Skip Navigation
Skip to contents

Restor Dent Endod : Restorative Dentistry & Endodontics

OPEN ACCESS

Search

Page Path
HOME > Search
4 "Chang-In Seok"
Filter
Filter
Article category
Keywords
Publication year
Authors
Original Articles
Influence of cavity size and restoration methods on the cusp deflection in composite restoration
Mi-Ra Lee, In-Bog Lee, Chang-In Seok, Sang-Tag Lee, Chung-Moon Um
J Korean Acad Conserv Dent 2004;29(6):532-540.   Published online November 30, 2004
DOI: https://doi.org/10.5395/JKACD.2004.29.6.532
AbstractAbstract PDFPubReaderePub

The aim of this study was to measure the cusp deflection during composite restoration for MOD cavity in premolar and to examine the influence of cavity dimension, C-factor and restoration method on the cusp deflection.

Thirty extracted maxillary premolar were prepared to four different sizes of MOD cavity and divided into six groups. The width and depth of the cavity were as follows. Group 1; 1.5 × 1 mm, Group 2; 1.5 × 2 mm, Group 3; 3 × 1 mm, and Group 4-6; 3 × 2 mm respectively. Group 1-4 were restored using bulk filling method with Z-250 composite. However, Group 5 was restored incrementally, and Group 6 was restored with an indirect resin inlay.

The cusp deflection was recorded at the buccal and lingual cusp tips using LVDT probe for 10,000 seconds. The measured cusp deflections were compared between groups, and the relationship between the cube of the length of cavity wall/the cube of the thickness of cavity wall (L3 / T3), C-factor and cusp deflection or %flexure (100 × cuspal deflection / cavity width) was analyzed.

The cusp deflection of Group 1-4 were 12.1 µm, 17.2 µm, 16.2 µm and 26.4 µm respectively. The C-factor was related to the %flexure rather than the cusp deflection. There was a strong positive correlationship between the L3 / T3 and the cusp deflection. The cusp deflection of Group 5 and 6 were 17.4 µm and 17.9 µm respectively, which are much lower value than that of Group 4.

  • 25 View
  • 0 Download
Close layer
The polymerization rate and the degree of conversion of composite resins by different light sources
Joo-Hee Ryoo, In-Bog Lee, Hyun-Mee Yoo, Mi-Ja Kim, Chang-In Seok, Hyuk-Choon Kwon
J Korean Acad Conserv Dent 2004;29(4):386-398.   Published online July 31, 2004
DOI: https://doi.org/10.5395/JKACD.2004.29.4.386
AbstractAbstract PDFPubReaderePub
Objectives

The purpose of this study was to observe the reaction kinetics and the degree of polymerization of composite resins when cured by different light sources and to evaluate the effectiveness of the blue Light Emitting Diode Light Curing Units (LED LCUs) compared with conventional halogen LCUs.

Materials and Methods

First, thermal analysis was performed by a differential scanning calorimeter (DSC). The LED LCU (Elipar Freelight, 320 mW/cm2) and the conventional halogen LCU (XL3000, 400 mW/cm2) were used in this study for curing three composite resins (SureFil, Z-250 and AEliteFLO). Second, the degree of conversion was obtained in the composite resins cured according to the above curing mode with a FTIR. Third, the measurements of depth of cure were carried out in accordance with ISO 4049 standards. Statistical analysis was performed by two-way ANOVA test at 95% levels of confidence and Duncan's procedure for multiple comparisons.

Results

The heat of cure was not statistically different among the LCUs (p > 0.05). The composites cured by the LED (Exp) LCUs were statistically more slowly polymerized than by the halogen LCU and the LED (Std) LCU (p < 0.05). The composite resin groups cured by the LED (Exp) LCUs had significantly greater degree of conversion value than by the halogen LCU and the LED (Std) LCU (p = 0.0002). The composite resin groups cured by the LED (Std) LCUs showed significantly greater depth of cure value than by the halogen LCU and the LED (Exp) LCU (p < 0.05).

  • 20 View
  • 0 Download
Close layer
Evaluation of canal preparation with Ni-Ti rotary files by micro computed tomography
Jeong-Ho Lee, Mi-Ja Kim, Chang-In Seok, Woo-Cheol Lee, Seung-Ho Baek
J Korean Acad Conserv Dent 2004;29(4):378-385.   Published online July 31, 2004
DOI: https://doi.org/10.5395/JKACD.2004.29.4.378
AbstractAbstract PDFPubReaderePub

The purpose of this study was to compare the effects of preparation with GT files and profiles .04 in shaping of root canals and reconstruct the three-dimensional root canal system using micro computed tomography.

40 canals of the extracted human mandibular molars were used, and randomly distributed into two experimental groups. In group 1, canals were prepared by GT files. In group 2, Profiles .04. were used. Apical preparation size was #30.

For each tooth pre and post operative cross-sectional images were obtained by the micro CT at 50 micron intervals. Pre and post operative cross-sectional images of 1, 2, 3, 5, and 8mm from the apex were compared. For each section, canal area and centering ratio were determined. For each tooth pre- and post-operative root canal volume from the furcation to the apex of the roots was calculated by three-dimensional image software. Following results were obtained:

1. At 8mm from the apex, area of dentin removed by GT rotary file was significantly larger than that by Profile .04. And at the other levels there was not a significant difference.

2. There was a trend for GT rotary file to remain more centered in the canals than Profile .04 at all levels. But at 3mm level, there was a statistically significant difference.

3. In root canal volume increments after instrumentation, there was no significant difference between two groups.

  • 20 View
  • 0 Download
Close layer
Dentin bond strength of bonding agents cured with Light Emitting Diode
Sun-Young Kim, In-Bog Lee, Byeong-Hoon Cho, Ho-Hyun Son, Mi-Ja Kim, Chang-In Seok, Chung-Moon Um
J Korean Acad Conserv Dent 2004;29(6):504-514.   Published online January 14, 2004
DOI: https://doi.org/10.5395/JKACD.2004.29.6.504
AbstractAbstract PDFPubReaderePub
ABSTRACT

This study compared the dentin shear bond strengths of currently used dentin bonding agents that were irradiated with an LED (Elipar FreeLight, 3M-ESPE) and a halogen light (VIP, BISCO). The optical characteristics of two light curing units were evaluated. Extracted human third molars were prepared to expose the occlusal dentin and the bonding procedures were performed under the irradiation with each light curing unit. The dentin bonding agents used in this study were Scotchbond Multipurpose (3M ESPE), Single Bond (3M ESPE), One-Step (Bisco), Clearfil SE bond (Kuraray), and Adper Prompt (3M ESPE). The shear test was performed by employing the design of a chisel-on-iris supported with a Teflon wall. The fractured dentin surface was observed with SEM to determine the failure mode.

The spectral appearance of the LED light curing unit was different from that of the halogen light curing unit in terms of maximum peak and distribution. The LED LCU (maximum peak in 465 ㎚) shows a narrower spectral distribution than the halogen LCU (maximum peak in 487 ㎚). With the exception of the Clearfil SE bond (P < 0.05), each 4 dentin bonding agents showed no significant difference between the halogen light-cured group and the LED light-cured group in the mean shear bond strength (P > 0.05).

The results can be explained by the strong correlation between the absorption spectrum of cam-phoroquinone and the narrow emission spectrum of LED.

  • 20 View
  • 0 Download
Close layer

Restor Dent Endod : Restorative Dentistry & Endodontics
Close layer
TOP