Skip Navigation
Skip to contents

Restor Dent Endod : Restorative Dentistry & Endodontics

OPEN ACCESS

Search

Page Path
HOME > Search
2 "Nickel-titanium instruments"
Filter
Filter
Article category
Keywords
Publication year
Authors
Research Articles
Effectiveness and safety of rotary and reciprocating kinematics for retreatment of curved root canals: a systematic review of in vitro studies
Lucas Pinho Simões, Alexandre Henrique dos Reis-Prado, Carlos Roberto Emerenciano Bueno, Ana Cecília Diniz Viana, Marco Antônio Húngaro Duarte, Luciano Tavares Angelo Cintra, Cleidiel Aparecido Araújo Lemos, Francine Benetti
Restor Dent Endod 2022;47(2):e22.   Published online April 6, 2022
DOI: https://doi.org/10.5395/rde.2022.47.e22
AbstractAbstract PDFPubReaderePub
Objectives

This systematic review (register-osf.io/wg7ba) compared the efficacy and safety of rotary and reciprocating kinematics in the removal of filling material from curved root canals.

Materials and Methods

Only in vitro studies evaluating both kinematics during retreatment were included. A systematic search (PubMed/MEDLINE, Scopus, and other databases, until January 2021), data extraction, and risk of bias analysis (Joanna Briggs Institute checklist) were performed. Efficacy in filling removal was the primary outcome.

Results

The search resulted in 2,795 studies, of which 15 were included. Efficacy was measured in terms of the remaining filling material and the time required for this. Nine studies evaluated filling material removal, of which 7 found no significant differences between rotary and reciprocating kinematics. Regarding the time for filling removal, 5 studies showed no difference between both kinematics, 2 studies showed faster results with rotary systems, and other 2 showed the opposite. No significant differences were found in apical transportation, centering ability, instrument failure, dentin removed and extruded debris. A low risk of bias was observed.

Conclusions

This review suggests that the choice of rotary or reciprocating kinematics does not influence the efficacy of filling removal from curved root canals. Further studies are needed to compare the kinematics safety in curved root canals.

Citations

Citations to this article as recorded by  
  • Fifteen years of engine‐driven nickel–titanium reciprocating instruments, what do we know so far? An umbrella review
    Felipe Immich, Lucas Peixoto de Araújo, Rafaella Rodrigues da Gama, Wellington Luiz de Oliveira da Rosa, Evandro Piva, Giampiero Rossi‐Fedele
    Australian Endodontic Journal.2024; 50(2): 409.     CrossRef
  • Efficacy of Various Heat-treated Retreatment File Systems on the Apical Deformity and Canal Centering Ability in a Single-rooted Teeth using Nano CT
    Swathi S, Pradeep Solete, Ganesh Jeevanandan, Delphine Priscilla Antony S, Kavalipurapu Venkata Teja, Dona Sanju
    The Open Dentistry Journal.2024;[Epub]     CrossRef
  • Micro-CT evaluation of the removal of root fillings using rotary and reciprocating systems supplemented by XP-Endo Finisher, the Self-Adjusting File, or Er,Cr:YSGG laser
    Gülsen Kiraz, Bulem Üreyen Kaya, Mert Ocak, Muhammet Bora Uzuner, Hakan Hamdi Çelik
    Restorative Dentistry & Endodontics.2023;[Epub]     CrossRef
  • Influence of sodium hypochlorite on cyclic fatigue resistance of nickel–titanium instruments: A systematic review and meta-analysis of in vitro studies
    Alexandre Henrique dos Reis-Prado, Lucas Guimarães Abreu, Lara Cancella de Arantes, Kiani dos Santos de Paula, Sabrina de Castro Oliveira, Juliana Goto, Ana Cecília Diniz Viana, Francine Benetti
    Clinical Oral Investigations.2023; 27(11): 6291.     CrossRef
  • Retreatment of XP-endo Shaper and R-Endo files in curved root canals
    Hayam Y. Hassan, Fahd M. Hadhoud, Ayman Mandorah
    BMC Oral Health.2023;[Epub]     CrossRef
  • Advancing Endodontics through Kinematics
    Shilpa Bhandi, Dario Di Nardo, Francesco Pagnoni, Rosemary Abbagnale
    World Journal of Dentistry.2023; 14(6): 479.     CrossRef
  • 331 View
  • 9 Download
  • 5 Web of Science
  • 6 Crossref
Close layer
Comparison of the shaping ability of novel thermally treated reciprocating instruments
Cangül Keskin, Murat Demiral, Evren Sarıyılmaz
Restor Dent Endod 2018;43(2):e15.   Published online March 3, 2018
DOI: https://doi.org/10.5395/rde.2018.43.e15
AbstractAbstract PDFPubReaderePub
Objectives

The present study aimed to evaluate the shaping ability of 2 thermally treated nickel-titanium reciprocating systems in simulated curved canals.

