Do universal adhesives promote bonding to dentin? A systematic review and meta-analysis
Article information
Abstract
Objectives
The aims of this study were to conduct a systematic review of the microtensile bond strength (µTBS) of multi-mode adhesives to dentin and to perform a meta-analysis to assess the significance of differences in the µTBS of one of the most commonly used universal adhesives (Scotchbond Universal, 3M ESPE) depending on whether the etch-and-rinse or self-etch mode was used.
Materials and Methods
An electronic search was performed of MEDLINE/PubMed, ScienceDirect, and EBSCOhost. Laboratory studies that evaluated the µTBS of multi-mode adhesives to dentin using either the etch-and-rinse or self-etch mode were selected. A meta-analysis was conducted of the reviewed studies to quantify the differences in the µTBS of Scotchbond Universal adhesive.
Results
Only 10 studies fulfilled the inclusion criteria for the systematic review. Extensive variation was found in the restorative materials, testing methodologies, and failure mode in the reviewed articles. Furthermore, variation was also observed in the dimensions of the microtensile testing beams. The meta-analysis showed no statistically significant difference between the etch-and-rinse and self-etch modes for Scotchbond Universal adhesive (p > 0.05).
Conclusions
Multi-mode ‘universal’ adhesives can achieve substantial bonding to dentin, regardless of the used modes (either etch-and-rinse or self-etch).
INTRODUCTION
Evidence-based dentistry is an approach to oral health care requiring the judicious integration of systematic assessments of clinically relevant scientific evidence [1]. In routine dental practice, clinicians are committed to providing the best possible dental care for patients. Nowadays, clinical decision-making procedure becomes more sophisticated due to the huge amount of scientific information that is continually published on new therapies, techniques, and restorative materials, which underscores the importance of an evidence-based approach in the field of dentistry. Systematic reviews and meta-analyses are considered to be the highest level of evidence supporting evidence-based decision-making [2].
Adhesive dentistry has advanced rapidly in the past 10 years. Three main strategies are used. The first is based on the total removal of the smear layer, and is referred to as the ‘etch-and-rinse’ approach [3]. Conversely, the second strategy depends on modifying the smear layer, aiming to incorporate it into the adhesive layer; this is referred to as the ‘self-etch’ approach. Additionally, the multi-mode strategy is a combination of the etch-and-rinse and self-etch approaches [4].
In the late 1990s, the chronological ‘generation’-based classification of adhesives was widely used. In this classification, adhesives are classified into 7 generations, according to the chronology of their development. The fourth generation of adhesives was the most famous, to the point that they were referred to as the ‘gold standard’ or ‘classic’ adhesives, in addition to the more descriptive term of ‘three-step etch-and-rinse’ adhesives. Subsequent generations were introduced to simplify the clinical use of adhesives, up to the seventh generation, which comprises ‘all-in-one’ adhesives. Due to the many overlaps and unclear boundaries between the generations, this classification has almost disappeared from regular use, and a new classification was introduced by Van Meerbeek in the early 2000s [4]. According to Van Meerbeek's classification, contemporary dental adhesives are categorized into 3 main groups based on the smear layer treatment strategy: etch-and-rinse, self-etch, and the resin-modified glass-ionomer approach. Then, according to the number of clinical application steps, etch-and-rinse adhesives are further divided into 2 groups: 2- or 3-step etch-and-rinse adhesives. Similarly, self-etch adhesives are further divided into one-step (‘all-in-one’) or two-step self-etch adhesives. Recently, another group, known as universal or multi-mode adhesives, was added to the previous classification [5].
These novel multi-mode adhesives reduce the complexity of clinical application procedures. Adhesives in this category may be used as etch-and-rinse adhesives, self-etch adhesives, or as self-etch adhesives on dentin and etch-and-rinse adhesives on enamel (a technique commonly referred to as ‘selective enamel etching’) [6]. Functional monomers are the principal ingredient of recently developed multi-mode adhesives [78], as they play a major role in chemical adhesion to dentin. Thirty years ago, a dental manufacturer (Kuraray Noritake Dental Inc., Tokyo, Japan) incorporated 10-methacryloyloxydecyl dihydrogen phosphate (10-MDP) as a functional monomer in their dental adhesives. The phosphate group of the MDP interacts with the hydroxyapatite and significantly contributes to the long-term durability of the resin-dentin interface [9].
