Skip Navigation
Skip to contents

Restor Dent Endod : Restorative Dentistry & Endodontics

OPEN ACCESS

Search

Page Path
HOME > Search
4 "Narges Panahandeh"
Filter
Filter
Article category
Keywords
Publication year
Authors
Research Articles
Effects of 3 different light-curing units on the physico-mechanical properties of bleach-shade resin composites
Azin Farzad, Shahin Kasraei, Sahebeh Haghi, Mahboubeh Masoumbeigi, Hassan Torabzadeh, Narges Panahandeh
Restor Dent Endod 2022;47(1):e9.   Published online February 7, 2022
DOI: https://doi.org/10.5395/rde.2022.47.e9
AbstractAbstract PDFPubReaderePub
Objectives

This study investigated the microhardness, flexural strength, and color stability of bleach-shade resin composites cured with 3 different light-curing units.

Materials and Methods

In this in vitro experimental study, 270 samples were fabricated of bleach and A2 shades of 3 commercial resin composites (Point 4, G-aenial Anterior, and Estelite Sigma Quick). Samples (n = 5 for each trial) were cured with Bluephase N, Woodpecker LED.D, and Optilux 501 units and underwent Vickers microhardness and flexural strength tests. The samples were tested after 24 hours of storage in distilled water. Color was assessed using a spectrophotometer immediately after preparation and 24 hours after curing. Data were analyzed using 3-way analysis of variance and the Tukey test (p ≤ 0.001).

Results

Samples cured with Optilux exhibited the highest and those cured with LED.D exhibited the lowest microhardness (p = 0.023). The bleach shade of Point 4 composite cured with Optilux displayed the highest flexural strength, while the same composite and shade cured with Sigma Quick exhibited the lowest (p ≤ 0.001). The color change after 24 hours was greatest for the bleach shade of G-aenial cured with Bluephase N and least for the A2 shade of Sigma Quick cured with Optilux (p ≤ 0.001).

Conclusions

Light curing with polywave light-emitting diode (LED) yielded results between or statistically similar to those of quartz-tungsten-halogen and monowave LED in the microhardness and flexural strength of both A2 and bleach shades of resin composites. However, the brands of light-curing devices showed significant differences in color stability.

  • 23 View
  • 1 Download
  • 2 Web of Science
Close layer
Shade reproduction and the ability of lithium disilicate ceramics to mask dark substrates
Maryam Iravani, Sayna Shamszadeh, Narges Panahandeh, Seyedeh Mahsa Sheikh-Al-Eslamian, Hassan Torabzadeh
Restor Dent Endod 2020;45(3):e41.   Published online July 16, 2020
DOI: https://doi.org/10.5395/rde.2020.45.e41
AbstractAbstract PDFPubReaderePub
Objectives

This study aimed to evaluate the ability of lithium disilicate ceramics to reproduce the A2 shade and to mask A4 substrates.

Materials and Methods

Twenty-four discs (8 mm in diameter, shade A2) of high translucency (groups 1–3) and low translucency (groups 4–6) of IPS e.max ceramic with different thicknesses (0.5, 0.75, and 1 mm) were fabricated as monolithic structures. In addition, discs of medium opacity (group 7–8) with different core/veneer combinations (0.3 mm/0.7 mm and 0.5 mm/0.5 mm) were fabricated as bilayer structures. Specimens were superimposed on an A4 substrate (complex). The color changes of the complex were measured using a spectrophotometer on a black background, and the ΔE values of the complex were compared with either the A4 substrate or the A2 shade tab. One-way analysis of variance, the Tukey honest significant difference test, and the Fisher test were used to analyze the data (p < 0.05).

Results

Significant between-group differences were found for comparisons to both the A4 substrate and the A2 shade (p < 0.05). When compared with the A4 substrate, the ΔE values in all groups were in the non-acceptable range. When compared with the A2 shade, the ΔE values in all groups, except groups 2 and 3, were in the clinically acceptable range.

Conclusions

All translucencies and thicknesses masked the underlying dark substrate. However, the low-translucency IPS e.max Press better reproduced the A2 shade.

