Research Article Effect of moisture and drying time on the bond strength of the one-step self-etching adhesive system
Yoon Lee1, Jeong-Won Park2
Restorative Dentistry & Endodontics 2012;37(3):155-159.
DOI: https://doi.org/10.5395/rde.2012.37.3.155
Published online: August 29, 2012

1Department of Conservative Dentistry, Yonsei University Wonju College of Medicine, Wonju, Korea.

2Department of Conservative Dentistry, Yonsei University College of Dentistry, Seoul, Korea.

Correspondence to Jeong-Won Park, DDS, PhD. Associate Professor, Department of Conservative Dentistry, Yonsei University College of Dentistry, 146-92 Dogok-dong, Gangnam-gu, Seoul, Korea 135-720. TEL, +82-2-2019-1350; FAX, +82-2-3463-4052; pjw@yuhs.ac
• Received: April 24, 2012   • Revised: July 5, 2012   • Accepted: July 9, 2012

©Copyights 2012. The Korean Academy of Conservative Dentistry.

This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

  • 18 Views
  • 0 Download
prev next
  • Objectives
    To investigate the effect of dentin moisture degree and air-drying time on dentin-bond strength of two different one-step self-etching adhesive systems.
  • Materials and Methods
    Twenty-four human third molars were used for microtensile bond strength testing of G-Bond and Clearfil S3 Bond. The dentin surface was either blot-dried or air-dried before applying these adhesive agents. After application of the adhesive agent, three different air drying times were evaluated: 1, 5, and 10 sec. Composite resin was build up to 4 mm thickness and light cured for 40 sec with 2 separate layers. Then the tooth was sectioned and trimmed to measure the microtensile bond strength using a universal testing machine. The measured bond strengths were analyzed with three-way ANOVA and regression analysis was done (p = 0.05).
  • Results
    All three factors, materials, dentin wetness and air drying time, showed significant effect on the microtensile bond strength. Clearfil S3 Bond, dry dentin surface and 10 sec air drying time showed higher bond strength.
  • Conclusions
    Within the limitation of this experiment, air drying time after the application of the one-step self-etching adhesive agent was the most significant factor affecting the bond strength, followed by the material difference and dentin moisture before applying the adhesive agent.
The conventional adhesive systems have been multi-bottle types and they had a problem of technique sensitivity.1 Recently, the development of dentin adhesive system is focused on the simplification of the procedure and this can reduce the operator-dependent variability on the bond strength.2 The most simplified adhesive system is the all-in-one type and this includes all components in one bottle. The first one-step self-etching system was composed of two solutions: one part containing organic acid, resin, photoinitiators and stabilizer, and the other part containing water, 2-hydroxylethyl methacrylate (HEMA), and stabilizers.3 Although the manufacturer advertised this product as an all-in-one system, this is a two bottle type one-step self-etching system since the two components should be mixed before use. Later, a true all-in-one system was introduced and every ingredient of the adhesive system was included in one-bottle. These one-step self-etching systems are becoming increasingly more popular and their market share is still growing.4
These early one-step self-etching products were easy to use, but they showed lower bond strength in in vitro experiments and it was reported that the adhesive layer acts as a semi-permeable membrane for water.5 This property was affected by the hydrophilicity of the adhesive agent and HEMA, the main hydrophilic component in the adhesive system. Consequently, a HEMA-free one-step self-etching adhesive system was introduced (G-Bond, GC Corp., Tokyo, Japan). However the lack of HEMA in this product created a drawback known as phase separation. HEMA is the key component for crosslinking the hydrophilic and hydrophobic components of the adhesive system, and this is even more important in one-step self-etching adhesive system, because all components are in one bottle. The manufacturers of Clearfil S3 Bond (Kuraray Medical Inc., Tokyo, Japan) insisted that their product did not show phase separation.
The main advantage of the one-step self-etching systems is that it is less technique sensitive than multi-step systems. However, according to recent studies, the bond strength of these products were affected by several factors: enamel surface treatment, smear layer thickness, grit size of the bur, moisture condition of the adhesive surface, drying time after application of the adhesives, and number of multiple coating.6-9 The moisture control of the adhesive surface can be considered in two parts: the surface moisture before the application of the adhesive agent and the removal of the solvent after application. Acetone and ethanol are the most popular solvents used for the adhesive agents. Usually acetone is more volatile than ethanol and it is easier to remove after application, but there is less chance for ideal handling and this resulted in more technique sensitivity.10 For the etch-and-rinse system, wet adhesive is essential for preventing the collapse of the exposed collagen fibers. However, the acid in the self-etching system is milder than phosphoric acid, and if the adhesive agent is diluted by the excess water on the adhesive surface, it may reduce the bond strength of the self-etching system.9,10 On the contrary, Werner and Tani reported that the dentin wetness and relative humidity did not affect the bond strength of the one-step self-etching adhesive systems.11
The objectives of this experiment were to clarify the effect of the moisture control before and after adhesive agent application with two different one-step self-etching adhesive systems. The null hypothesis was 1) the bond strength of these two systems was not affected by either dentin moisture control or solvent drying time and 2) the bond strength of these two systems was not different.
Twenty-four extracted noncarious human third molars were used and 2 teeth were used for each group in this study. The roots were embedded in a mold with self-cured acrylic resin and they were sectioned and ground with #600 grit sand paper to expose a flat dentin surface perpendicular to the longitudinal axis of the tooth.
Experimental design