MDP-based adhesives can chemically bond to the hydroxyapatite crystals of dentin via the electrostatic interactions of ionic bonds formed with the calcium ions of the hydroxyapatite crystals, resulting in an insoluble MDP-calcium salt. Moreover, the phosphate groups in MDP form covalent bonds with the corresponding phosphate groups of hydroxyapatite crystals to form insoluble salts [1011]. The continual deposition of successive coats of these salts on the outer surface of the hydroxyapatite crystal is a process known as ‘nanolayering’ [1213]. Laboratory bond strength tests can provide important insights into the clinical performance of an adhesive under different dislodging forces [14].
The outcomes of previous studies regarding this particular point are unclear and sometimes conflicting. Wagner et al. [15] evaluated the microtensile bond strength of 3 different multi-mode adhesives applied in 2 different modes, self-etch or etch-and-rinse. Their results revealed that the separate etching step did not improve the microtensile bond strength of the multi-mode adhesives when compared to the self-etch application mode. Additionally, the study by Chen et al. [16] showed no significant difference in the bonding of multi-mode adhesive to dentin between the etch-and-rinse and self-etch application modes. Conversely, the study of Muñoz et al. [17] reported that this new category of adhesives exhibited inferior microtensile bond strength values compared to the control ‘conventional’ adhesives.
The key question of this review was “Do multi-mode adhesives provide adequate bonding to dentin when used in either the etch-and-rinse or self-etch mode?” This question cannot be answered in light of the currently available scientific evidence, which is weak. Therefore, this review was designed to assess and analyze the currently available published studies evaluating the bond strength of multi-mode adhesives to dentin. The null hypothesis tested was that there is no difference in the bond strength of multi-mode adhesives to dentin between the etch-and-rinse and self-etch modes.
MATERIALS AND METHODS
Search strategy
In the current review, 3 databases were searched: the National Library of Medicine (MEDLINE/PubMed), ScienceDirect, and EBSCOhost. Studies published after 2005 were included in this review. The keywords used when searching the databases were (‘multi-mode’ or ‘universal’ or ‘multi-purpose’ or ‘bonding strategies’ or ‘multi-mode adhesive’ or ‘universal adhesive’) and (‘microtensile’ or ‘bond strength’) and (‘micromorphology’ or ‘ultramorphology’).
Inclusion/exclusion criteria
Only laboratory studies and manuscripts written in English were included in this structured review. The following studies were excluded: non-English manuscripts, studies published before 2005 (only studies from 2005 until 2016 were included), in vitro studies using animal teeth, review articles, and clinical trials and case reports. Moreover, studies used that multi-mode adhesives for other purposes were excluded. The initial search of the PubMed database identified 542 articles, and was then followed by a subsequent search of the other 2 databases in addition to a manual search.
Eight manuscripts were excluded because they were not written in English, and 181 studies were excluded because they were published before 2005. A further 173 in vitro studies using animal teeth were excluded. Of the remaining 180 manuscripts, 57 clinical trials and 6 review articles were excluded, and 105 other studies were excluded because they utilized universal adhesives for other purposes, such as enamel bonding, bonding to primary teeth, bonding to anterior teeth, orthodontic bracket adhesion, prosthodontics, and endodontics. The detailed study selection procedures are illustrated in a flowchart (Figure 1).
Two authors of this review independently assessed the titles and abstracts of all the studies. Studies were included if they were conducted to evaluate the bonding of multi-mode adhesives to dentin using either the self-etch or etch-and-rinse mode. Studies in which the secondary outcome was the bond strength of multi-mode adhesives to enamel and dentin were also included. The full-text papers were independently assessed in duplicate by the 3 authors. In this review, a study was included if at least 2 of the reviewers (authors) agreed that it was suitable. The reviewed studies were subjected to meta-analysis to quantify the differences in the mean microtensile bond strength of Scotchbond Universal adhesive using Comprehensive Meta-Analysis software, version 2 (Biostat, Englewood, NJ, USA), with 95% confidence intervals.
