Skip Navigation
Skip to contents

Restor Dent Endod : Restorative Dentistry & Endodontics

OPEN ACCESS

Author index

Page Path
HOME > Browse articles > Author index
Search
Hyeong-Soon Shin 1 Article
Accuracy of Root ZX in teeth with simulated root perforation in the presence of gel or liquid type endodontic irrigant
Hyeong-Soon Shin, Won-Kyung Yang, Mi-Ri Kim, Hyun-Jung Ko, Kyung-Mo Cho, Se-Hee Park, Jin-Woo Kim
Restor Dent Endod 2012;37(3):149-154.   Published online August 29, 2012
DOI: https://doi.org/10.5395/rde.2012.37.3.149
AbstractAbstract PDFPubReaderePub
Objectives

To evaluate the accuracy of the Root ZX in teeth with simulated root perforation in the presence of gel or liquid type endodontic irrigants, such as saline, 5.25% sodium hypochlorite (NaOCl), 2% chlorhexidine liquid, 2% chlorhexidine gel, and RC-Prep, and also to determine the electrical conductivities of these endodontic irrigants.

Materials and Methods

A root perforation was simulated on twenty freshly extracted teeth by means of a small perforation made on the proximal surface of the root at 4 mm from the anatomic apex. Root ZX was used to locate root perforation and measure the electronic working lengths. The results obtained were compared with the actual working length (AWL) and the actual location of perforations (AP), allowing tolerances of 0.5 or 1.0 mm. Measurements within these limits were considered as acceptable. Chi-square test or the Fisher's exact test was used to evaluate significance. Electrical conductivities of each irrigant were also measured with an electrical conductivity tester.

Results

The accuracies of the Root ZX in perforated teeth were significantly different between liquid types (saline, NaOCl) and gel types (chlorhexidine gel, RC-Prep). The accuracies of electronic working lengths in perforated teeth were higher in gel types than in liquid types. The accuracy in locating root perforation was higher in liquid types than gel types. 5.25% NaOCl had the highest electrical conductivity, whereas 2% chlorhexidine gel and RC-Prep gel had the lowest electrical conductivities among the five irrigants.

Conclusions

Different canal irrigants with different electrical conductivities may affect the accuracy of the Root ZX in perforated teeth.

