Skip Navigation
Skip to contents

Restor Dent Endod : Restorative Dentistry & Endodontics

OPEN ACCESS

Search

Page Path
HOME > Search
3 "ProTaper Gold"
Filter
Filter
Article category
Keywords
Publication year
Authors
Research Articles
Comparison of vibration characteristics of file systems for root canal shaping according to file length
Seong-Jun Park, Se-Hee Park, Kyung-Mo Cho, Hyo-Jin Ji, Eun-Hye Lee, Jin-Woo Kim
Restor Dent Endod 2020;45(4):e51.   Published online October 14, 2020
DOI: https://doi.org/10.5395/rde.2020.45.e51
AbstractAbstract PDFPubReaderePub
Objectives

No studies have yet assessed vibration characteristics according to endodontic file length. Accordingly, the objective of the present study was to examine the vibration characteristics according to nickel-titanium file length and to compare these characteristics between different file systems.

Materials and Methods

A total of 45 root canal models were divided into 3 experimental groups (n = 15 each) based on the file system used (ProTaper Gold [PTG], ProTaper Next, or WaveOne Gold [WOG]). Each experimental group was further divided into 3 subgroups according to file length (21, 25, or 31 mm). An electric motor (X-SMART PLUS) was used in the experiment. For each file system, vibrations generated when using a size 25 file were measured and used to calculate the average vibration acceleration. The differences in vibrations were analyzed using 1-way analysis of variance and the Scheffé post hoc test with a confidence interval of 95%.

Results

In the PTG file system, significantly lower vibration acceleration was observed when using a 21-mm file than when using a 31-mm file. In the WOG file system, significantly stronger vibration acceleration was observed when using a 31-mm file than when using 21- or 25-mm files. Regardless of the file length, the WOG group exhibited significantly stronger vibration acceleration than the other 2 experimental groups.

Conclusions

In clinical practice, choosing a file with the shortest length possible could help reduce vibrations. Additionally, consideration should be given to vibrations that could be generated when using WOG files with reciprocating motion.

Citations

Citations to this article as recorded by  
  • Comparison vibration characteristics of several wireless endodontic handpieces
    Bo-Kyung Lee, Yoon Lee, Se-Hee Park, Kyung-Mo Cho, Jin-Woo Kim
    Journal of Dental Rehabilitation and Applied Science.2022; 38(2): 81.     CrossRef
  • 194 View
  • 2 Download
  • 1 Crossref
Close layer
Cyclic fatigue, bending resistance, and surface roughness of ProTaper Gold and EdgeEvolve files in canals with single- and double-curvature
Wafaa A. Khalil, Zuhair S. Natto
Restor Dent Endod 2019;44(2):e19.   Published online April 26, 2019
DOI: https://doi.org/10.5395/rde.2019.44.e19
AbstractAbstract PDFPubReaderePub
Objectives

The purpose of this study was to evaluate the cyclic fatigue, bending resistance, and surface roughness of EdgeEvolve (EdgeEndo) and ProTaper Gold (Dentsply Tulsa Dental Specialties) nickel-titanium (NiTi) rotary files.

Materials and Methods

The instruments (n = 15/each) were tested for cyclic fatigue in single- (60° curvature, 5-mm radius) and double-curved (coronal curvature 60°, 5-mm radius, and apical curvature of 30° and 2-mm radius) artificial canals. The number of cycles to fracture was calculated. The bending resistance of both files were tested using a universal testing machine where the files were bent until reach 45°. Scanning electron microscopy and x-ray energy-dispersive spectrometric analysis were used for imaging the fractured segments, while the atomic force microscope was used to quantify the surface roughness average (Ra).

Results

EdgeEvolve files exhibited higher cyclic fatigue resistance than ProTaper Gold files in single- and double-curved canals (p < 0.05) and both files were more resistant to cyclic fatigue in single-curved canals than double-curved canals (p < 0.05). EdgeEvolve files exhibited significantly more flexibility than did ProTaper Gold files (p < 0.05). Both files had approximately similar Ni and Ti contents (p > 0.05). EdgeEvolve files showed significantly lower Ra values than ProTaper Gold files (p < 0.05).

Conclusions

Within the limitation of this study, EdgeEvolve files exhibited significantly higher cyclic fatigue resistance than ProTaper Gold files in both single- and double-curved canals.