RESULTS
The current review evaluated 10 studies [15161718192021222324] that were conducted to evaluate the bond strength of 6 different brands of multi-mode adhesives to dentin. Seven of them (70%) evaluated the bond strength of the Scotchbond Universal adhesive (3M ESPE, St. Paul, MN, USA) [15161718192021]. Six studies (60%) evaluated the bond strength of All-Bond Universal (Bisco, Schaumburg, IL, USA) [151617182021], and 4 studies (40%) evaluated the bond strength of G-bond Plus (GC, Tokyo, Japan) [18222324]. The remaining studies evaluated other universal adhesives: Prime & Bond Elect (Dentsply Caulk, Milford, DE, USA; 20%) [1620], Futurabond Universal (Voco, Cuxhaven, Germany; 20%) [1516], Peak Universal Adhesive (Ultradent, South Jordan, UT, USA; 20%) [1721], and Clearfil Universal Bond (Kuraray Noritake Dental Inc.; 10%) [16].
In addition, different types of restorative materials were used, as some studies used the nanocomposite Filtek Z350 (3M ESPE; 30%) [182024], while other studies used Opallis (FGM, Joinville, SC, Brazil; 20%) [1721]. Additionally, microhybrid composites were used in the studies, such as Filtek Z250 (3M ESPE; 10%) [19], Clearfil AP-X (Kuraray Noritake Dental Inc.; 10%) [22], Venus (Heraeus Kulzer, Hanau, Germany; 10%) [23], and TPH Spectra (Dentsply Caulk; 10%) [16]. The other restorative material used was a nanohybrid composite (GrandioSO, Voco; 10%) [15]. The geographical distribution of the reviewed manuscripts was as follows: 4 studies in South America (40%) [17182021], 3 in Europe (30%) [152223], 2 in North America (20%) [1924], and only one study in Asia (10%) [16].
Most of the reviewed articles were recently published. Four studies were published in 2014 (40%) [15182021], 2 were published in 2013 (20%) [1724], 3 were published in 2012 (30%) [192223], and only one study was published in 2015 (10%) [16]. All the reviewed studies (100%) used the microtensile bond strength testing method to determine the bond strength as the primary testing method [15161718192021222324]. However, they showed considerable variation in the secondary testing methods: 4 studies (40%) evaluated interfacial nanoleakage [17182021], 3 studies (30%) evaluated the degree of conversion [171824], and the remaining studies (40%) evaluated the ultra-morphology of the resin-dentin interface using scanning electron microscopy or transmission electron microscopy [15161922]. Additionally, 2 studies (20%) evaluated the enamel microtensile bond strength [2224] and one study (10%) evaluated the dentin microshear bond strength [23]. The summary findings, testing methods, and materials of the included studies are presented in Tables 1 and 2.
The predominant failure mode in the reviewed studies varied widely. The predominant failure mode was adhesive/mixed in 4 studies (40%) [17182124], adhesive in 3 studies (30%) [151720], and mixed in 2 studies (20%) [1516]. Moreover, all the authors clearly stated that the teeth were randomly selected. Furthermore, all the reviewed studies included a control group and were conducted on caries-free molars. The testing cross-head speed of the universal testing machine varied among the studies, as did the microtensile beam dimension. The majority of the studies (80%) used a cross-head speed of 0.5 mm/min [1517181920212224]; however, 2 studies (20%) used a cross-head speed of 1 mm/min [1622]. Six studies (60%) used beam dimensions of 0.8 × 0.8 mm [171819202124], 2 studies (20%) used beam dimensions of 1 × 1 mm [1522], 1 study (10%) [16] used beam dimensions of 0.9 × 0.9 mm, and another study (10%) [23] used sample dimensions of 0.7 × 0.7 mm. The examiner was blinded in only 3 studies (30%) [171821].
