Skip Navigation
Skip to contents

Restor Dent Endod : Restorative Dentistry & Endodontics

OPEN ACCESS

Author index

Page Path
HOME > Browse articles > Author index
Search
Hadeer Mostafa El Feky 1 Article
Cyclic fatigue resistance of M-Pro and RaCe Ni-Ti rotary endodontic instruments in artificial curved canals: a comparative in vitro study
Hadeer Mostafa El Feky, Khalid Mohammed Ezzat, Marwa Mahmoud Ali Bedier
Restor Dent Endod 2019;44(4):e44.   Published online November 7, 2019
DOI: https://doi.org/10.5395/rde.2019.44.e44
AbstractAbstract PDFPubReaderePub
Objectives

To compare the flexural cyclic fatigue resistance and the length of the fractured segments (FLs) of recently introduced M-Pro rotary files with that of RaCe rotary files in curved canals and to evaluate the fracture surface by scanning electron microscopy (SEM).

Materials and Methods

Thirty-six endodontic files with the same tip size and taper (size 25, 0.06 taper) were used. The samples were classified into 2 groups (n = 18): the M-Pro group (M-Pro IMD) and the RaCe group (FKG). A custom-made simulated canal model was fabricated to evaluate the total number of cycles to failure and the FL. SEM was used to examine the fracture surfaces of the fragmented segments. The data were statistically analyzed and comparisons between the 2 groups for normally distributed numerical variables were carried out using the independent Student's t-test. A p value less than 0.05 was considered to indicate statistical significance.

Results

The M-Pro group showed significantly higher resistance to flexural cyclic fatigue than the RaCe group (p < 0.05), but there was no significant difference in the FLs between the 2 groups (p ≥ 0.05).

Conclusions

Thermal treatment of nickel-titanium instruments can improve the flexural cyclic fatigue resistance of rotary endodontic files, and the M-Pro rotary system seems to be a promising rotary endodontic file.

Citations

Citations to this article as recorded by  
  • Evaluatation of two nickle-titanium systems’ (Neolix and X Pro Gold) resistance to fracture after immersion in sodium hypochlorite.
    Solmaz Araghi, Abbas Delvarani, Faeze dehghan, Parisa Kaghazloo
    journal of research in dental sciences.2024; 21(1): 17.     CrossRef
  • Endodontic Ni–Ti Rotary Instruments for Glide-path, Are They Still Necessary and How to Think about the Ideal Instrument?
    Shilpa Bhandi, Rodolfo Reda, Luca Testarelli, Elisa Maccari
    The Journal of Contemporary Dental Practice.2024; 25(6): 505.     CrossRef
  • Comparative evaluation of cyclic fatigue resistance of thermomechanically treated NiTi rotary instruments in simulated curved canals with two different radii of curvature: An in vitro Study
    Tahira Hamid, Azhar Malik, Ajay Kumar, Shamim Anjum
    Journal of Conservative Dentistry and Endodontics.2024; 27(4): 393.     CrossRef
  • The Effect of Canal Curvature and Different Manufacturing Processes of Five Different NiTi Rotary Files on Cyclic Fatigue Resistance
    Panupat Phumpatrakom, Awiruth Klaisiri, Sukitti Techapatiphandee, Thippawan Saekow, Panuroot Aguilar
    European Journal of General Dentistry.2024;[Epub]     CrossRef
  • New heat-treated vs electropolished nickel-titanium instruments used in root canal treatment: Influence of autoclave sterilization on surface roughness
    Rahaf A. Almohareb, Reem Barakat, Fatimah Albohairy, Hannes C. Schniepp
    PLOS ONE.2022; 17(3): e0265226.     CrossRef
  • The Effect of Taper and Apical Diameter on the Cyclic Fatigue Resistance of Rotary Endodontic Files Using an Experimental Electronic Device
    Vicente Faus-Llácer, Nirmine Hamoud Kharrat, Celia Ruiz-Sánchez, Ignacio Faus-Matoses, Álvaro Zubizarreta-Macho, Vicente Faus-Matoses
    Applied Sciences.2021; 11(2): 863.     CrossRef
  • 176 View
  • 3 Download
  • 6 Crossref
Close layer

Restor Dent Endod : Restorative Dentistry & Endodontics
Close layer
TOP