Comparison of two different methods of detecting residual caries

Comparison of two different methods of detecting residual caries

Article information

Restor Dent Endod. 2017;42(1):48-53
Publication date (electronic) : 2017 January 25
doi : https://doi.org/10.5395/rde.2017.42.1.48
Department of Restorative Dentistry, Hacettepe University, Sıhhıye, Ankara, Turkey.
Correspondence to Uzay Koç Vural, DDS, PhD. Specialist, Department of Restorative Dentistry, Hacettepe University, Sıhhıye, Ankara, Turkey 06100. TEL, +905072122626; FAX, +90312 3051138; uzaykoc@gmail.com; uzaykocvural@gmail.com
Received 2016 June 15; Accepted 2016 November 29.

Abstract

Objectives

The aim of this study was to investigate the ability of the fluorescence-aided caries excavation (FACE) device to detect residual caries by comparing conventional methods in vivo.

Materials and Methods

A total of 301 females and 202 males with carious teeth participated in this study. The cavity preparations were done by grade 4 (Group 1, 154 teeth), grade 5 (Group 2, 176 teeth), and postgraduate (Group 3, 173 teeth) students. After caries excavation using a handpiece and hand instruments, the presence of residual caries was evaluated by 2 investigators who were previously calibrated for visual-tactile assessment with and without magnifying glasses and trained in the use of a FACE device. The tooth number, cavity type, and presence or absence of residual caries were recorded. The data were analyzed using the Chi-square test, the Fisher's Exact test, or the McNemar test as appropriate. Kappa statistics was used for calibration. In all tests, the level of significance was set at p = 0.05.

Results

Almost half of the cavities prepared were Class II (Class I, 20.9%; Class II, 48.9%; Class III, 20.1%; Class IV, 3.4%; Class V, 6.8%). Higher numbers of cavities left with caries were observed in Groups 1 and 2 than in Group 3 for all examination methods. Significant differences were found between visual inspection with or without magnifying glasses and inspection with a FACE device for all groups (p < 0.001). More residual caries were detected through inspection with a FACE device (46.5%) than through either visual inspection (31.8%) or inspection with a magnifying glass (37.6%).

Conclusions

Within the limitations of this study, the FACE device may be an effective method for the detection of residual caries.

Introduction

The widespread concept of minimally invasive dentistry implies that heavily infected and irreversibly denatured dentin should be selectively removed in order to preserve sound or potentially remineralizable tooth tissue as much as possible.12 Pulp exposure can occur due to the over-excavation of carious lesions,3 while residual caries left on the cavity floor may lead to recurrent caries.4 There are still no widely accepted guidelines to determine how much infected dentin can be left on the cavity floor. Therefore, an accurate method should be selected for the identification and removal of infected dentin layers.

A clinically relevant method for assessing the extent of caries excavation should quantify the remaining infected dentin in the cavity after excavation.5 In the past, culturing methods have been used to quantify bacteria in dentin.6 Hardness has been regarded as a principal criterion for the therapeutic endpoint of caries removal using the conventional excavation method for over 60 years.7 Visualtactile inspection is still accepted as the gold standard for residual caries detection.1 The criterion is that ‘the probe should not stick in the dentin and should not give a tugback sensation’.8 However, probing dental hard tissue can cause iatrogenic pulp injuries and false-positive diagnoses.9

A caries-detecting device known as the fluorescence-aided caries excavation (FACE) device has been recently introduced for the visual detection of residual caries to differentiate infected and affected carious dentin. This device, by visualizing the metabolic products of oral microorganisms known as porphyrins,10 can be beneficial to minimize the risk of caries recurrence.11 When an exposed cavity is illuminated with violet light, the dental hard tissues auto-fluoresce (wavelength, 405 nm), because porphyrins reflect red fluorescence, indicating the required caries excavation locations.12 Sound tissues fluoresce green, while carious tissue fluoresces orange-red with the FACE device. Thereby, the FACE device allows the selective removal of infected dentin and the preservation of non-infected dentin.1314

The aim of the present study was to compare the ability of the FACE device and conventional visual-tactile assessment to detect residual caries in the cavities of permanent teeth, which were prepared by students in grades 4 and 5 and postgraduate students. The null hypothesis was that no difference would be present in the incidence of residual caries detected through FACE device inspection and visual-tactile assessment performed with or without magnifying glasses.

