Skip Navigation
Skip to contents

Restor Dent Endod : Restorative Dentistry & Endodontics

OPEN ACCESS

Search

Page Path
HOME > Search
2 "NiTi rotary file"
Filter
Filter
Article category
Keywords
Publication year
Authors
Review Article
Mechanical and geometric features of endodontic instruments and its clinical effect
Hyeon-Cheol Kim
J Korean Acad Conserv Dent 2011;36(1):1-11.   Published online January 14, 2011
DOI: https://doi.org/10.5395/JKACD.2011.36.1.1
AbstractAbstract PDFPubReaderePub
Abstract Introduction:

The aim of this paper is to discuss the mechanical and geometric features of Nickel-titanium (NiTi) rotary files and its clinical effects. NiTi rotary files have been introduced to the markets with their own geometries and claims that they have better ability for the root canal shaping than their competitors. The contents of this paper include the (possible) interrelationship between the geometries of NiTi file (eg. tip, taper, helical angle, etc) and clinical performance of the files as follows;

- Fracture modes of NiTi rotary files

- Non-cutting guiding tip and glide path

- Taper and clinical effects

- Cross-sectional area and clinical effects

- Heat treatments and surface characteristics

- Screw-in effect and preservation of root dentin integrity

- Designs for reducing screw-in effect

Conclusions:

Based on the reviewed contents, clinicians may have an advice to use various brands of NiTi rotary instruments regarding their advantages which would fit for clinical situation.

  • 23 View
  • 1 Download
Close layer
Original Article
Effect of surface defects and cross-sectional configuration on the fatigue fracture of NiTi rotary files under cyclic loading
Yu-Mi Shin, Eui-Sung Kim, Kwang-Man Kim, Kee-Yeon Kum
J Korean Acad Conserv Dent 2004;29(3):267-272.   Published online May 31, 2004
DOI: https://doi.org/10.5395/JKACD.2004.29.3.267
AbstractAbstract PDFPubReaderePub

The purpose of this in vitro study was to evaluate the effect of surface defects and cross-sectional configuration of NiTi rotary files on the fatigue life under cyclic loading. Three NiTi rotary files (K3™, ProFile®, and HERO 642®) with #30/.04 taper were evaluated. Each rotary file was divided into 2 subgroups: control (no surface defects) and experimental group (artificial surface defects). A total of six groups of each 10 were tested. The NiTi rotary files were rotated at 300rpm using the apparatus which simulated curved canal (40 degree of curvature) until they fracture. The number of cycles to fracture was calculated and the fractured surfaces were observed with a scanning electron microscope. The data were analyzed statistically. The results showed that experimental groups with surface defects had lower number of cycles to fracture than control group but there was only a statistical significance between control and experimental group in the K3™ (p<0.05). There was no strong correlation between the cross-sectional configuration area and fracture resistance under experimental conditions. Several of fractured files demonstrated characteristic patterns of brittle fracture consistent with the propagation of pre-existing cracks.

This data indicate that surface defects of NiTi rotary files may significantly decrease fatigue life and it may be one possible factor for early fracture of NiTi rotary files in clinical practice.

  • 17 View
  • 0 Download
Close layer

Restor Dent Endod : Restorative Dentistry & Endodontics
Close layer
TOP