Two adhesive systems were used in this experiment (Table 1). Before the application of the adhesive agents, the tooth surface of one group was dried with a strong air blow at 2 cm away from the tooth surface and the other group was blot-dried with a moist cotton ball to provide a moist condition. Then the adhesive agent was applied following the instruction of the manufacturer. After the instructed waiting time, the teeth surfaces were dried for 1, 5, and 10 seconds to remove the water and solvent and light cured for 10 seconds (Figure 1). Two layers of 2 mm-thick composites (Filtek Z350, 3M/ESPE, St. Paul, MN, USA) were built up and cured each layer for 40 seconds with LED light curing unit (Elipar S10, 3M/ESPE) with an intensity of 1,000 mW/cm2.
After composite build-up, the samples were sectioned into 1 mm thick slices with a low-speed diamond saw (Isomet, Buehler, Lake Bluff, IL, USA) and dumbbell shape specimens were prepared with high speed diamond bur. They were immersed in the 37¡É water for 24 hours and fixed on the testing jig with cyanoacrylate (Zapit, Dental Ventures of America Inc., Corona, CA, USA). Microtensile bond strengths were measured with an universal testing machine (EZ-test-500N, Shimadzu Co., Kyoto, Japan) at 1.0 mm/min crosshead speed (n = 10).
Statistical analysis
To evaluate the relation between bond strength and each factor (material, dentin wetness, air drying time) three-way ANOVA at a 0.05 significance level was used and regression analysis was done to compare the effectiveness of these factors with SPSS Ver. 19 (SPSS Inc., Chicago, IL, USA).
Table 2 shows the microtensile bond strength results. Three-way ANOVA revealed significant differences in the effects of materials (F = 39.7, p < 0.05), dentin wetness before the adhesive agent application (F = 8.8, p < 0.05) and air drying time after the adhesive agent application (F = 237.8, p < 0.05). No interactions were found among these three factors.
According to the results of this experiment, Clearfil S3 Bond showed higher bond strength than G-Bond and for the dentin wetness (p < 0.05), dry group showed higher bond strength than blot dry group (p < 0.05). For the air drying time, 10 seconds showed highest bond strength and followed by 5 and 1 seconds (p < 0.05). The regression analysis showed that the air drying time was the most critical factor on the bond strength, followed by the materials and dentin wetness (Table 3).
For the lastest decades, one-step self-etching adhesive systems have been developed and the advantage of this system is the relatively simple procedure, which minimizes the steps of the adhesive and reduces the technique sensitivity.12 In in vitro experiments, the moisture control on the tooth surface is relatively simple, but in clinical situations, it is not easy because cavity geometry is more complex and it is difficult to obtain water tight seal during the restorative procedure, especially when the cavity margin is located subgingivally. Thus revealing the effect of the moisture on the bond strength of the adhesive agent is important not only for the investigators but also for the clinicians. Following the result of this experiment, the adhesive agent, the moisture conditions before the application of the adhesive agents and the air drying time affected on the bond strength and the null hypothesis was rejected.
In this experiment, air drying time was the most important factor on the bond strength. Most self-etching system has water in the solvent to represent the acidity. Therefore if it is not removed completely, it is entrapped within the adhesive layer, and this results in catastrophic reduction of the bond strength, which is consistent with other experiments.13,14 In G-Bond, one second air drying was not enough even though this product used acetone as a solvent. In previous studies, when this adhesive agent was not dried completely with strong air, water droplet remained in the adhesive layer, and this reduced the bond strength and increased the nanoleakage.15,16 The bond strength increased when we dried the adhesive surface for 10 seconds, and this means that even five seconds was not enough time to remove the water and organic solvent.
Next significant factor affecting the bond strength was the material difference. In this experiment, Clearfil S3 Bond showed higher bond strength than G-Bond. Comparing the component of these two adhesive systems, Clearfil S3 Bond contains HEMA to prevent phase separation, 10-MDP as a functional monomer, and ethanol as the solvent. On the contrary, G-Bond is HEMA-free, and it contains 4-MET as a functional monomer and acetone as the solvent. All of these differences can influence the bond strength. Landuyt et al. reported that when 10% HEMA was added in adhesives, the bond strength of the one-step self-etching adhesive was improved.17 Acetone, used in G-Bond, is known as a strong organic solvent for the functional monomer and hydrophobic resin monomer, and also as a good water chaser. However, this type of solvent is known to be more technique sensitive than ethanol.5,18 In a view point of functional monomer, Tsuchimoto et al. reported that 10-MDP showed higher bond strength than 4-MET.19 The combination of these factors probably resulted in the higher performance of Clearfil S3 Bond. The moisture condition of the tooth surface also affected the bond strength of one-step self-etching systems. This can be explained by the fact that the moisture on the dentin surface may dilute the adhesives, thus negating the etching effect of the adhesives. Such imperfect etching might decrease the potential for hybridization and finally lead to failure of the resin composite. Another explanation for the decrease in the dentin adhesive strength might be the imperfect polymerization of adhesives due to the excessive water present.9
When we compare the bond strength of the two adhesive systems, if the moisture control was ideal, that is, dry dentin surface before applying the adhesive agent and 10 seconds air dry performed, G-Bond and Clearfil S3 Bond showed similar results, which were 37.0¡¾4.9 and 38.2¡¾5.0, respectively. However, if G-Bond was applied on a wet dentin surface, the decrease in the bond strength was greater than Clearfil S3 Bond. This means that the G-Bond is more technique sensitive, and thus the operator should be more cautious when using this in complex clinical situations.
Within the limitation of this experiment, air drying time after the application of the one-step self-etching adhesive agent was the most significant factor affecting the bond strength, followed by the adhesive composition and dentin moisture before applying the bond.