Materials and Methods

Patient selection

A total of 503 non-hospitalized volunteer patients (301 females and 202 males) were selected for this study. The procedures and the aims of this study were explained to the patients, and informed consent was obtained before their participation. All procedures were performed in accordance with the Declaration of Helsinki, and ethics committee approval was obtained from the local ethics commission (GO 14/106). Class I, II, III, IV, and V lesions on the permanent dentition were included in the study if they were clinically and radiographically diagnosed free from any pulpitis symptoms. Teeth with pulp exposure were excluded from the study.

Cavity preparation

Cavity preparations were performed by grade 4 (Group 1), grade 5 (Group 2), and postgraduate (Group 3) students. For cavity access, enamel walls were prepared using a high-speed hand piece with diamond burs under continuous water cooling. The superficial, soft, infected dentin was then excavated using sharp spoon excavators and round steel burs of different sizes, without water-cooling.

Visual-tactile assessment with and without magnifying glasses

Two experienced examiners (SG and FYC) assessed all cavities for residual caries using visual-tactile assessment. The examiners made a decision about the presence or absence of residual caries according to the hardness of the lesion area. The teeth were dried briefly using compressed air, isolated with cotton rolls and a saliva ejector, and viewed under standard dental lighting. The cavity preparation was considered as caries-free when a hard cavity floor was felt upon gentle pressure with a dental explorer14 that did not stick in the dentin. The presence of residual caries was recorded.

In the second step, the investigators used magnifying glasses (Keeler, Windsor, UK, ×3 magnification) to assess the cavities, and the recording process was repeated. Disagreements between the examiners were resolved through consensus.

FACE device assessment

Following the visual-tactile assessments, overhead fluorescent lighting was turned off and the light in the room was dimmed. Fluorescent violet light (405 nm, FaceLight, W&H Dentalwerk Bürmoos GmbH, Burmoos, Austria) was generated using a 100 - 130 watt xenon discharge lamp to evaluate caries removal. The operators inspected the cavity through a 500 nm red long-pass glass filter that was compatible with standard corrective goggles to visualize the orange-red fluorescing areas representing the bacteria-infected dentin surfaces (Figure 1). Green fluorescing areas and infected dentin tissue, which appeared dark brown or black, were recorded as caries-free.

Figure 1

View of residual caries (orange color) observed with a fluorescence-aided caries excavation device.

Finally, all remaining carious areas that were diagnosed using these 3 methods were checked again and removed before the final restoration procedure.

Statistical analysis

Kappa statistics was used to evaluate inter-examiner and intra-examiner agreement regarding the clinical calibration for visual-tactile inspection with or without magnifying glasses and the FACE device. The data were analyzed using frequency analysis and the Chi-square test for independent groups. If the expected count in a cell was less than 5, the Fisher's Exact test was used. The McNemar test was used for the comparison of dependent groups (SPSS 20.0, IBM Corp., Armonk, NY, USA). The level of significance was set at α = 0.05. The relationship between the grade of the operators and the assessment methods was assessed. Furthermore, the obtained values for different diagnostic techniques were compared with each other.

Results

A total of 503 teeth (Class I, 105; Class II, 246; Class III, 101; Class IV, 17; Class V, 34 cavities) with carious lesions were prepared by students in grades 4 (Group 1) and 5 (Group 2), and postgraduate students (Group 3). The Chi-square statistical analysis revealed no significant relationship between the grade of students and the prepared cavity type (p > 0.05). Thus, the prevalence and variability of the prepared cavities were sufficient to perform statistical analyses. The distribution of the cavities is shown in Table 1.

Distribution of the cavities according to groups

The inter-examiner reliability between the examiners was over 80%, showing excellent agreement between the examiners (kappa = 0.864). Caries were detected in 160 teeth examined by visual-tactile assessment without magnifying glasses, in 189 teeth by visual-tactile assessment with magnifying glasses, and in 234 teeth using the FACE device. The undergraduate students left higher numbers of cavities with undetected caries than postgraduate students for all assessment methods (Table 2). The relationships between grade and the presence of detected carious lesions using visual inspection with or without magnifying glasses were not found to be significant (p = 0.129 and p = 0.182, respectively). However, a significant relationship was found between grade and the presence of detected carious lesions using the FACE device (p = 0.018, Table 2).