Materials and Methods

Forty simulated canals were prepared to apical size 25 using Reciproc Blue R25 (VDW) and WaveOne Gold Primary (Dentsply Sirona) instruments. Standard pre- and post-preparation images were taken and superimposed. The removal of resin material was measured at 5 standard points: the canal orifice, halfway between the canal orifice and the beginning of the curve, the beginning of the curve, the apex of the curve, and the end-point of the simulated canal. The data were analysed using the independent sample t-test with a 5% significance threshold.

Results

The canals in which Reciproc Blue R25 was used showed a significantly greater widening than those in which WaveOne Gold was used at 4 of the 5 measurement points (p < 0.05). The Reciproc Blue R25 instrument removed significantly more resin from the inner aspect of the curve at 2 of the 5 points and similar amounts at the remaining 3 points. At the 2 apical points, there was no significant difference between the Reciproc Blue R25 and WaveOne Gold Primary instruments.

Conclusion

Both instruments respected the original canal anatomy; however, WaveOne Gold resulted in a more conservative shape with less transportation.

Citations

Citations to this article as recorded by  
  • Shaping Ability of the Root Canal System Using Reciproc and Reciproc Blue in Preparation of Artificial Canals
    Hawazin Majdi, Khalid Merdad, Tariq Abuhaimed, Lujain Mirdad, Omar Alkhattab, Abdulaziz Bakhsh
    Pesquisa Brasileira em Odontopediatria e Clínica Integrada.2025;[Epub]     CrossRef
  • Comparison of four different file systems in terms of transportation in S-shaped canals and apically extruded debris
    Mustafa Alrahhal, Fatma Tunç
    Journal of Oral Science.2024; 66(4): 226.     CrossRef
  • Assessment of Debris Extrusion in Curved Canals: An In Vitro Analysis of Various Single‐File Endodontic Instrumentation Systems
    Muhammad Zubair Ahmad, Boonlert Kukiattrakoon
    International Journal of Dentistry.2024;[Epub]     CrossRef
  • Shaping ability of rotary and reciprocating single-file systems in combination with and without different glide path techniques in simulated curved canals
    Lu Shi, Yunfei Yang, Jie Wan, Wen Xie, Ruiming Yang, Ying Yao
    Journal of Dental Sciences.2022; 17(4): 1520.     CrossRef
  • An Investigation of the Accuracy and Reproducibility of 3D Printed Transparent Endodontic Blocks
    Martin Smutný, Martin Kopeček, Aleš Bezrouk
    Acta Medica (Hradec Kralove, Czech Republic).2022; 65(2): 59.     CrossRef
  • Shaping Ability of Reciprocating Single-file Systems in Simulated Canals: Reciproc versus Reciproc Blue
    İrem ÇETİNKAYA, Mukadder İnci BAŞER KOLCU
    SDÜ Tıp Fakültesi Dergisi.2021; 28(1): 145.     CrossRef
  • Combination of a new ultrasonic tip with rotary systems for the preparation of flattened root canals
    Karina Ines Medina Carita Tavares, Jáder Camilo Pinto, Airton Oliveira Santos-Junior, Fernanda Ferrari Esteves Torres, Juliane Maria Guerreiro-Tanomaru, Mario Tanomaru-Filho
    Restorative Dentistry & Endodontics.2021;[Epub]     CrossRef
  • Apical extrusion of debris with different rotary and reciprocating single-file endodontic instrumentation systems: a systematic review and meta-analysis protocol
    Muhammad Zubair Ahmad, Durre Sadaf, Marcy McCall MacBain, Ahmed Nabil Mohamed
    BMJ Open.2020; 10(9): e038502.     CrossRef
  • Micro-computed tomographic assessment of the shaping ability of the One Curve, One Shape, and ProTaper Next nickel-titanium rotary systems
    Pelin Tufenkci, Kaan Orhan, Berkan Celikten, Burak Bilecenoglu, Gurkan Gur, Semra Sevimay
    Restorative Dentistry & Endodontics.2020;[Epub]     CrossRef
  • Changes in Geometry and Transportation of Root Canals with Severe Curvature Prepared by Different Heat-treated Nickel-titanium Instruments: A Micro–computed Tomographic Study
    Daniel José Filizola de Oliveira, Graziela Bianchi Leoni, Rafael da Silva Goulart, Manoel Damião de Sousa-Neto, Yara Teresinha Correa Silva Sousa, Ricardo Gariba Silva
    Journal of Endodontics.2019; 45(6): 768.     CrossRef
  • Several factors can affect the root canal transportation of MB2 canals in extracted maxillary first molars
    R. R. Vivan, M. P. Alcalde, E. J de Camargo, V. A. S. Marques, M. V. R. Só, J. A. Duque, M. A. H. Duarte
    International Endodontic Journal.2019; 52(4): 551.     CrossRef
  • Effect of larger apical size on the quality of preparation in curved canals using reciprocating instruments with different heat thermal treatments
    J. A. Duque, R. R. Vivan, M. A. H. Duarte, M. P. Alcalde, V. M. Cruz, M. M. B. Borges, C. M. Bramante
    International Endodontic Journal.2019; 52(11): 1652.     CrossRef
  • 225 View
  • 1 Download
  • 12 Crossref
Close layer

Restor Dent Endod : Restorative Dentistry & Endodontics
Close layer
TOP