Citations

Citations to this article as recorded by  
  • An in vitro comparison of alterations in surface topographies of three different rotary files after root canal preparation with different irrigating solutions: Atomic force microscopic study
    PremSai Parepalli, TB. V G. Raju, PKrishna Prasad, GowtamDev Dondapati, VenkataSrija Kintada, Alekhya Mediboyina
    Journal of Conservative Dentistry.2023; 26(3): 299.     CrossRef
  • Assessment of surface topographic changes of nickel–titanium rotary endodontic file at repeated usage: An in vitro study
    E. Viswas, VSS Krishna, E. Sridevi, A. J. Sai Sankar, K. Siva Sankar, B. Nagesh
    Endodontology.2023; 35(2): 149.     CrossRef
  • Cyclic Fatigue Resistance and Surface Roughness of Rotary NiTi Instruments after Simulated Clinical Use in Curved Root Canals – An Atomic Force Microscopy Study
    Raksha Bhat, Arjun Kini, Preethesh Shetty, Payalben Kansara, Bapanaiah Penugonda
    Pesquisa Brasileira em Odontopediatria e Clínica Integrada.2022;[Epub]     CrossRef
  • Metallurgical Tests in Endodontics: A Narrative Review
    Alessio Zanza, Marco Seracchiani, Rodolfo Reda, Gabriele Miccoli, Luca Testarelli, Dario Di Nardo
    Bioengineering.2022; 9(1): 30.     CrossRef
  • Influence of nickel-titanium rotary systems with varying cross-sectional, pitch, and rotational speed on deflection and cyclic fatigue: a finite element analysis study
    Wignyo Hadriyanto, Lukita Wardani, Christina Nugrohowati, Ananto Alhasyimi, Rachmat Sriwijaya, Margareta Rinastiti, Widowati Siswomihardjo, Gunadi, T. Yamada, A.A.C. Pramana, Y. Ophinni, A. Gusnanto, W.A. Kusuma, J. Yunus, Afiahayati, R. Dharmastiti, T.
    BIO Web of Conferences.2021; 41: 05005.     CrossRef
  • Can the Separated Instrument be Removed From the Root Canal System out by Magnetism? A Hypothesis
    Mohammad Daryaeian, Sanjay Miglani, AbdolMahmood Davarpanah, Hyeon-Cheol Kim, Mohsen Ramazani
    Dental Hypotheses.2019; 10(4): 108.     CrossRef
  • Resistance to cyclic fatigue of reciprocating instruments determined at body temperature and phase transformation analysis
    Raymond Scott, Ana Arias, José C. Macorra, Sanjay Govindjee, Ove A. Peters
    Australian Endodontic Journal.2019; 45(3): 400.     CrossRef
  • 219 View
  • 4 Download
  • 7 Crossref
Close layer
Comparison of canal transportation in simulated curved canals prepared with ProTaper Universal and ProTaper Gold systems
Emmanuel João Nogueira Leal Silva, Brenda Leite Muniz, Frederico Pires, Felipe Gonçalves Belladonna, Aline Almeida Neves, Erick Miranda Souza, Gustavo De-Deus
Restor Dent Endod 2016;41(1):1-5.   Published online February 4, 2016
DOI: https://doi.org/10.5395/rde.2016.41.1.1
AbstractAbstract PDFPubReaderePub
Objectives

The purpose of this study was to assess the ability of ProTaper Gold (PTG, Dentsply Maillefer) in maintaining the original profile of root canal anatomy. For that, ProTaper Universal (PTU, Dentsply Maillefer) was used as reference techniques for comparison.

Materials and Methods

Twenty simulated curved canals manufactured in clear resin blocks were randomly assigned to 2 groups (n = 10) according to the system used for canal instrumentation: PTU and PTG groups, upto F2 files (25/0.08). Color stereomicroscopic images from each block were taken exactly at the same position before and after instrumentation. All image processing and data analysis were performed with an open source program (FIJI). Evaluation of canal transportation was obtained for two independent canal regions: straight and curved levels. Student's t test was used with a cut-off for significance set at α = 5%.

Results

Instrumentation systems significantly influenced canal transportation (p < 0.0001). A significant interaction between instrumentation system and root canal level (p < 0.0001) was found. PTU and PTG systems produced similar canal transportation at the straight part, while PTG system resulted in lower canal transportation than PTU system at the curved part. Canal transportation was higher at the curved canal portion (p < 0.0001).