Relationships between the grade of the student operators and assessment methods

Significant differences were found in visual-tactile assessments between Groups 1 and 3 (p < 0.001). The kappa values were substantial and mostly perfect (Table 3). A significant difference between inspection with the FACE device and visual-tactile inspection without magnifying glasses was found for Groups 1 and 2. The kappa values ranged from 0.463 to 0.761 (Table 4). A significant difference between inspection with the FACE device and visual-tactile inspection with magnifying glasses was found in Group 2. The FACE device detected more residual caries than visual-tactile inspection with magnifying glasses. The kappa values varied from moderate to substantial (Table 5).

Relationship between visual inspection without magnifying glasses and with magnifying glasses

Relationship between visual inspection and the use of a FACE device

Relationship between inspection with magnifying glasses and using a FACE device

Discussion

The null hypothesis was rejected, since the comparison of 2 caries-detecting techniques showed that the FACE device helped clinicians leave a cleaner dentin floor than the conventional visual-tactile method performed with or without using magnifying glasses. For the finalization of the caries excavation, visual-tactile assessment with or without magnifying glasses is still used by most clinicians. The problem is always to decide if the therapeutic endpoint has been reached and to distinguish between the dentin that should be removed and the dentin that can be safely left behind. In the ideal caries excavation technique, all carious tissue should be removed selectively, while leaving potentially remineralizable tissue on the cavity floor.13

Current caries excavation techniques are not considered sufficient to remove only the irreversibly destroyed carious tissue.115 Various methods and devices have been introduced for detecting residual caries, including caries detector dyes (CDDs), electronic caries monitors, and laser fluorescence light.1718 However, it has been reported that CDDs were not specific for infected dentin detection and mostly stained the dental-enamel junction or the circumpulpal dentin.19

Conflicting results have been reported for various fluorescence-based devices.3172021 Lennon et al.21 found that the FACE device was more effective in removing infected dentin than conventional excavation and excavation with the aid of CDDs. Lennon et al.22 also investigated the time required to excavate the infected dentin and reported a significantly shorter excavation time with FACE. Zhang et al.16 reported that the caries detection ability of the FACE technique was highly consistent and effective compared to laser-induced fluorescence, chemomechanical excavation, and conventional excavation.

The present study showed that use of the FACE device led to superior results in terms of detecting bacteria remaining in the dentin after excavation. Since more residual caries were detected using the FACE device, it can be asserted that the FACE device can provide a clinical aid in the detection of bacterially infected tissue. The only similar published data, in the study of Peskersoy et al.,23 also demonstrated that the FACE device led to a higher detectability than CDDs in the diagnosis and removal of carious dentin.

The present study also found that visual caries assessment performance was influenced by the use of magnifying glasses. More caries-free cavities were observed when magnifying glasses were used. This may have been due to the detailed visualization of the cavities provided by the magnifying glasses.242526 Zaugg et al.27 reported that dentists using magnifying glasses found more defects than their colleagues using no magnification tools at all. Studies conducted by Narula et al.,24 and Maggio et al.25 showed that magnification loupes significantly enhanced student performance in preclinical dental education and were considered an effective adjunct by the students who used them.

It should be noted that the present study has several limitations related to the FACE device and the study design. As the first step of the assessment process with the FACE device, which is based on light technology, the cavity should be fully opened and accessible. Therefore, unsupported but sound enamel may need to be sacrificed. The size of the light source also restricts the range of application of this technique.16 For example, it was more reliable for the examination of the cavity floor, rather than the cavity walls, due to the field of view. The FACE device works only on cavity locations that can be seen clearly. The lack of standardization of the cavity types and patient-related factors is a limitation related to the study design. Additionally, the caries excavation and examination procedures were more difficult in patients with limited mouth openings.

Conclusions

Although further studies are needed, the promising results of this study suggest that fluorescence-assisted operative techniques may improve the efficiency of caries excavation and the detection of residual caries during cavity preparation.

Notes

Conflict of Interest: No potential conflict of interest relevant to this article was reported.

