Skip Navigation
Skip to contents

Restor Dent Endod : Restorative Dentistry & Endodontics

OPEN ACCESS

Author index

Page Path
HOME > Browse articles > Author index
Search
Seyedeh Mahsa Sheikh-Al-Eslamian 2 Articles
Shade reproduction and the ability of lithium disilicate ceramics to mask dark substrates
Maryam Iravani, Sayna Shamszadeh, Narges Panahandeh, Seyedeh Mahsa Sheikh-Al-Eslamian, Hassan Torabzadeh
Restor Dent Endod 2020;45(3):e41.   Published online July 16, 2020
DOI: https://doi.org/10.5395/rde.2020.45.e41
AbstractAbstract PDFPubReaderePub
Objectives

This study aimed to evaluate the ability of lithium disilicate ceramics to reproduce the A2 shade and to mask A4 substrates.

Materials and Methods

Twenty-four discs (8 mm in diameter, shade A2) of high translucency (groups 1–3) and low translucency (groups 4–6) of IPS e.max ceramic with different thicknesses (0.5, 0.75, and 1 mm) were fabricated as monolithic structures. In addition, discs of medium opacity (group 7–8) with different core/veneer combinations (0.3 mm/0.7 mm and 0.5 mm/0.5 mm) were fabricated as bilayer structures. Specimens were superimposed on an A4 substrate (complex). The color changes of the complex were measured using a spectrophotometer on a black background, and the ΔE values of the complex were compared with either the A4 substrate or the A2 shade tab. One-way analysis of variance, the Tukey honest significant difference test, and the Fisher test were used to analyze the data (p < 0.05).

Results

Significant between-group differences were found for comparisons to both the A4 substrate and the A2 shade (p < 0.05). When compared with the A4 substrate, the ΔE values in all groups were in the non-acceptable range. When compared with the A2 shade, the ΔE values in all groups, except groups 2 and 3, were in the clinically acceptable range.

Conclusions

All translucencies and thicknesses masked the underlying dark substrate. However, the low-translucency IPS e.max Press better reproduced the A2 shade.

  • 13 View
  • 0 Download
Close layer
Effect of water storage on flexural strength of silorane and methacrylate-based composite resins
Narges Panahandeh, Hassan Torabzadeh, Hani Naderi, Seyedeh Mahsa Sheikh-Al-Eslamian
Restor Dent Endod 2017;42(4):309-315.   Published online November 6, 2017
DOI: https://doi.org/10.5395/rde.2017.42.4.309
AbstractAbstract PDFPubReaderePub
Objectives

This study assessed the effect of water storage on the flexural strength (FS) of low shrinkage composites.

Materials and Methods

A total of 165 bar-shaped specimens (2 × 2 × 25 mm) were fabricated of 2 low shrinkage composites (Filtek P90 [3M ESPE], GC Kalore [GC International]) and a conventional methacrylate-based composite (Filtek Z250 [3M ESPE]). The specimens were subjected to 3-point bending test at 6 time intervals, namely: immediately after curing, at 24 hours, 1 week, 1 month, 6 months, and 1 year following storage in wet and dry conditions. The FS of the specimens were measured by applying compressive load at a crosshead speed of 1.0 mm/min. Data was analyzed using 3-way analysis of variance (ANOVA) and Tukey's test.

Results

Three-way ANOVA revealed significant interactions between time, type of composite, and storage condition (p = 0.001). Tukey's multiple comparison test revealed significant reductions in FS of all composites after 6 months and 1 year of storage in distilled water compared to dry condition.

Conclusions

Filtek P90 showed the highest and GC Kalore showed the lowest FS after 1 year storage in distilled water. The immediate high strength of Filtek Z250 significantly decreased at 1 year and its final value was lower than that of Filtek P90.

  • 20 View
  • 2 Download
Close layer

Restor Dent Endod : Restorative Dentistry & Endodontics
Close layer
TOP