing the tooth discoloration using a delivery syringe (SW-O-01, Shinwoo dental) to avoid the contact between the clinical crown and the antibiotics.
-
The evaluation of surface roughness and polishing time between polishing systems
-
Ye-Mi Kim, Su-Jung Shin, Min-Ju Song, Jeong-Won Park
-
J Korean Acad Conserv Dent 2011;36(2):119-124. Published online March 31, 2011
-
DOI: https://doi.org/10.5395/JKACD.2011.36.2.119
-
-
Abstract
PDFPubReaderePub
-
Objectives
The purpose of this experiment was to evaluate four different polishing systems of their polishability and polishing time.
Materials and Methods
4 mm diameter and 2 mm thickness Teflon mold was made. Z-250 (3M ESPE) hybrid composite resin was slightly overfilled and pressed with slide glass and cured with Optilux 501 for 40 sec each side. Then the surface roughness (glass pressed: control group) was measured with profilometer. One surface of the specimen was roughened by #320 grit sand paper and polished with one of the following polishing systems; Sof-Lex (3M ESPE), Jiffy (Ultradent), Enhance (Dentsply/Caulk), or Pogo (Dentsply/Caulk). The surface roughness and the total polishing time were measured. The results were analyzed with one-way ANOVA and Duncan's multiple range test.
Results
The surface roughness was lowest in Pogo, and highest in Sof-Lex. Polishing times were shortest with Pogo, and followed by the Sof-Lex, Enhance and Jiffy.
Conclusions
One-step polishing system (Pogo) is very effective to get the smooth surface in a short time, therefore it can be recommended for final polishing system of the restoration.
-
Comparison of apical transportation and change of working length in K3, NRT AND PROFILE rotary instruments using transparent resin block
-
Min-Jung Yoon, Min-Ju Song, Su-Jung Shin, Euiseong Kim
-
J Korean Acad Conserv Dent 2011;36(1):59-65. Published online January 31, 2011
-
DOI: https://doi.org/10.5395/JKACD.2011.36.1.59
-
-
Abstract
PDFPubReaderePub
-
Objectives
The purpose of this study is to compare the apical transportation and working length change in curved root canals created in resin blocks, using 3 geometrically different types of Ni-Ti files, K3, NRT, and Profile.
Materials and Methods
The curvature of 30 resin blocks was measured by Schneider technique and each groups of Ni-Ti files were allocated with 10 resin blocks at random. The canals were shaped with Ni-Ti files by Crown-down technique. It was analyzed by Double radiograph superimposition method (Backman CA 1992), and for the accuracy and consistency, specially designed jig, digital X-ray, and CAD/CAM software for measurement of apical transportation were used. The amount of apical transportation was measured at 0, 1, 3, 5 mm from 'apical foramen - 0.5 mm' area, and the alteration of the working length before and after canal shaping was also measured. For statistics, Kruskal-Wallis One Way Analysis was used.
Results
There was no significant difference between the groups in the amount of working length change and apical transportation at 0, 1, and 3 mm area (p = 0.027), however, the amount of apical transportation at 5 mm area showed significant difference between K3 and Profile system (p = 0.924).
Conclusions
As a result of this study, the 3 geometrically different Ni-Ti files showed no significant difference in apical transportation and working length change and maintained the original root canal shape.
|