Conclusions

PTG system produced overall less canal transportation in the curved portion when compared to PTU system.

Citations

Citations to this article as recorded by  
  • Shaping, and disinfecting abilities of ProTaper Universal, ProTaper Gold, and Twisted Files: A correlative microcomputed tomographic and bacteriologic analysis
    Malavika Sivakumar, Ruchika Roongta Nawal, Sangeeta Talwar, CP Baveja, Rega Kumar, Sudha Yadav, S Santosh Kumar
    Endodontology.2023; 35(1): 54.     CrossRef
  • Advancing Nitinol: From heat treatment to surface functionalization for nickel–titanium (NiTi) instruments in endodontics
    Wai-Sze Chan, Karan Gulati, Ove A. Peters
    Bioactive Materials.2023; 22: 91.     CrossRef
  • Comparative Evaluation of Root Canal Centering Ability of Two Heat-treated Single-shaping NiTi Rotary Instruments in Simulated Curved Canals: An In Vitro Study
    Preethi Varadan, Chakravarthy Arumugam, Athira Shaji, R R Mathan
    World Journal of Dentistry.2023; 14(6): 535.     CrossRef
  • An Appraisal on Newer Endodontic File Systems: A Narrative Review
    Shalini Singh, Kailash Attur, Anjali Oak, Mohammed Mustafa, Kamal Kumar Bagda, Nishtha Kathiria
    The Journal of Contemporary Dental Practice.2023; 23(9): 944.     CrossRef
  • Shaping ability of modern Nickel–Titanium rotary systems on the preparation of printed mandibular molars
    Seda Falakaloglu, Emmanuel Silva, Burcu Topal, Emre İriboz, Mustafa Gündoğar
    Journal of Conservative Dentistry.2022; 25(5): 498.     CrossRef
  • An Investigation of the Accuracy and Reproducibility of 3D Printed Transparent Endodontic Blocks
    Martin Smutný, Martin Kopeček, Aleš Bezrouk
    Acta Medica (Hradec Kralove, Czech Republic).2022; 65(2): 59.     CrossRef
  • Nitinol Type Alloys General Characteristics and Applications in Endodontics
    Leszek A. Dobrzański, Lech B. Dobrzański, Anna D. Dobrzańska-Danikiewicz, Joanna Dobrzańska
    Processes.2022; 10(1): 101.     CrossRef
  • Impact of Endodontic Kinematics on Stress Distribution During Root Canal Treatment: Analysis of Photoelastic Stress
    Shelyn Akari Yamakami, Julia Adornes Gallas, Igor Bassi Ferreira Petean, Aline Evangelista Souza-Gabriel, Manoel Sousa-Neto, Ana Paula Macedo, Regina Guenka Palma-Dibb
    Journal of Endodontics.2022; 48(2): 255.     CrossRef
  • Shaping ability of ProTaper Gold and WaveOne Gold nickel-titanium rotary instruments in simulated S-shaped root canals
    Lu Shi, Junling Zhou, Jie Wan, Yunfei Yang
    Journal of Dental Sciences.2022; 17(1): 430.     CrossRef
  • A Comparative Study of Two Martensitic Alloy Systems in Endodontic Files Carried out by Unskilled Hands
    Juan Algar, Alejandra Loring-Castillo, Ruth Pérez-Alfayate, Carmen Martín Carreras-Presas, Ana Suárez
    Applied Sciences.2022; 12(12): 6289.     CrossRef
  • Quantitative evaluation of apically extruded debris using TRUShape, TruNatomy, and WaveOne Gold in curved canals
    Nehal Nabil Roshdy, Reham Hassan
    BDJ Open.2022;[Epub]     CrossRef
  • Comparison of Canal Transportation, Separation Rate, and Preparation Time between One Shape and Neoniti (Neolix): An In Vitro CBCT Study
    Maryam Kuzekanani, Faranak Sadeghi, Nima Hatami, Maryam Rad, Mansoureh Darijani, Laurence James Walsh, Sivakumar Nuvvula
    International Journal of Dentistry.2021; 2021: 1.     CrossRef
  • Shaping ability of ProTaper Gold, One Curve, and Self-Adjusting File systems in severely curved canals: A cone-beam computed tomography study
