Color stability and solubility of Biodentine and NeoPutty in contact with different irrigation solutions
-
Sıla Nur Usta, Cangül Keskin
-
Restor Dent Endod 2024;49(3):e25. Published online June 19, 2024
-
DOI: https://doi.org/10.5395/rde.2024.49.e25
-
-
Abstract
PDFPubReaderePub
- Objectives
This study aimed to evaluate the color stability and solubility of Biodentine and NeoPutty in contact with different irrigation solutions. Materials and MethodsBiodentine and NeoPutty were set in cylindrical molds with 7 mm diameter and 1.5 mm high and immersed in distilled water, 17% ethylenediaminetetraacetic acid (EDTA), 2% chlorhexidine (CHX), 9% 1-hydroxyethylidene 1,1-diphosphonate (HEDP), and 5% sodium hypochlorite (NaOCl) solutions for 24 hours. The color change was measured with a spectrophotometer. The solubility values were calculated as the mass loss was expressed as a percentage of the original mass using an analytical balance with 10−4 g accuracy. Data were analyzed with Kruskal-Wallis followed by Mann-Whitney U tests, and 2-way analysis of variance test followed by Bonferroni corrections for pairwise comparisons for solubility and color stability with a 5% significance threshold, respectively. ResultsBiodentine exhibited higher color changes compared to the NeoPutty contact with all solutions except distilled water (p < 0.05). Both hydraulic cements (HCs) showed higher discoloration values immersion in CHX followed by NaOCl. No statistically significant difference was found between Biodentine and NeoPutty regardless of irrigation solution in terms of solubility (p > 0.05). Solubility values were lower in the distilled water group compared to EDTA and CHX (p < 0.05). ConclusionsTested HCs showed solubility and color changes at various rates. NeoPutty could be an appropriate material in aesthetic areas. The usage of HEDP as an irrigant solution can be considered suitable for various endodontic treatments due to its relatively lower solubility and discoloration values.
-
Comparison of the shaping ability of novel thermally treated reciprocating instruments
-
Cangül Keskin, Murat Demiral, Evren Sarıyılmaz
-
Restor Dent Endod 2018;43(2):e15. Published online March 3, 2018
-
DOI: https://doi.org/10.5395/rde.2018.43.e15
-
-
Abstract
PDFPubReaderePub
- Objectives
The present study aimed to evaluate the shaping ability of 2 thermally treated nickel-titanium reciprocating systems in simulated curved canals. Materials and MethodsForty simulated canals were prepared to apical size 25 using Reciproc Blue R25 (VDW) and WaveOne Gold Primary (Dentsply Sirona) instruments. Standard pre- and post-preparation images were taken and superimposed. The removal of resin material was measured at 5 standard points: the canal orifice, halfway between the canal orifice and the beginning of the curve, the beginning of the curve, the apex of the curve, and the end-point of the simulated canal. The data were analysed using the independent sample t-test with a 5% significance threshold. ResultsThe canals in which Reciproc Blue R25 was used showed a significantly greater widening than those in which WaveOne Gold was used at 4 of the 5 measurement points (p < 0.05). The Reciproc Blue R25 instrument removed significantly more resin from the inner aspect of the curve at 2 of the 5 points and similar amounts at the remaining 3 points. At the 2 apical points, there was no significant difference between the Reciproc Blue R25 and WaveOne Gold Primary instruments. ConclusionBoth instruments respected the original canal anatomy; however, WaveOne Gold resulted in a more conservative shape with less transportation.
|