Regarding the quality of the studies included, 8 presented a medium risk of bias, while 2 studies showed a low risk of bias. These results are presented in Table 3 according to the parameters considered in the analysis. The studies scored particularly poorly on the following items: description of the coefficient of variation, sample size calculation, and blinding of the examiner.
The outcomes of the microtensile bond strength testing of the multi-mode adhesives used in the reviewed articles are shown in Table 4. After carefully reviewing the selected articles, it was found that 70% evaluated the microtensile bond strength of Scotchbond Universal in both etching modes; therefore, a meta-analysis was conducted. The meta-analysis was performed by combining all the data concerning the microtensile bond strength of Scotchbond Universal in both etching modes with the related number of teeth per group used in the corresponding study (Table 5). The results of the meta-analysis of the microtensile bond strength for Scotchbond Universal were 37.07 ± 2.12 MPa for the etch-and-rinse mode (Figure 2) and 35.81 ± 2.64 MPa for the self-etch mode (Figure 3). According to the statistical model presented by Borenstein et al. [25], there was no significant difference between the etching modes (Table 6).
Assessment of risk of bias
Risk of bias was evaluated according to the following parameters: randomization, blinding of the examiner, the presence of a control group, samples with similar dimensions, cross-head speed, evaluation of the failure mode, analysis by a single observer, description of the coefficient of variation, and sample size calculation. If the authors reported the parameter, the article received a ‘Yes’ for that parameter; if it was not possible to find the information, the article received a ‘No’. Articles that reported one to 3 items were classified as having a high risk of bias, those that reported 4 or 5 items were considered to have a medium risk of bias, and those that reported 6 to 8 items were classified as having a low risk of bias (Table 3).
DISCUSSION
Systematic reviews are a useful tool for clinical practitioners, as they provide accurate evidence-based answers to relevant questions in light of the best available scientific knowledge. Furthermore, systematic reviews can recommend new standardized research protocols and methodologies [2627].
The outcomes of laboratory studies that evaluate the bonding of multi-mode adhesives to dentin are highly dependent on the dentin surface treatment protocol. The majority of new adhesive systems exhibit the versatility of being able to be used in both the etch-and-rinse and self-etch modes; however, the variation in the results may be attributed to the difference in chemical composition among these adhesives. Perdigão et al. [19] reported the presence of MDP in the composition of the multi-mode adhesive Scotchbond Universal (3M ESPE), which can bond chemically to dentin by the formation of stable nanolayer coats around dentinal hydroxyapatites [2829].
Scotchbond Universal also contains polyalkenoic acid copolymer (PAC; Vitrebond copolymer), which in combination with MDP enhances the bonding to dentin in comparison to corresponding PAC-free adhesives. In contrast, Muñoz et al. [17] reported that PAC might compete with the MDP monomer for calcium-binding sites in hydroxyapatite crystals, and due to its high molecular weight, could even prevent monomer approximation during polymerization, harming the chemical bond of MDP to dentin and adversely affecting bond strength. Moreover, it was demonstrated that 2-hydroxyethyl methacrylate competed with MDP by binding to the calcium of hydroxyapatite, decreasing the bond strength to dentin [3031]. The majority of the included studies utilized the Scotchbond Universal (3M ESPE) multi-mode adhesive system. Therefore, it was beneficial to conduct a meta-analysis of these studies. The meta-analysis revealed no significant differences in the microtensile bond strength of Scotchbond multi-mode adhesive between the surface treatment modes.
Theoretically, in the etch-and-rinse mode, the phosphoric acid etching of dentin results in superficial dentin demineralization and total removal of the smear layer, consequently leading to the exposure of dentinal collagen fibrils and promoting the impregnation of monomers [3233]. Many authors have explained the positive results that they obtained from laboratory bond testing within this theoretical framework. However, Pashley et al. [33] showed that the etching procedure reduced the amount of calcium and phosphate ions, as the hydroxyapatite crystals were nearly totally removed after the etching process, which may adversely affect the chemical bonding of MDP to hydroxyapatites.
