Skip Navigation
Skip to contents

Restor Dent Endod : Restorative Dentistry & Endodontics

OPEN ACCESS

Search

Page Path
HOME > Search
2 "Push-out test"
Filter
Filter
Article category
Keywords
Publication year
Authors
Original Articles
Effect of curing methods of resin cements on bond strength and adhesive interface of post
Mun-Hong Kim, Hae-Jung Kim, Young-Gon Cho
J Korean Acad Conserv Dent 2009;34(2):103-112.   Published online March 31, 2009
DOI: https://doi.org/10.5395/JKACD.2009.34.2.103
AbstractAbstract PDFPubReaderePub

The purpose of this study was to compare the effect of curing methods of adhesive resins and resin cements in the root canal. Crown portions of 32 single-rooted mandibular premolars were removed. Routine endodontic treatment was done, and 9 mm deep post spaces were prepared within root canals. No. 3 FRC Postec posts (Ivoclar-Vivadent AG, Liechtenstein) were cemented in the post spaces by self-(SC) or light-curing (LC) using two dual-cured adhesives (Adper Scotchbond multi-purpose plus and Exite DSC )and resin cements (RelyX ARC and Variolink II). They were assigned to 4 groups (n=8); R-SC, R-LC, V-SC, V-LC group.

After stored in distilled water for 24 hours, each root was transversally sectioned with 1.5 mm thick and made three slices. The specimens were subjected to push-out test in a universal testing machine (EZ Test, Shimadzu Co., Japan) with a crosshead speed of 1 mm/min. The data were analyzed with repeated ANOVA and one-way.

ANOVA. Also the interface of post-resin cement and resin cement-canal wall of each group was observed under FE-SEM.

When fiber posts were cemented into the root canal using total-etch adhesives, the bond strength and adaptation between post and root canal dentin was affected by curing method. Self-cure of adhesives and resin cements showed higher bond strength and closer adaptation than light-cure of them.

Citations

Citations to this article as recorded by  
  • Retentive strength of different intracanal posts in restorations of anterior primary teeth: anin vitrostudy
    Mahtab Memarpour, Fereshteh Shafiei, Maryam Abbaszadeh
    Restorative Dentistry & Endodontics.2013; 38(4): 215.     CrossRef
  • Effect of surface treatment of FRC-Post on bonding strength to resin cements
    Chan-Hyun Park, Se-Hee Park, Jin-Woo Kim, Kyung-Mo Cho
    Journal of Korean Academy of Conservative Dentistry.2011; 36(2): 125.     CrossRef
  • Effect of surface treatments of fiber posts on bond strength to composite resin cores
    Hye-Jo Keum, Hyun-Mi Yoo
    Journal of Korean Academy of Conservative Dentistry.2010; 35(3): 173.     CrossRef
  • Comparison of push-out bond strength of post according to cement application methods
    Seo-Ryeong Kim, Jiwan Yum, Jeong-Kil Park, Bock Hur, Hyeon-Cheol Kim
    Journal of Korean Academy of Conservative Dentistry.2010; 35(6): 479.     CrossRef
  • 168 View
  • 1 Download
  • 4 Crossref
Close layer
Comparison of bond strength of a fiber post cemented with various resin cements
Hyun-A Lee, Young-Gon Cho
J Korean Acad Conserv Dent 2008;33(6):499-506.   Published online November 30, 2008
DOI: https://doi.org/10.5395/JKACD.2008.33.6.499
AbstractAbstract PDFPubReaderePub

The purpose of this study was to compare the push-out strength of a fiber post cemented with various resin cements. Newly extracted 36 human mandibular premolars which had single root canal were selected and their crown portions were removed. The root canal was instrumented using PROTAPER™ system and obturated using continuous wave technique. In each root, a 9-mm deep post space was prepared. #2 translucent fiber post (DT Light post, Bisco Inc., Schaumburg, IL, U.S.A.) was cemented using injection technique with Uni-dose needle tip (Bisco) and six different resin cements. The tested resin cements were Duo-Link (Bisco Inc., Schaumburg, IL, U.S.A.), Variolink II (Ivoclar-Vivadent AG, Schann, Liechtenstein), Panavia F (Kuraray Medical Inc., Okayama, Japan), Multilink Automix (Ivoclar-Vivadent AG, Schann, Liechtenstein), RelyX Unicem (3M ESPE Dental Products, St. Paul, MN, U.S.A.), and Maxcem (Kerr Co., CA, U.S.A.). After storage in distilled water for 24 hours, each root was transversally sectioned into approximately 1-mm thick sections. This procedure resulted in 6 serial sections per root. Push-out test was performed using a universal testing machine (EZ Test, Shimadzu Co.) with a crosshead speed of 1 mm/min. The data were analyzed with one-way ANOVA and Tukey HSD (p=0.05).

The push-out strength of the groups which cemented fiber post with Panavia F and Multilink Automix were lower than those of the other groups. But, there were no statistically significant difference among groups at a probability level of 0.05.

Citations

Citations to this article as recorded by  
  • Effect of surface treatments of fiber posts on bond strength to composite resin cores
    Hye-Jo Keum, Hyun-Mi Yoo
    Journal of Korean Academy of Conservative Dentistry.2010; 35(3): 173.     CrossRef
  • Comparison of push-out bond strength of post according to cement application methods
    Seo-Ryeong Kim, Jiwan Yum, Jeong-Kil Park, Bock Hur, Hyeon-Cheol Kim
    Journal of Korean Academy of Conservative Dentistry.2010; 35(6): 479.     CrossRef
  • Effect of dentin surface wetness on tensile bond strength of self adhesive resin cements
    Sung-Young Yoon, Se-Hee Park, Jin-Woo Kim, Kyung-Mo Cho
    Journal of Korean Academy of Conservative Dentistry.2009; 34(2): 113.     CrossRef
  • 178 View
  • 0 Download
  • 3 Crossref
Close layer

Restor Dent Endod : Restorative Dentistry & Endodontics
Close layer
TOP