Citations

Citations to this article as recorded by  
  • Effect of Different Electroconductive Root Canal Irrigations on the Accuracy of Different Apex Locators: An In Vitro Comparative Study
    Eman M. Yahya, Ashraf S. Alchalabi, Emad Farhan Alkhalidi
    Journal of International Society of Preventive and Community Dentistry.2024; 14(3): 211.     CrossRef
  • The precision of radiographic and electronic working length estimation methods in endodontics: A systematic review of clinical studies
    Anithakumari Rangappa, Buvaneshwari Arul, Jayalakshmi Somasundaram, Velmurugan Natanasabapathy
    Endodontology.2024;[Epub]     CrossRef
  • Comparative evaluation of the accuracy of electronic apex locators and cone-beam computed tomography in detection of root canal perforation and working length during endodontic retreatment
    Simay Koç, Hatice Harorlı, Alper Kuştarcı
    BMC Oral Health.2024;[Epub]     CrossRef
  • Comparative Accuracy and Reliability of Three Electronic Apex Locators in Determining the Apical Constriction of Molar Canals: A Micro-CT Evaluation
    Reem M. Barakat, Rahaf A. Almohareb, Arwa O. Alharbi, Asma Alhazmi, Reem Alomar
    Journal of Clinical Medicine.2024; 13(17): 5199.     CrossRef
  • Accuracy of the integrated electronic apex locator in locating simulated perforation under various irrigating solutions in an in vitro study
    Chintan Joshi, Surabhi Joshi, Urooj Desai, Sweety Thumar, Aashray Patel, Ankita Khunt
    Brazilian Journal of Oral Sciences.2024; 23: e241118.     CrossRef
  • The Accuracy of Different Apex Locator Systems in Detecting Root Perforations in the Presence of Different Irrigation Solutions
    Oğuz Burhan Çetinkaya, Emre Çulha, Uğur Aydın
    European Journal of Therapeutics.2023; 30(1): 39.     CrossRef
  • In Vitro Comparison of the Accuracy of Cone-Beam Computed Tomography Scanning and Electronic Apex Locators in Detection of Simulated Root Perforations in Different Localizations
    Hatice Harorlı, Simay Koç, Alper Kuştarcı
    Journal of Endodontics.2023; 49(12): 1676.     CrossRef
  • Accuracy of different electronic apex locators in determination of minimum Root perforation diameter
    Simay Koç, Alper Kuştarcı, Kürşat Er
    Australian Endodontic Journal.2023; 49(S1): 179.     CrossRef
  • The influence of MTAD and QMix on the accuracy of electronic apex locator in locating simulated perforations
    A Dumani, AA Ates, CS Ucan, S Yilmaz, I Unal, O Yoldas
    Nigerian Journal of Clinical Practice.2022; 25(3): 281.     CrossRef
  • Synthesis and evaluation of grafted xanthan gum as a drug carrier in developing lornoxicam gel formulations
    SandipAshok Murtale, PrakashS Goudanavar, NRaghavendra Naveen, WalaaF Alsanie, Majid Alhomrani, AbdulhakeemS Alamri, SyedMohammed Basheeruddin Asdaq, MdKhalid Anwer, Nagaraja Sreeharsha, MazenAl Gharsan, Santosh Fattepur
    Pharmacognosy Magazine.2022;[Epub]     CrossRef
  • KOMBİNE İRRİGASYON SOLÜSYONLARININ ELEKTRİKSEL İLETKENLİĞİNİN KARŞILAŞTIRILMASI
    Ayşin DUMANİ, Şehnaz YILMAZ, Oğuz YOLDAŞ, Güray KILINÇÇEKER
    Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi.2022; : 1.     CrossRef
  • Accuracy of electronic apex locator in the presence of different irrigating solutions
    Padmanabh Jha, Vineeta Nikhil, Shalya Raj, Rohit Ravinder, Preeti Mishra
    Endodontology.2021; 33(4): 232.     CrossRef
  • Comparative Evaluation of Accuracy of Different Apex Locators: Propex IQ, Raypex 6, Root ZX, and Apex ID with CBCT and Periapical Radiograph—In Vitro Study
    Okba Mahmoud, Mawada Hassan Awad Abdelmagied, Ahmad Hisham Dandashi, Bakr Nssaief Jasim, Hussam Alddin Tawfik Kayali, Saaid Al Shehadat, Luca Testarelli
    International Journal of Dentistry.2021; 2021: 1.     CrossRef
  • Evaluation of Temperature Increase From Joule Heat in Numerical Tooth Model by Applying 500 kHz Current for Apical Periodontitis Treatment—Effect of Applied Voltage and Tooth Conductivity
    Hiroo Tarao, Masatake Akutagawa, Takahiro Emoto, Amane Takei, Hiromichi Yumoto, Toshihiko Tominaga, Toshitaka Ikehara, Yosuke Kinouchi
    Bioelectromagnetics.2021; 42(3): 224.     CrossRef
  • Confort visual en oficinas, factor temporal en la evaluación de deslumbramiento
    J. Yamin, A. Pattini, E. Colombo
    Informes de la Construcción.2020; 72(557): e329.     CrossRef
  • The influence of two forms of chlorhexidine on the accuracy of contemporary electronic apex locators
    Ewa Marek, Ryta Łagocka, Katarzyna Kot, Krzysztof Woźniak, Mariusz Lipski
    BMC Oral Health.2020;[Epub]     CrossRef
  • Efficiency of an integrated apex locator in determining working length in various irrigating solutions: An in vivo study
    RakeshReddy Chukka, MalatiDevi Bellam, NarenderReddy Marukala, Sainath Dinapadu, NareshKumar Konda, Jithender Nagilla
    Journal of Pharmacy And Bioallied Sciences.2020; 12(5): 410.     CrossRef
  • Accuracy of two electronic apex locators in locating root perforations in curved canals in dry and wet conditions: A comparative in vitro study
    MonishaParshotam Khatri, SheetalB Ghivari, Madhu Pujar, Reshma Faras, Pallavi Gopeshetti, Amulya Vanti
    Dental Research Journal.2019; 16(6): 407.     CrossRef
  • Consistency of electronic measurements of endodontic working length when using multiple devices from the same manufacturer—an in vitro study
    Franziska Haupt, M Hülsmann
    Clinical Oral Investigations.2018; 22(9): 3107.     CrossRef
  • The Influence of Various Irrigants on the Accuracy of 2 Electronic Apex Locators in Locating Simulated Root Perforations
    Demet Altunbaş, Alper Kuştarcı, Mustafa Toyoğlu
    Journal of Endodontics.2017; 43(3): 439.     CrossRef
  • Accuracy and Repeatability of 3 Apex Locators in Locating Root Canal Perforations: An Ex Vivo Study
    Fábio Luiz Cunha D'Assunção, Julio Cézar Nascimento Sousa, Kayo César Amaro Felinto, Thiago Clístines de Medeiros, Diego Tavares Leite, Raissa Bezerra de Lucena, Joab de Oliveira Lima
    Journal of Endodontics.2014; 40(8): 1241.     CrossRef
  • 207 View
  • 3 Download
  • 21 Crossref
Close layer

Restor Dent Endod : Restorative Dentistry & Endodontics
Close layer
TOP