Effect of resin matrix on degree of conversion and fracture toughness of dental composites

Effect of resin matrix on degree of conversion and fracture toughness of dental composites

Article information

Restor Dent Endod. 2002;27(1):77-86
Publication date (electronic) : 2002 January 31
doi : https://doi.org/10.5395/JKACD.2002.27.1.077
Department of Conservative Dentistry, Graduate School of Dentistry, Kyung Hee University, Korea.

Abstract

Current composites are made with dimethacrylate monomers and silane-treated silica microfillers, either alone or with silane treated glass fillers. The main reasons for clinical failure of dental composites are secondary caries, wear and fracture. Most of practitioner want to get a composite which is more tougher under occlusal stress, less polymerization contraction, and better handling properties in application clinically. The aim of this study was to investigate the influence of resin matrix with various flows on the physical properties such as fracture toughness and degree of conversion of the experimental resins. It was hypothesized that flexible or tough resin composites can be designed by judicious choice of monomer composition.

Various flow resin matrices containing Bis-GMA, UDMA, and TEG-DMA were made by altering the proportion of the monomers. After the unfilled resins were light-cured for different light intensity, the fracture toughness(K1c) was measured according to ASTM standard using the single edge notched geometry, and degree of conversion(DC) was measured by FTIR. And experimental composites were formulated with variations in the proportion of silanated quartz and strontium glass fillers as 60, 75, and 77wt%. Also, the physical properties of composites with various filler contents were evaluated as same manner. All resulting data were compared by ANOVA/Tukeys test at 0.05 level.

The results were as follows;

1. The degree of conversion of high flow resin containing less Bis-GMA was higher than that of low flow unfilled resin.

2. While the degree of conversion of unfilled resin was increased according to light intensity for polymerization, there was no significant increase with moderate and high light intensity. Also, the fracture toughness was not increased by high light intensity.

3. The fracture toughness was high in the low flow unfilled resin containing higher contents of Bis-GMA.

4. There was a significant increase for fracture toughness and a tendency for degree of conversion to be reduced when the content of fillers was increased.

5. In the experimental composites, the flow of resin matrix did not affected on the fracture toughness, even, which was decreased as increase of viscosity.

These results showed that the physical properties of a dental composite could be attributed to the flow of resin matrix with relative content of monomers. Specific combination of resin monomers should be designed to fulfil the needs of specific indication for use.