  • 20 View
  • 0 Download
Close layer
Bioactivity of endodontic biomaterials on dental pulp stem cells through dentin
Bahar Javid, Narges Panahandeh, Hassan Torabzadeh, Hamid Nazarian, Ardavan Parhizkar, Saeed Asgary
Restor Dent Endod 2020;45(1):e3.   Published online November 4, 2019
DOI: https://doi.org/10.5395/rde.2020.45.e3
AbstractAbstract PDFPubReaderePub
Objectives

This study investigated the indirect effect of calcium-enriched mixture (CEM) cement and mineral trioxide aggregate (MTA), as 2 calcium silicate-based hydraulic cements, on human dental pulp stem cells (hDPSCs) through different dentin thicknesses.

Materials and Methods

Two-chamber setups were designed to simulate indirect pulp capping (IPC). Human molars were sectioned to obtain 0.1-, 0.3-, and 0.5-mm-thick dentin discs, which were placed between the 2 chambers to simulate an IPC procedure. Then, MTA and CEM were applied on one side of the discs, while hDPSCs were cultured on the other side. After 2 weeks of incubation, the cells were removed, and cell proliferation, morphology, and attachment to the discs were evaluated under scanning electron microscopy (SEM). Energy-dispersive X-ray (EDXA) spectroscopy was performed for elemental analysis. Alkaline phosphatase (ALP) activity was assessed quantitatively. The data were analyzed using the Kruskal-Wallis and Mann-Whitney tests.

Results

SEM micrographs revealed elongated cells, collagen fibers, and calcified nucleations in all samples. EDXA verified that the calcified nucleations consisted of calcium phosphate. The largest calcifications were seen in the 0.1-mm-thick dentin subgroups. There was no significant difference in ALP activity across the CEM subgroups; however, ALP activity was significantly lower in the 0.1-mm-thick dentin subgroup than in the other MTA subgroups (p < 0.05).

Conclusions

The employed capping biomaterials exerted biological activity on hDPSCs, as shown by cell proliferation, morphology, and attachment and calcific precipitations, through 0.1- to 0.5-mm-thick layers of dentin. In IPC, the bioactivity of these endodontic biomaterials is probably beneficial.

  • 28 View
  • 0 Download
Close layer
Effect of water storage on flexural strength of silorane and methacrylate-based composite resins
Narges Panahandeh, Hassan Torabzadeh, Hani Naderi, Seyedeh Mahsa Sheikh-Al-Eslamian
Restor Dent Endod 2017;42(4):309-315.   Published online November 6, 2017
DOI: https://doi.org/10.5395/rde.2017.42.4.309
AbstractAbstract PDFPubReaderePub
Objectives

This study assessed the effect of water storage on the flexural strength (FS) of low shrinkage composites.

Materials and Methods

A total of 165 bar-shaped specimens (2 × 2 × 25 mm) were fabricated of 2 low shrinkage composites (Filtek P90 [3M ESPE], GC Kalore [GC International]) and a conventional methacrylate-based composite (Filtek Z250 [3M ESPE]). The specimens were subjected to 3-point bending test at 6 time intervals, namely: immediately after curing, at 24 hours, 1 week, 1 month, 6 months, and 1 year following storage in wet and dry conditions. The FS of the specimens were measured by applying compressive load at a crosshead speed of 1.0 mm/min. Data was analyzed using 3-way analysis of variance (ANOVA) and Tukey's test.

Results

Three-way ANOVA revealed significant interactions between time, type of composite, and storage condition (p = 0.001). Tukey's multiple comparison test revealed significant reductions in FS of all composites after 6 months and 1 year of storage in distilled water compared to dry condition.

Conclusions

Filtek P90 showed the highest and GC Kalore showed the lowest FS after 1 year storage in distilled water. The immediate high strength of Filtek Z250 significantly decreased at 1 year and its final value was lower than that of Filtek P90.

  • 25 View
  • 2 Download
Close layer

Restor Dent Endod : Restorative Dentistry & Endodontics
Close layer
TOP