Warning: mkdir(): Permission denied in /home/virtual/lib/view_data.php on line 81

Warning: fopen(upload/ip_log/ip_log_2024-12.txt): failed to open stream: No such file or directory in /home/virtual/lib/view_data.php on line 83

Warning: fwrite() expects parameter 1 to be resource, boolean given in /home/virtual/lib/view_data.php on line 84
Safe root canal preparation using reciprocating nickel-titanium instruments
Skip Navigation
Skip to contents

Restor Dent Endod : Restorative Dentistry & Endodontics

OPEN ACCESS

Articles

Page Path
HOME > Restor Dent Endod > Volume 40(3); 2015 > Article
Readers' Forum Safe root canal preparation using reciprocating nickel-titanium instruments
Jung-Hong Ha
Restorative Dentistry & Endodontics 2015;40(3):253-254.
DOI: https://doi.org/10.5395/rde.2015.40.3.253
Published online: June 30, 2015

Kyungpook National University, Korea.

©Copyrights 2015. The Korean Academy of Conservative Dentistry.

This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

  • 18 Views
  • 0 Download
prev next
When I do root canal shaping using reciprocating (NiTi) instrument system, apical blockage often occurs. How can I avoid that?
Apical blockage could lead to the failure of endodontic treatment because of the remaining infected root canal contents such as microorganisms, pulp tissue remnants, and necrotic pulp.1,2
Main causes of canal blockage are the following
1. Accumulation of dentinal chips or debris. The dentinal debris entrapped in the apical canal is lifted up to the coronal part through instruments' flute. In comparison with continuous rotating motion, reciprocating motion shows less ability of debris removal (carrying coronal way) and is prone to canal blockage.3 The accumulation of dentinal debris in the apical root canal results in apical canal blockage.
2. Ledge formation. In curved canal, apical transportation of root canal could not be avoided. When repetitive instrumentations are concentrated on one point (at the same length), ledge is formed due to amplification of transportation. It may get worse when the canal is blocked by packed debris in the canal.
Solutions
1. Establish glide path with rotary instruments such as PathFile/ProGlider, G-file/OneG, and ScoutRace. It could prevent and/or reduce the torsional fracture of shaping instruments and canal aberrations.4,5,6 Also, it could reduce postoperative pain and iatrogenic preiapical periodontitis.7
2. When reciprocating instrument does not advance any more (usually it happens in a curved root canal), you should stop instrumentation and irrigate the root canal copiously to remove the generated dentinal debris. After that, reconfirm apical patency using a small hand file (e.g., size 8 or size 10 K-file) or glide path establishing rotary instruments. This procedure may loosen the packed dentinal debris in apical canal and facilitate debris removal with irrigation. And then, you may restart the instrumentation and can experience advancing of reciprocating file further apically, and sometimes may need to use bigger pecking force momentarily to negotiate the curved area.
Readers' forum is edited by Professor Kyung-Mo Cho (Gangneung-Wonju National University).
  • 1. Seltzer S, Naidorf IJ. Flare-ups in endodontics: I. Etiological factors. J Endod 1985;11:472-478. ArticlePubMed
  • 2. Seltzer S, Naidorf IJ. Flare-ups in endodontics: II. Therapeutic measures. J Endod 1985;11:559-567. ArticlePubMed
  • 3. Bürklein S, Schäfer E. Apically extruded debris with reciprocating single-file and full-sequence rotary instrumentation systems. J Endod 2012;38:850-852. ArticlePubMed
  • 4. Ha JH, Park SS. Influence of glide path on the screw-in effect and torque of nickel-titanium rotary files in simulated resin root canals. Restor Dent Endod 2012;37:215-219. ArticlePubMedPMC
  • 5. Patiño PV, Biedma BM, Liébana CR, Cantatore G, Bahillo JG. The influence of a manual glide path on the separation rate of NiTi rotary instruments. J Endod 2005;31:114-116. ArticlePubMed
  • 6. Ha JH, Cheung GS, Versluis A, Lee CJ, Kwak SW, Kim HC. 'Screw-in' tendency of rotary nickel-titanium files due to design geometry. Int Endod J 2015;48:666-672. ArticlePubMed
  • 7. Pasqualini D, Mollo L, Scotti N, Cantatore G, Castellucci A, Migliaretti G, Berutti E. Postoperative pain after manual and mechanical glide path: a randomized clinical trial. J Endod 2012;38:32-36. PubMed

Tables & Figures

REFERENCES

    Citations

    Citations to this article as recorded by  

      • ePub LinkePub Link
      • Cite
        CITE
        export Copy Download
        Close
        Download Citation
        Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

        Format:
        • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
        • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
        Include:
        • Citation for the content below
        Safe root canal preparation using reciprocating nickel-titanium instruments
        Restor Dent Endod. 2015;40(3):253-254.   Published online June 30, 2015
        Close
      • XML DownloadXML Download
      Safe root canal preparation using reciprocating nickel-titanium instruments
      Safe root canal preparation using reciprocating nickel-titanium instruments

      Restor Dent Endod : Restorative Dentistry & Endodontics
      Close layer
      TOP