References

1. de Almeida Neves A, Coutinho E, Cardoso MV, Lambrechts P, Van Meerbeek B. Current concepts and techniques for caries excavation and adhesion to residual dentin. J Adhes Dent 2011;13:7–22. 21403932.
2. Ericson D, Kidd E, McComb D, Mjör I, Noack MJ. Minimally invasive dentistry-concepts and techniques in cariology. Oral Health Prev Dent 2003;1:59–72. 15643750.
3. Krause F, Braun A, Eberhard J, Jepsen S. Laser fluorescence measurements compared to electrical resistance of residual dentine in excavated cavities in vivo. Caries Res 2007;41:135–140. 17284915.
4. Neves AA, Coutinho E, De Munck J, Lambrechts P, Van Meerbeek B. Does DIAGNOdent provide a reliable caries-removal endpoint? J Dent 2011;39:351–360. 21334416.
5. Celiberti P, Francescut P, Lussi A. Performance of four dentine excavation methods in deciduous teeth. Caries Res 2006;40:117–123. 16508268.
6. Banerjee A, Yasseri M, Munson M. A method for the detection and quantification of bacteria in human carious dentine using fluorescent in situ hybridisation. J Dent 2002;30:359–363. 12554119.
7. Ismail AI. Visual and visuo-tactile detection of dental caries. J Dent Res 2004;83(Supplement C):C56–C66. 15286124.
8. Nadanovsky P, Cohen Carneiro F, Souza de Mello F. Removal of caries using only hand instruments: a comparison of mechanical and chemo-mechanical methods. Caries Res 2001;35:384–389. 11641575.
9. Neuhaus KW, Ellwood R, Lussi A, Pitts NB. Traditional lesion detection aids. Monogr Oral Sci 2009;21:42–51. 19494674.
10. Lennon AM, Attin T, Martens S, Buchalla W. Fluorescence-aided caries excavation (FACE), caries detector, and conventional caries excavation in primary teeth. Pediatr Dent 2009;31:316–319. 19722440.
11. Coulthwaite L, Pretty IA, Smith PW, Higham SM, Verran J. The microbiological origin of fluorescence observed in plaque on dentures during QLF analysis. Caries Res 2006;40:112–116. 16508267.
12. Koenig K, Schneckenburger H. Laser-induced autofluorescence for medical diagnosis. J Fluoresc 1994;4:17–40. 24233290.
13. Lai G, Zhu L, Xu X, Kunzelmann KH. An in vitro comparison of fluorescence-aided caries excavation and conventional excavation by microhardness testing. Clin Oral Investig 2014;18:599–605.
14. Lai G, Kaisarly D, Xu X, Kunzelmann KH. MicroCT-based comparison between fluorescence-aided caries Detection of residual caries excavation and conventional excavation. Am J Dent 2014;27:12–16. 24902399.
15. Neves Ade A, Coutinho E, De Munck J, Van Meerbeek B. Caries-removal effectiveness and minimal-invasiveness potential of caries-excavation techniques: a micro-CT investigation. J Dent 2011;39:154–162. 21111770.
16. Zhang X, Tu R, Yin W, Zhou X, Li X, Hu D. Micro-computerized tomography assessment of fluorescence aided caries excavation (FACE) technology: comparison with three other caries removal techniques. Aust Dent J 2013;58:461–467. 24320903.
17. Unlu N, Ermis RB, Sener S, Kucukyilmaz E, Cetin AR. An in vitro comparison of different diagnostic methods in detection of residual dentinal caries. Int J Dent 2010;2010:864935. 20613961.
18. Meller C, Heyduck C, Tranaeus S, Splieth C. A new in vivo method for measuring caries activity using quantitative light-induced fluorescence. Caries Res 2006;40:90–96. 16508264.
19. Ganter P, Al-Ahmad A, Wrbas KT, Hellwig E, Altenburger MJ. The use of computer-assisted FACE for minimal-invasive caries excavation. Clin Oral Investig 2014;18:745–751.
20. Lennon AM, Buchalla W, Switalski L, Stookey GK. Residual caries detection using visible fluorescence. Caries Res 2002;36:315–319. 12399691.
21. Lennon AM, Attin T, Buchalla W. Quantity of remaining bacteria and cavity size after excavation with FACE, caries detector dye and conventional excavation in vitro. Oper Dent 2007;32:236–241. 17555174.
22. Lennon AM, Buchalla W, Rassner B, Becker K, Attin T. Efficiency of 4 caries excavation methods compared. Oper Dent 2006;31:551–555. 17024942.
23. Peskersoy C, Turkun M, Onal B. Comparative clinical evaluation of the efficacy of a new method for caries diagnosis and excavation. J Conserv Dent 2015;18:364–368. 26430298.
24. Narula K, Kundabala M, Shetty N, Shenoy R. Evaluation of tooth preparations for Class II cavities using magnification loupes among dental interns and final year BDS students in preclinical laboratory. J Conserv Dent 2015;18:284–287. 26180411.
25. Maggio MP, Villegas H, Blatz MB. The effect of magnification loupes on the performance of preclinical dental students. Quintessence Int 2011;42:45–55. 21206933.
26. Farook SA, Stokes RJ, Davis AK, Sneddon K, Collyer J. Use of dental loupes among dental trainers and trainees in the UK. J Investig Clin Dent 2013;4:120–123.
27. Zaugg B, Stassinakis A, Hotz P. Influence of magnification tools on the recognition of simulated preparation and filling errors. Schweiz Monatsschr Zahnmed 2004;114:890–896. 15529656.