Recently, it was found that the bonding of multi-mode adhesives to dentin in the etch-and-rinse mode relies on the infiltration of resin into exposed collagen fibril scaffolds, in a process known as ‘micro-mechanical interlocking.’ Furthermore, a true chemical bond was found to have formed due to the presence of functional monomer groups (MDP). This functional group has weak bonding affinity to hydroxyapatite-depleted collagen (etched dentin). This might explain the relatively low bond strength of multi-mode adhesives to dentin when used in the etch-and-rinse mode. Despite the presence of long funnel-shaped resin tags in the etch-and-rinse mode, recent studies showed that these resin tags did not contribute significantly to tensile bond strength [3435].
In contrast, in the self-etch mode, the acidulated monomers simultaneously condition and prime the dentin surface by dissolving the smear layer, with a minimal adverse effect on dentinal calcium and phosphate levels. This might promote chemical interactions of hydroxyapatite crystals with the functional groups of MDP monomers, enhancing the chemical bond between the adhesive and the dentin substrate. However, the amount of resin impregnation during micro-mechanical interlocking in the self-etch mode was affected by the production of a hybrid layer that was thinner than that produced by the etch-and-rinse mode [36]. Moreover, Peumans et al. [37] reported that the thickness of the hybrid layer did not have a major influence on bonding to dentin.
Some variation was observed among the reviewed studies, particularly in the cross-head speed of the universal testing machine and the dimensions of the beams for microtensile bond strength tests. These variations in the methodological setup may have a major influence on the distribution of stresses along the resin/dentin interface. Despite these variations, the loading rate did not significantly influence the bond strength values due to the reduced dimensions of the specimens and the homogeneity of the adhesive interface. Sano et al. [14] reported that the tensile bond strength was inversely related to the surface area of the bonded interface. They attributed this phenomenon to the development of defects and/or stress raisers at the interface [14].
Evaluating the fracture pattern helps to explain the variation in bond strength across different multi-mode adhesive systems. Nevertheless, the results regarding failure patterns in the reviewed studies showed extensive variation, but the adhesive/mixed failure pattern was still the predominant failure mode in the plurality of the studies. Mixed failure was common when microtensile tests were performed under higher testing speeds. In the laboratory studies of Chen et al. [16] and Hanabusa et al. [22], increasing the cross-head speed from 0.5 to 1.0 mm/min resulted in a high frequency of mixed failure. Perdigão et al. [19] and Wagner et al. [15] concluded that adhesive failure patterns were associated with high bond strength values. It is well known that self-etch adhesives exhibit lower bond strength than etch-and-rinse adhesives; however, according the results of this evidence-based review, it seems that the MDP group enhances the bonding of self-etch adhesives to dentin.
Furthermore, most of the studies showed a medium risk of bias. Accordingly, it would be too difficult to control for all the variables that may have influenced the outcomes of the studies.
CONCLUSIONS
Although the reviewed studies showed great variability, sufficient scientific evidence was found to support the hypothesis that the bonding of multi-mode adhesives to dentin does not significantly vary depending on whether the etch-and-rinse or self-etch mode is used.
Notes
Conflict of Interest: No potential conflict of interest relevant to this article was reported.
Author Contributions:
Conceptualization: Hamama HHH, Mahmoud SH.
Data curation: Elkaffas AA, Hamama HHH, Mahmoud SH.
Funding acquisition: Elkaffas AA, Hamama HHH, Mahmoud SH.
Investigation: Elkaffas AA, Hamama HHH, Mahmoud SH.
Methodology: Elkaffas AA, Hamama HHH, Mahmoud SH.
Project administration: Hamama HHH, Mahmoud SH.
Resources: Elkaffas AA, Hamama HHH, Mahmoud SH.
Supervision: Hamama HHH, Mahmoud SH.
Validation: Hamama HHH, Mahmoud SH.
Visualization: Elkaffas AA.
Writing - original draft: Elkaffas AA.
Writing - review & editing: Hamama HHH, Mahmoud SH.
Conference meetings: The preliminary results of this study were presented at the International Association for Dental Research (IADR) general meeting held in South Korea (June 2016).