To determine the effect of size and insertion depth of irrigation needle on the amount of apical extruded debris and the amount of penetration depth of sealer using a confocal laser scanning microscope (CLSM).
Twenty maxillary premolars were assigned to 2 groups (
Inserting needles closer to the apex and using needles with wider diameters were associated with significantly more debris extrusion (
Following preparation, inserting narrower needles compatible with the final apical diameter of the prepared root canal at 3 mm short of WL during final irrigation might prevent debris extrusion and improve sealer penetration in the apical third.