References

1. Full CA, Hollander WR. The composite resin restoration. A literature review part III. What the future holds. ASDC J Dent Child 1993. 6057–59.
2. Ferracane JL. Using posterior composites appropriately. J Am Dent Assoc 1992. 12353–58.
3. Phillips RW. Skinner's science of dental materials 1973. 7th editionth ed. Philadelphia, PA: WB Saunders Co.;
4. Asmussen E, Peutzfeldt A. Mechanical properties of heat-treated restorative resin for use in the inlay/onlay technique. Scand J Dent Res 1990. 98564–567.
5. Peutzfeldt A, Asmussen E. Influence of aldehydes on selected mechanical properties of resin composites. J Dent Res 1992. 711522–1524.
6. Peutzfeldt A, Asmussen E. In vitro wear, hardness and conversion of diacetyl-containing and propanal-containing resin materials. Dent Mater 1996. 12103–108.
7. Ruyter IE. In : Vanherle , Smith , eds. Monomer systems and polymerization. In posterior composites resin dental restorative materials 1985. Utrecht, The Netherlands: P Szulo Publishing; 109–135.
8. Peutzfeldt A. Resin composites in dentistry: the monomer systems. Eur J Oral Sci 1997. 10597–116.
9. Kaye GWC, Laby TH. Tables of physical and chemical constants and some mathematical functions 1959. 12th editionth ed. London: Longmans, Green & Co.; 37.
10. Asmussen E. Penetration of restorative resins into acid etched enamel (I). Acta Odontol Scand 1977. 35175–182.
11. Ruyter IE, Oysaed H. Composites for use in posterior teeth: Composition and conversion. J Biomed Mater Res 1987. 2111–23.
12. Glenn JF. In : Smith DC, Williams DF, eds. Composition and properties of unfilled and composite resin restorative materials. Biocompatibility of dental materials vol.IIIBoca Raton, FL: CRC Press Inc.; 98–130.
13. Indrani DJ, Cook WD, Televantos F, Tyas MJ, Harcourt JK. Fracture toughness of water- aged resin composite restorative materials. Dent Mater 1995. 11201–207.
14. Olea N, Pulgar R, Perez P, Pea-Serrano F, Rivas A, Novillo-Fertrell A, Pedraza V, Soto A, Sonnenschein C. Estrogenicity of resin-based composites and sealants used in dentistry. Environ Health Perspect 1996. 104298–305.
15. Ruyter IE, Svendsen SA. Remaining methacrylate groups in composite restorative materials. Acta Odontol Scand 1978. 3675–82.
16. Ferracane JL. Elution of leachable components from composites. J Oral Rehabil 1994. 21441–452.
17. Ferracane JL, Greener EH. The effect of resin formulation on the degree of conversion and mechanical properties of dental restorative resins. J Biomed Mater Res 1986. 20121–131.
18. Asmussen E. Restorative resins: hardness and strength vs. quantity of remaining double bonds. Scand J Dent Res 1982. 90484–489.
19. Kelly JR. Perspectives on strength. Dent Mater 1995. 11103–110.
20. Beaumont PWR, Young RJ. Slow crack growth in acrylic bone cement. J Biomed Mater Res 1975. 9423–439.
21. Mecholsky JJ. Fracture mechanics principles. Dent Mater 1995. 11111–112.
22. Griffith AA. The phenomena of rupture and flow in solids. Phil Trans Series A 1920. 221163–198.
23. Hertzberg RW. Deformation and fracture mechanics of engineering materials 1989. New York: John Wiley and Sons; 274–283.
24. Tyas MJ. Correlation between fracture properties and clinical performance of composite resins in class IV cavities. Aust Dent J 1990. 35(1)46–49.
25. Mazer RB, Leinfelder KF, Russell CM. Degradation of microfilled posterior composite. Dent Mater 1992. 8(3)185–189.
26. Knibbs PJ, Smart ER. The clinical performance of a posterior composite resin restorative material. J Oral Rehabil 1992. 19(3)231–237.
27. Stangel I, Barolet RY. Clinical evaluation of two posterior composite resins. J Oral Rehabil 1990. 17(3)257–268.
28. ASTM Standard E 399-83. Standard test method for plane-strain fracture toughness of metallic materials. 1984 Annual book of ASTM standard 1984. Philadelphia: ASTM; 592–622.
29. Ferracane JL, Antonio RC, Matsumoto H. Variables affecting the fracture toughness of dental composites. J Dent Res 1987. 66(6)1140–1145.
30. Ferracane JL. In vitro evaluation of composite resins. Structure-property relationships. Trans Acad Dent Mater 1989. 26–35.
31. Feilzer AJ, Dooren LH, De Gee AJ, Davidson CL. Influence of light intensity on polymerization shrinkage and integrity of restoration-cavity interface. Eur J Oral Sci 1995. 103322–326.
32. Asmussen E, Peutzfeldt A. Influence of UEDMA, Bis-GMA and TEGDMA on selected mechanical properties of experimental resin composites. Dent Mater 1998. 14(1)51–56.
33. Tarumi H, Imazato S, Ehara A, Kato S, Ebi N, Ebisu S. Post-irradiation polymerization of composites containing Bis-GMA and TEGDMA. Dent Mater 1999. 15(4)238–242.
34. Braem M, Ringer W, van Doren V, Lambrechts P, Vanherle G. Mechanical properties and filler fraction of dental composites. Dent Mater 1989. 5346–349.
35. Lloyd CH, Mitchell L. The fracture toughness of tooth coloured restorative materials. J Oral Rehabil 1984. 11257–272.
36. Kim KH, Park JH, Imai Y, Kishi T. Microfracture mechanisms of dental resin composites containing spherically-shaped filler particles. J Dent Res 1994. 73(2)499–504.
37. Ferracane JL, Berge HX. Fracture toughness of experimental dental composites aged in ethanol. J Dent Res 1995. 74(7)1418–1423.
38. Young RJ, Beaumont PWR. Failure of brittle polymers by slow crack growth. Part 2. Failure processes in a silica particle-filled epoxy resin composite. J Mater Sci 1975. 101343–1350.
39. Eliades GC, Vougiouklakis GJ, Caputo AA. Degree of double bond conversion in light-cured composites. Dent Mater 1987. 319–25.
40. Yoshida K, Greener EH. Effects of two amine reducing agents on the degree of conversion and physical properties of an unfilled light-cured resin. Dent Mater 1993. 9(4)246–251.
41. Yoshida K, Greener EH. Effect of photoinitiator on degree of conversion of unfilled light-cured resin. J Dent 1994. 22(5)296–299.
42. Kawaguchi M, Fukushima T, Miyazaki K. The relationship between cure depth and transmission coefficient of visible-light-activated resin composites. J Dent Res 1994. 73(2)516–521.
43. Beatty MW, Swartz ML, Moore BK, Phillips RW, Roberts TA. Effect of crosslinking agent content, monomer functionality, and repeat unit chemistry on properties of unfilled resins. J Biomed Mater Res 1993. 27(3)403–413.
44. Rueggeberg FA, Jordan DM. Effect of light- tip distance on polymerization of resin composite. Int J Prosthodont 1993. 6(4)364–367.
45. Lovell LG, Newman SM, Bowman CN. The effects of light intensity, temperature, and comonomer composition on the polymerization behavior of dimethacrylate dental resins. J Dent Res 1999. 78(8)1469–1476.
46. Davidson CL, Feilzer AJ. Polymerization shrinkage and polymerization shrinkage stress in polymer-based restoratives. J Dent 1997. 25(6)435–440.
47. Choi KK, Condon JR, Ferracane JL. The effects of adhesive thickness on polymerization contraction stress of composite. J Dent Res 2000. 79(3)812–817.
48. Davidson-Kaban SS, Davidson CL, Feilzer AJ, De Gee AJ, Erdilek N. The effect of curing light variations of bulk curing and wall-to-wall quality of two types and various shades of resin composites. Dent Mater 1997. 13344–352.
49. Sakaguchi RL, Berge HX. Reduced light energy density decreased post-gel contraction while maintaining degree of conversion in composites. J Dent 1998. 26695–700.
50. Silikas N, Watts DC. Rheology of urethane dimethacrylate and diluent formulations. Dent Mater 1999. 15(4)257–261.
51. St Germain H, Swartz ML, Phillips RW, Moore BK, Roberts TA. Properties of microfilled composite resins as influenced by filler content. J Dent Res 1985. 64155–160.
52. Ferracane JL, Condon JR, Suh B. Effect of filler on degree of conversion(DC) of resins. J Dent Res (abstract) 1992. 71598.
53. Asmussen E. Clinical relevance of physical, chemical, and bonding properties of composite resins. Oper Dent 1985. 1061–73.
54. Ferracane JL, Mitchem JC, Condon JR, Todd R. Wear and marginal breakdown of composites with various degrees of cure. J Dent Res 1997. 76(8)1508–1516.
55. Jones DW, Rizkalla AS. Characterization of experimental composite biomaterials. J Biomed Mater Res 1996. 3389–100.

