Skip Navigation
Skip to contents

Restor Dent Endod : Restorative Dentistry & Endodontics

OPEN ACCESS

Author index

Page Path
HOME > Browse articles > Author index
Search
Gianluca Plotino 4 Articles
Comparison of shaping ability of the Reciproc Blue and One Curve with or without glide path in simulated S-shaped root canals
Vincenzo Biasillo, Raffaella Castagnola, Mauro Colangeli, Claudia Panzetta, Irene Minciacchi, Gianluca Plotino, Simone Staffoli, Luca Marigo, Nicola Maria Grande
Restor Dent Endod 2022;47(1):e3.   Published online December 28, 2022
DOI: https://doi.org/10.5395/rde.2022.47.e3
AbstractAbstract PDFPubReaderePub
Objectives

This study aimed to assess the impact of a glide-path on the shaping ability of 2 single-file instruments and to compare the centering ability, maintenance of original canal curvatures and area of instrumentation in simulated S-shaped root canals.

Materials and Methods

Forty simulated S-shaped root canals were used and were prepared with One Curve (group OC), One G and OC (group GOC), Reciproc Blue (group RB) and R-Pilot and RB (group PRB) and scanned before and after instrumentation. The images were analyzed using AutoCAD. After superimposing the samples, 4 levels (D1, D2, D3, and D4) and 2 angles (Δ1 and Δ2) were established to evaluate the centering ability and modification of the canal curvatures. Then, the area of instrumentation (ΔA) was measured. The data were analyzed using 2-way analysis of variance and Tukey's test for multiple comparisons (p < 0.05).

Results

Regarding the centering ability in the apical part (D3, D4), the use of the glide-path yielded better results than the single-file groups. Among the groups at D4, OC showed the worst results (p < 0.05). The OC system removed less material (ΔA) than the RB system, and for Δ1, OC yielded a worse result than RB (p < 0.05).

Conclusions

The glide-path improved the centering ability in the apical part of the simulated S-shaped canals. The RB system showed a better centering ability in the apical part and major respect of the canal curvatures compared with OC system.

  • 29 View
  • 4 Download
  • 4 Web of Science
Close layer
The fate of overfilling in root canal treatments with long-term follow-up: a case series
Vito Antonio Malagnino, Alfio Pappalardo, Gianluca Plotino, Teocrito Carlesi
Restor Dent Endod 2021;46(2):e27.   Published online April 29, 2021
DOI: https://doi.org/10.5395/rde.2021.46.e27
AbstractAbstract PDFPubReaderePub

This study describes 6 cases of endodontic overfilling with successful clinical outcomes during long-term (up to 35 years) radiographic follow-up. Successful endodontic treatment depends on proper shaping, disinfection, and obturation of root canals. Filling materials should completely fill the root canal space without exceeding the anatomical apex. Overfilling may occur when the filling material extrudes into the periapical tissues beyond the apex. The present case series describes 6 root canal treatments in which overfilling of root canal sealer and gutta-percha accidentally occurred. Patients’ teeth were periodically checked with periapical radiographs in order to evaluate the outcomes during long-term follow-up. All cases showed healing and progressive resorption of the extruded materials in the periapex. The present cases showed that if a 3-dimensional seal was present at the apical level, overfilling did not negatively affect the long-term outcomes of root canal treatment.

  • 28 View
  • 1 Download
  • 7 Web of Science
Close layer
Comparison of the cyclic fatigue resistance of VDW.ROTATE, TruNatomy, 2Shape, and HyFlex CM nickel-titanium rotary files at body temperature
Mustafa Gündoğar, Gülşah Uslu, Taha Özyürek, Gianluca Plotino
Restor Dent Endod 2020;45(3):e37.   Published online June 22, 2020
DOI: https://doi.org/10.5395/rde.2020.45.e37
AbstractAbstract PDFPubReaderePub
Objectives

This study aims to compare the cyclic fatigue resistance of VDW.ROTATE, TruNatomy, 2Shape, and HyFlex CM nickel-titanium (NiTi) rotary files at body temperature.

Materials and Methods

In total, 80 VDW.ROTATE (25/0.04), TruNatomy (26/0.04), 2Shape (25/0.04), and HyFlex CM (25/0.04) NiTi rotary files (n = 20 in each group) were subjected to static cyclic fatigue testing at body temperature (37°C) in stainless-steel artificial canals prepared according to the size and taper of the instruments until fracture occurred. The number of cycles to fracture (NCF) was calculated, and the lengths of the fractured fragments were measured. The data were statistically analyzed using a 1-way analysis of variance and post hoc Tamhane tests at the 5% significance level (p < 0.05).

Results

There were significant differences in the cyclic fatigue resistance among the groups (p < 0.05), with the highest to lowest NCF values of the files as follows: VDW.ROTATE, HyFlex CM, 2Shape, and TruNatomy. There was no significant difference in the lengths of the fractured fragments among the groups. The scanning electron microscope images of the files revealed typical characteristics of fracture due to cyclic fatigue.

Conclusions

The VDW.ROTATE files had the highest cyclic fatigue resistance, and the TruNatomy and 2Shape files had the lowest cyclic fatigue resistance in artificial canals at body temperature.

  • 14 View
  • 1 Download
Close layer
The effect of root canal preparation on the surface roughness of WaveOne and WaveOne Gold files: atomic force microscopy study
Taha Özyürek, Koray Yılmaz, Gülşah Uslu, Gianluca Plotino
Restor Dent Endod 2018;43(1):e10.   Published online February 2, 2018
DOI: https://doi.org/10.5395/rde.2018.43.e10
AbstractAbstract PDFPubReaderePub
Objectives

To examine the surface topography of intact WaveOne (WO; Dentsply Sirona Endodontics) and WaveOne Gold (WOG; Dentsply Sirona Endodontics) nickel-titanium rotary files and to evaluate the presence of alterations to the surface topography after root canal preparations of severely curved root canals in molar teeth.

Materials and Methods

Forty-eight severely curved canals of extracted molar teeth were divided into 2 groups (n = 24/each group). In group 1, the canals were prepared using WO and in group 2, the canals were prepared using WOG files. After the preparation of 3 root canals, instruments were subjected to atomic force microscopy analysis. Average roughness and root mean square values were chosen to investigate the surface features of endodontic files. The data was analyzed using one-way analysis of variance and post hoc Tamhane's tests at 5% significant level.

Results

The surface roughness values of WO and WOG files significantly changed after use in root canals (p < 0.05). The used WOG files exhibited higher surface roughness change when compared with the used WO files (p < 0.05).

Conclusions

Using WO and WOG Primary files in 3 root canals affected the surface topography of the files. After being used in root canals, the WOG files showed a higher level of surface porosity value than the WO files.

  • 25 View
  • 0 Download
Close layer

Restor Dent Endod : Restorative Dentistry & Endodontics
Close layer
TOP