This research was supported by the grant of 2007 Yonsei university school of dentistry research funds (7-2007-0070).

No potential conflict of interest relevant to this article was reported.

  • 1. Frankenberger R, Krämer N, Petschelt A. Technique sensitivity of dentin bonding: effect of application mistakes on bond strength and marginal adaptation. Oper Dent 2000;25:324-330. PubMed
  • 2. Soderholm KJ, Soares F, Argumosa M, Loveland C, Bimstein E, Guelmann M. Shear bond strength of one etch-and-rinse and five self-etching dental adhesives when used by six operators. Acta Odontol Scand 2008;66:243-249. ArticlePubMed
  • 3. Perdigão J. New developments in dental adhesion. Dent Clin North Am 2007;51:333-357. PubMed
  • 4. Van Landuyt KL, Mine A, De Munck J, Jaecques S, Peumans M, Lambrechts P, Van Meerbeek B. Are one-step adhesives easier to use and better performing? Multifactorial assessment of contemporary one-step self-etching adhesives. J Adhes Dent 2009;11:175-190. PubMed
  • 5. Van Meerbeek B, De Munck J, Yoshida Y, Inoue S, Vargas M, Vijay P, Van Landuyt K, Lambrechts P, Vanherle G. Buonocore memorial lecture. Adhesion to enamel and dentin: current status and future challenges. Oper Dent 2003;28:215-235. PubMed
  • 6. Yiu CK, Hiraishi N, King NM, Tay FR. Effect of dentinal surface preparation on bond strength of self-etching adhesives. J Adhes Dent 2008;10:173-182. PubMed
  • 7. Kitayama S, Nikaido T, Ikeda M, Foxton RM, Tagami J. Enamel bonding of self-etch and phosphoric acid-etch orthodontic adhesive systems. Dent Mater J 2007;26:135-143. PubMed
  • 8. Chiba Y, Rikuta A, Yasuda G, Yamamoto A, Takamizawa T, Kurokawa H, Ando S, Miyazaki M. Influence of moisture conditions on dentin bond strength of single-step self-etch adhesive systems. J Oral Sci 2006;48:131-137. ArticlePubMed
  • 9. Di Hipólito V, de Goes MF, Carrilho MR, Chan DC, Daronch M, Sinhoreti MA. SEM evaluation of contemporary self-etching primers applied to ground and unground enamel. J Adhes Dent 2005;7:203-211. PubMed
  • 10. Jin MU, Kim YK, Park JW. The influence of moisture control on bond strength of composite resin treated with self-etching adhesive system. J Korean Acad Conserv Dent 2002;27:363-369.Article
  • 11. Werner JF, Tani C. Effect of relative humidity on bond strength of self-etching adhesives to dentin. J Adhes Dent 2002;4:277-282. PubMed
  • 12. Nakaoki Y, Sasakawa W, Horiuchi S, Nagano F, Ikeda T, Tanaka T, Inoue S, Uno S, Sano H, Sidhu SK. Effect of double-application of all-in-one adhesives on dentin bonding. J Dent 2005;33:765-772. ArticlePubMed
  • 13. Jacobsen T, Finger WJ, Kanehira M. Air-drying time of self-etching adhesives vs adhesive efficacy. J Adhes Dent 2006;8:387-392. PubMed
  • 14. Chiba Y, Yamaguchi K, Miyazaki M, Tsubota K, Takamizawa T, Moore BK. Effect of air-drying time of single-application self-etch adhesives on dentin bond strength. Oper Dent 2006;31:233-239. ArticlePubMedPDF
  • 15. Van Landuyt KL, Snauwaert J, De Munck J, Coutinho E, Poitevin A, Yoshida Y, Suzuki K, Lambrechts P, Van Meerbeek B. Origin of interfacial droplets with one-step adhesives. J Dent Res 2007;86:739-744. PubMed
  • 16. Hiraishi N, Breschi L, Prati C, Ferrari M, Tagami J, King NM. Technique sensitivity associated with air-drying of HEMA-free, single-bottle, one-step self-etch adhesives. Dent Mater 2007;23:498-505. ArticlePubMed
  • 17. Van Landuyt KL, Snauwaert J, Peumans M, De Munck J, Lambrechts P, Van Meerbeek B. The role of HEMA in one-step self-etch adhesives. Dent Mater 2008;24:1412-1419. ArticlePubMed
  • 18. Tay FR, Gwinnett JA, Wei SH. Micromorphological spectrum from overdrying to overwetting acid-conditioned dentin in water-free acetone-based, single-bottle primer/adhesives. Dent Mater 1996;12:236-244. ArticlePubMed
  • 19. Tsuchimoto Y, Yoshida Y, Mine A, Nakamura M, Nishiyama N, Van Meerbeek B, Suzuki K, Kuboki T. Effect of 4-MET- and 10-MDP-based primers on resin adhesive to titanium. Dent Mater J 2006;25:120-124. PubMed
Figure 1
The schematic view of the experimental design. Wetness of the tooth surface was divided into dry and blot dry groups and drying times after adhesive application were into 1, 5 and 10 seconds groups for each adhesive agent.
rde-37-155-g001.jpg
Table 1
The adhesive systems used for this experiment and their instructions for use