    MeenuG Singla, Hemanshi Kumar, Ritika Satija
    Journal of Conservative Dentistry.2021; 24(3): 271.     CrossRef
  • Cone-beam computed tomographic analysis of apical transportation and centering ratio of ProTaper and XP-endo Shaper NiTi rotary systems in curved canals: an in vitro study
    Hamed Karkehabadi, Zeinab Siahvashi, Abbas Shokri, Nasrin Haji Hasani
    BMC Oral Health.2021;[Epub]     CrossRef
  • Mechanical Tests, Metallurgical Characterization, and Shaping Ability of Nickel-Titanium Rotary Instruments: A Multimethod Research
    Emmanuel J.N.L. Silva, Jorge N.R. Martins, Carolina O. Lima, Victor T.L. Vieira, Francisco M. Braz Fernandes, Gustavo De-Deus, Marco A. Versiani
    Journal of Endodontics.2020; 46(10): 1485.     CrossRef
  • Micro-computed tomographic evaluation of a new system for root canal filling using calcium silicate-based root canal sealers
    Mario Tanomaru-Filho, Fernanda Ferrari Esteves Torres, Jader Camilo Pinto, Airton Oliveira Santos-Junior, Karina Ines Medina Carita Tavares, Juliane Maria Guerreiro-Tanomaru
    Restorative Dentistry & Endodontics.2020;[Epub]     CrossRef
  • Comparison of vibration characteristics of file systems for root canal shaping according to file length
    Seong-Jun Park, Se-Hee Park, Kyung-Mo Cho, Hyo-Jin Ji, Eun-Hye Lee, Jin-Woo Kim
    Restorative Dentistry & Endodontics.2020;[Epub]     CrossRef
  • New thermomechanically treated NiTi alloys – a review
    J. Zupanc, N. Vahdat‐Pajouh, E. Schäfer
    International Endodontic Journal.2018; 51(10): 1088.     CrossRef
  • Shaping ability of four root canal instrumentation systems in simulated 3D-printed root canal models
    David Christofzik, Andreas Bartols, Mahmoud Khaled Faheem, Doreen Schroeter, Birte Groessner-Schreiber, Christof E. Doerfer, Cyril Charles
    PLOS ONE.2018; 13(8): e0201129.     CrossRef
  • OPEN-SOURCE SOFTWARE IN DENTISTRY: A SYSTEMATIC REVIEW
    Małgorzata Chruściel-Nogalska, Tomasz Smektała, Marcin Tutak, Katarzyna Sporniak-Tutak, Raphael Olszewski
    International Journal of Technology Assessment in Health Care.2017; 33(4): 487.     CrossRef
  • Mechanical Properties of Various Heat-treated Nickel-titanium Rotary Instruments
    Hye-Jin Goo, Sang Won Kwak, Jung-Hong Ha, Eugenio Pedullà, Hyeon-Cheol Kim
    Journal of Endodontics.2017; 43(11): 1872.     CrossRef
  • A comparison of the shaping ability of three nickel-titanium rotary instruments: a micro-computed tomography study via a contrast radiopaque technique in vitro
    Zhao Wei, Zhi Cui, Ping Yan, Han Jiang
    BMC Oral Health.2017;[Epub]     CrossRef
  • Root Canal Transportation and Centering Ability of Nickel-Titanium Rotary Instruments in Mandibular Premolars Assessed Using Cone-Beam Computed Tomography
    Iussif Mamede-Neto, Alvaro Henrique Borges, Orlando Aguirre Guedes, Durvalino de Oliveira, Fábio Luis Miranda Pedro, Carlos Estrela
    The Open Dentistry Journal.2017; 11(1): 71.     CrossRef
  • Blue Thermomechanical Treatment Optimizes Fatigue Resistance and Flexibility of the Reciproc Files
    Gustavo De-Deus, Emmanuel João Nogueira Leal Silva, Victor Talarico Leal Vieira, Felipe Gonçalves Belladonna, Carlos Nelson Elias, Gianluca Plotino, Nicola Maria Grande
    Journal of Endodontics.2017; 43(3): 462.     CrossRef
  • 299 View
  • 2 Download
  • 24 Crossref
Close layer

Restor Dent Endod : Restorative Dentistry & Endodontics
Close layer
TOP