Skip Navigation
Skip to contents

Restor Dent Endod : Restorative Dentistry & Endodontics

OPEN ACCESS

Search

Page Path
HOME > Search
2 "Jeong-Hye Son"
Filter
Filter
Article category
Keywords
Publication year
Authors
Case Report
Management of white spots: resin infiltration technique and microabrasion
Jeong-Hye Son, Bock Hur, Hyeon-Cheol Kim, Jeong-Kil Park
J Korean Acad Conserv Dent 2011;36(1):66-71.   Published online January 31, 2011
DOI: https://doi.org/10.5395/JKACD.2011.36.1.66
AbstractAbstract PDFPubReaderePub

This case report compared the effectiveness of resin infiltration technique (Icon, DMG) with microabrasion (Opalustre, Ultradent Products, Inc.) in management of white spot lesions. It demonstrates that although neither microabrasion nor resin infiltration technique can remove white spot lesions completely, resin infiltration technique seems to be more effective than microabrasion. Therefore resin infiltration technique can be chosen preferentially for management of white spot lesions and caution should be taken for case selection.

  • 29 View
  • 0 Download
Close layer
Basic Research
The effect of Er,Cr:YSGG irradiation on microtensile bond strength of composite resin restoration
Jeong-Hye Son, Hyeon-Cheol Kim, Bock Hur, Jeong-Kil Park
J Korean Acad Conserv Dent 2010;35(2):134-142.   Published online March 31, 2010
DOI: https://doi.org/10.5395/JKACD.2010.35.2.134
AbstractAbstract PDFPubReaderePub

The purpose of this study was to evaluate the effect of Er,Cr:YSGG laser irradiation with hypersensitivity mode on microtensile bond strength of composite resin. Twenty extracted permanent molars were randomly assigned to six groups, according to the irradiation of Er,Cr:YSGG laser, adhesive system (Optibond FL or Clearfil SE bond) and application time of etchant (15 sec or 20 sec). Then composite resin was build up on each conditioned surface. The restored teeth were stored in distilled water at room temperature for 24 h and twelve specimens for each group were prepared. All specimens were subjected to microtensile bond strength and the fracture modes were evaluated. Also, the prepared dentin surface and laser irradiated dentin surface were examined under SEM.

The results were as follows:

The microtensile bond strength of laser irradiated group was lower than that of no laser irradiated group.

Regardless of laser irradiation, the microtensile bond strength of Optibond FL was higher than that of Clearfil SE bond. And the microtensile bond strength of 20 sec etching group was higher than that of 15 sec etching group when using Optibond FL.

The SEM image of laser irradiated dentin surface showed prominent peritubular dentin, opened dentinal tubules and no smear layer.

  • 20 View
  • 0 Download
Close layer

Restor Dent Endod : Restorative Dentistry & Endodontics
Close layer
TOP