Skip Navigation
Skip to contents

Restor Dent Endod : Restorative Dentistry & Endodontics

OPEN ACCESS

Search

Page Path
HOME > Search
2 "internal gap"
Filter
Filter
Article category
Keywords
Publication year
Authors
Research Article
Marginal and internal fit of nano-composite CAD/CAM restorations
So-Hyun Park, Yeon-Jee Yoo, Yoo-Jin Shin, Byeong-Hoon Cho, Seung-Ho Baek
Restor Dent Endod 2016;41(1):37-43.   Published online January 19, 2016
DOI: https://doi.org/10.5395/rde.2016.41.1.37
AbstractAbstract PDFPubReaderePub
Objectives

The purpose of this study was to compare the marginal and internal fit of nano-composite CAD-CAM restorations.

Materials and Methods

A full veneer crown and an mesio-occluso-distal (MOD) inlay cavity, which were prepared on extracted human molars, were used as templates of epoxy resin replicas. The prepared teeth were scanned and CAD-CAM restorations were milled using Lava Ultimate (LU) and experimental nano-composite CAD/CAM blocks (EB) under the same milling parameters. To assess the marginal and internal fit, the restorations were cemented to replicas and were embedded in an acrylic mold for sectioning at 0.5 mm intervals. The measured gap data were pooled according to the block types and measuring points for statistical analysis.

Results

Both the block type and measuring point significantly affected gap values, and their interaction was significant (p = 0.000). In crowns and inlays made from the two blocks, gap values were significantly larger in the occlusal area than in the axial area, while gap values in the marginal area were smallest (p < 0.001). Among the blocks, the restorations milled from EB had a significantly larger gap at all measuring points than those milled from LU (p = 0.000).

Conclusions

The marginal and internal gaps of the two nano-composite CAD/CAM blocks differed according to the measuring points. Among the internal area of the two nano-composite CAD/CAM restorations, occlusal gap data were significantly larger than axial gap data. The EB crowns and inlays had significantly larger gaps than LU restorations.

  • 24 View
  • 0 Download
Close layer
Original Article
Influence of three different preparation designs on the marginal and internal gaps of CEREC3 CAD/CAM inlays
Deog-Gyu Seo, Young-Ah Yi, Yoon Lee, Byoung-Duck Roh
J Korean Acad Conserv Dent 2009;34(3):177-183.   Published online May 31, 2009
DOI: https://doi.org/10.5395/JKACD.2009.34.3.177
AbstractAbstract PDFPubReaderePub

The aim of this study was to evaluate the marginal and internal gaps in CEREC3 CAD/CAM inlays of three different preparation designs. CEREC3 Inlays of three different preparation designs (n = 10) were fabricated according to Group I-conventional functional cusp capping/shoulder preparation, Group II-horizontal reduction of cusps and Group III-complete reduction of cusps/shoulder preparation. After cementation of inlays, the bucco-lingual cross section was performed through the center of tooth. Cross section images of 20 magnifications were obtained through the stereomicroscope. The gaps were measured using the Leica application suite software at each reference point. Statistical analysis was performed using one-way ANOVA and Tukey's test (α<0.05).

The marginal gaps ranged from 80.0 to 97.8 µm for Group I, 42.0 to 194.8 µm for Group II, 51.0 to 80.2 µm for Group III. The internal gaps ranged from 90.5 to 304.1 µm for Group I, 80.0 to 274.8 µm for Group II, 79.7 to 296.7 µm for Group III. The gaps of each group were the smallest on the margin and the largest on the horizontal wall. For the CEREC3 CAD/CAM inlays, the simplified designs (groups II and III) did not demonstrate superior results compared to the traditional cusp capping design (group I).

  • 25 View
  • 0 Download
Close layer

Restor Dent Endod : Restorative Dentistry & Endodontics
Close layer
TOP