Article information Continued

Fig. 1

Fracture toughness of unfilled resins varied with flow of resin matrix.

Fig. 2

Fracture toughness of unfilled resins varied with light intensity for polymerization.

Fig. 3

Fracture toughness of composite resins varied with flow of resin matrix and filler contents.

Fig. 4

Degree of conversion of unfilled resins varied with flow of resin.

Fig. 5

Degree of conversion of unfilled resins varied with light intensity for polymerization.

Fig. 6

Degree of conversion of composite resins varied with flow of resin matrix and filler contents.

Table 1

The composition of the experimental resin and filler

Table 1

Bis-GMA:2,2-bis[4-(2-hydroxy-3-methacryloyloxy)phenyl] propane

UDMA:urethane dimethacrylate

TEGDMA:triethyleneglycol dimethacrylate

CQ:camphoroquinone, initiator

DMAEDA:2-(dimethylamino)ethyl methacrylate, accelerator

BHT:butylated hydroxytoluene, inhibitor

Table 2

Fracture toughness of unfilled resins varied with flow of resin matrix and light intensity for polymerization.

Table 2

Table 3

Fracture toughness of composite resins varied with flow of resin matrix and filler contents.

Table 3

Table 4

Degree of conversion of unfilled resins varied with flow of resin matrix and light intensity for polymerization.

Table 4

Table 5

Degree of conversion of composite resins varied with flow of resin matrix and filler contents

Table 5