Article information Continued

Figure 1

View of residual caries (orange color) observed with a fluorescence-aided caries excavation device.

Table 1

Distribution of the cavities according to groups

Cavity type
Group Class I Class II Class III Class IV Class V Total
n % n % n % n % n % n %
1 29 5.8 63 12.5 43 8.5 9 1.8 10 2.0 154 30.6
2 35 7.0 93 18.5 30 6.0 4 0.8 14 2.8 176 35.0
3 41 8.2 90 17.9 28 5.6 4 0.8 10 2.0 173 34.4
Total 105 20.9 246 48.9 101 20.1 17 3.4 34 6.8 503 100.0

Table 2

Relationships between the grade of the student operators and assessment methods

Visual inspection without magnifying glasses Visual inspection with magnifying glasses FACE device
Group Caries-free Caries detected Caries-free Caries detected Caries-free Caries detected
n % n % n % n % n % n %
1 100 64.9 54 35.1 88 57.1 66 42.9 79 51.3 75 48.7
2 115 65.3 61 34.7 110 62.5 66 37.5 83 47.2 93 52.8
3 128 74.0 45 26.0 116 67.1 57 32.9 107 61.8 66 38.2
p 0.129 (df = 2) 0.182 (df = 2) 0.018 (df = 2)

FACE, fluorescence-aided caries excavation.

Table 3

Relationship between visual inspection without magnifying glasses and with magnifying glasses

Visual inspection with magnifying glasses
Group 1 Group 2 Group 3
Caries-free Caries detected Total Caries-free Caries detected Total Caries-free Caries detected Total
n % n % n n % n % n n % n % n
Visual inspection without magnifying glasses Caries-free 87 87.0 13 13.0 100 107 93.0 8 7.0 115 114 89.1 14 10.9 128
Caries detected 1 1.9 53 98.1 54 3 4.9 58 95.1 61 2 4.4 43 95.6 45
Total 88 57.1 66 42.9 154 110 62.5 66 37.5 176 116 67.1 57 32.9 173
p 0.002 (df = 1) 0.227 (df = 1) 0.004 (df = 1)
Kappa and p value 0.810, p < 0.001 0.865, p < 0.001 0.779, p < 0.001

Table 4

Relationship between visual inspection and the use of a FACE device

FACE device
Group 1 Group 2 Group 3
Caries-free Caries detected Total Caries-free Caries detected Total Caries-free Caries detected Total
n % n % n n % n % n n % n % n
Visual inspection without magnifying glasses Caries-free 69 69.0 31 31.0 100 73 63.5 42 36.5 115 102 79.7 26 20.3 128
Caries detected 10 18.5 44 81.5 54 10 16.4 51 83.6 61 5 11.1 40 88.9 45
Total 79 51.3 75 48.7 154 83 47.2 93 52.8 176 107 61.8 66 38.2 173
p 0.001 (df = 1) 0.001 (df = 1) 0.064 (df = 1)
Kappa and p value 0.463, p < 0.001 0.473, p < 0.001 0.761, p < 0.001

FACE, fluorescence-aided caries excavation.

Table 5

Relationship between inspection with magnifying glasses and using a FACE device

FACE device
Group 1 Group 2 Group 3
Caries-free Caries detected Total Caries-free Caries detected Total Caries-free Caries detected Total
n % n % n n % n % n n % n % n
Visual inspection with magnifying glasses Caries-free 67 76.1 21 23.9 88 73 66.4 37 33.6 110 102 87.9 14 12.1 116
Caries detected 12 18.2 54 81.8 66 10 15.2 56 84.8 66 5 8.8 52 91.2 57
Total 79 51.3 75 48.7 154 83 47.2 93 52.8 176 107 61.8 66 38.2 173
p 0.163 (df = 1) 0.001 (df = 1) 0.064 (df = 1)
Kappa and p value 0.570, p < 0.001 0.473, p < 0.001 0.761, p < 0.001

FACE, fluorescence-aided caries excavation.