4-MET, 4-methacryloyloxyethyl trimellitate; UDMA, urethane dimethacrylate; DMA, dimethacrylate; 10-MDP, 10-methacryloxydecyl di-hydrogen phosphate; HEMA, 2-hydroxyethyl methacrylate; bis-GMA, 2,2 bis[4-(2-hydroxy-3-methacryloyloxypropoxy)phenyl] propane.

rde-37-155-i001.jpg
Table 2
The microtensile bond strength of this experiment
rde-37-155-i002.jpg
Table 3
The regression analysis results of this experiment.
rde-37-155-i003.jpg

Tables & Figures

REFERENCES

    Citations

    Citations to this article as recorded by  

      • ePub LinkePub Link
      • Cite
        CITE
        export Copy Download
        Close
        Download Citation
        Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

        Format:
        • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
        • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
        Include:
        • Citation for the content below
        Effect of moisture and drying time on the bond strength of the one-step self-etching adhesive system
        Restor Dent Endod. 2012;37(3):155-159.   Published online August 29, 2012
        Close
      • XML DownloadXML Download
      Figure
      • 0
      Related articles
      Effect of moisture and drying time on the bond strength of the one-step self-etching adhesive system
      Image
      Figure 1 The schematic view of the experimental design. Wetness of the tooth surface was divided into dry and blot dry groups and drying times after adhesive application were into 1, 5 and 10 seconds groups for each adhesive agent.
      Effect of moisture and drying time on the bond strength of the one-step self-etching adhesive system

      The adhesive systems used for this experiment and their instructions for use

      4-MET, 4-methacryloyloxyethyl trimellitate; UDMA, urethane dimethacrylate; DMA, dimethacrylate; 10-MDP, 10-methacryloxydecyl di-hydrogen phosphate; HEMA, 2-hydroxyethyl methacrylate; bis-GMA, 2,2 bis[4-(2-hydroxy-3-methacryloyloxypropoxy)phenyl] propane.

      The microtensile bond strength of this experiment

      The regression analysis results of this experiment.

      Table 1 The adhesive systems used for this experiment and their instructions for use

      4-MET, 4-methacryloyloxyethyl trimellitate; UDMA, urethane dimethacrylate; DMA, dimethacrylate; 10-MDP, 10-methacryloxydecyl di-hydrogen phosphate; HEMA, 2-hydroxyethyl methacrylate; bis-GMA, 2,2 bis[4-(2-hydroxy-3-methacryloyloxypropoxy)phenyl] propane.

      Table 2 The microtensile bond strength of this experiment

      Table 3 The regression analysis results of this experiment.