Evaluating the reliability and repeatability of the digital color analysis system for dentistry

Evaluating the reliability and repeatability of the digital color analysis system for dentistry

Article information

Restor Dent Endod. 2008;33(4):352-368
Publication date (electronic) : 2008 July 31
doi : https://doi.org/10.5395/JKACD.2008.33.4.352
Department of Conservative Dentistry, School of Dentistry, DSRI, Chonnam National University, Korea.
Corresponding Author: In-Nam Hwang. Department of Conservative Dentistry, School of Dentistry, Chonnam National University 5 Hak-dong, Dong-gu, Gwangju, 501-757, Korea. Tel: 82-62-220-4443, Fax: 82-62-225-8387, hinso@jnu.ac.kr
Received 2008 April 22; Revised 2008 May 26; Accepted 2008 May 29.

Abstract

This study was done to evaluate the reliability of the digital color analysis system (ShadeScan, CYNOVAD, Montreal, Canada) for dentistry.

Sixteen tooth models were made by injecting the A2 shade chemical cured resin for temporary crown into the impression acquired from 16 adults. Surfaces of the model teeth were polished with resin polishing cloth. The window of the ShadeScan handpiece was placed on the labial surface of tooth and tooth images were captured, and each tooth shade was analyzed with the ShadeScan software. Captured images were selected in groups, and compared one another.

Two models were selected to evaluate repeatability of ShadeScan, and shade analysis was performed 10 times for each tooth.

And, to ascertain the color difference of same shade code analyzed by ShadeScan, CIE L*a*b*values of shade guide of Gradia Direct (GC, Tokyo, Japan) were measured on the white and black background using the Spectrolino (GretagMacbeth, USA), and Shade map of each shade guide was captured using the ShadeScan.

There were no teeth that were analyzed as A2 shade and unique shade. And shade mapping analyses of the same tooth revealed similar shade and distribution except incisal third.

Color difference (ΔE*) among the Shade map which analyzed as same shade by ShadeScan were above 3.

Within the limits of this study, digital color analysis instrument for dentistry has relatively high repeatability, but has controversial in accuracy.

References

1. Sproull RC. Color matching in dentistry. Part II: Practical applications of the organization of color. J Prosthet Dent 1973. 29556–566.
2. Paravina RD, Power JM, Fay RM. Color comparison of two shade guides. Int J Prosthodont 2002. 1573–78.
3. Hwang IN, Oh WM. Colorimetric Analysis of Extracted Human Teeth and Five Shade Guides. J Korean Acad Conserv Dent 1997. 22769–781.
4. Preston JD. Current status of shade selection and color matching. Quintessence Int 1985. 1647–58.
5. Grajower R, Revah A, Sorin S. Reflectance spectra of natural and acrylic resin teeth. J Prosthet Dent 1976. 36570–579.
6. Bell AM, Kurzeja R, Gemberg MG. Ceramometal crowns and bridges: focus on failures. Dent Clin North Am 1985. 29763–778.
7. O'Brien WJ, Boenke KM, Groh CL. Coverage errors of two shade guides. Int J Prosthodont 1991. 445–50.
8. Cernavin I. Effect of chlorine-containing disinfecting compounds on shade guides made of acrylic resin. J Prosthet Dent 1996. 75574.
9. Sykora O. Fabrication of a posterior shade guide for removable partial dentures. J Prosthet Dent 1983. 50287–288.
10. Lemire PA, Burk B. Color in dentistry 1975. Hartford, CT: J.M Ney Co.;
11. Grajower R, Revah A, Sorin S. Reflectance spectra of natural and acrylic teeth. J Prosthet Dent 1976. 36570–579.
12. Macentee M, Lakowski R. Instrumental color measurement of vital and extracted teeth. J Oral Rehabil 1981. 8203–208.
13. Goodkind RJ, Schwabacher WB. Use of a fiber-optic colorimeter for in vivo color measurements of 2830 anterior teeth. J Prosthet Dent 1987. 58535–542.
14. Park HK, Jeong JH. A Study on the Color of Korean Natural Teeth. J Korean Acad Prosthodont 1988. 26185–195.
15. Cho KM, Shin DH. Color Analysis of the Natural Teeth with a Modified Intraoral Spectrophotometer. J Korean Acad Conserv Dent 1998. 23223–235.
16. Freedman G. Communicating color. Dent Today 2001. 2078–80.
17. Chu SJ, Tarnow DP. Digital shade analysis and verification: A case report and discussion. Pract Proced Aesthet Dent 2001. 13129–136.
18. Chu SJ. Precision shade technology: Contemporary strategies in shade selection. Pract Proced Aesthet Dent 2002. 1479–83.
19. Paravina RD, Powers JM. Esthetic color training in dentistry 2004. St. Louis, Missouri: Mosby Inc.; 165–174.
20. Clark EB. An analysis of tooth color. J Am Dent Assoc 1931. 182093–2103.
21. Clark EB. Tooth color selection. J Am Dent Assoc 1933. 201065–1073.
22. Miller LL. Shade matching. J Esthet Dent 1993. 5143–153.
23. Miller LL. Organizing color in dentistry. J Am Dent Assoc 1987. 12. Spec No26E–40E.
24. Hayashi T. Medical color standard. V. Tooth crown 1967. Tokyo: Japan Color Research Institute;
25. Goodkind RJ, Loupe MJ. Teaching of color in predoctoral and postdoctoral dental education in 1988. J Prosthet Dent 1992. 67713–717.
26. O'Brien WJ, Groh CL, Boenke KM. A one-dimensional color order system for dental shade guides. Dent Mater 1989. 5371–374.
27. Seghi RR, Hewlett ER, Kim J. Visual and instrumental colorimetric assessments of small color differences on translucent dental porcelain. J Dent Res 1989. 681760–1764.
28. Gross MD, Moser JB. A colorimetric study of coffee and tee staining of four composite resins. J Oral Rehabil 1977. 4311–322.
29. Hwang IN, Lee KW. Translucency of Light Cured Composite Resins Depends on Thickness & its Influence on Color of Restorations. J Korean Acad Conserv Dent 1999. 24604–613.
30. Johnston WM, Kao EC. Assessment of appearance match by visual observation and clinical colorimeter. J Dent Res 1989. 68819–822.
31. Goodkind RJ, Keenan KM, Schwabacher WB. A comparison of Chromascan and spectrophotometric color measurement of 100 natural teeth. J Prosthet Dent 1985. 53105–109.
32. Schwabacher WB, Goodkind RJ. Three-dimensional color coordinates of natural teeth compared with three shade guide. J Prosthet Dent 1990. 64425–431.
33. Yeh CL, Powers JM, Miyagawa Y. Color of selected shades of composites by reflection spectrophotometry. J Dent Res 1982. 611176–1179.
34. Robertson AR. Colorimetry. Rep Prog Phys 1978. 41471–510.
35. Thornton WA. How strong metamerism disturbs color spaces. Color Res Appl 1998. 23402–407.
36. Park EJ. The basis of color molding 1996. 2nd edth ed. Seoul: Mijinsa; 56–194.
37. Park DY. Practical Chromatics 1992. Revised edth ed. Seoul: Bando publisher; 99–120.
38. The Korean Industrial Standard. KS A 0065

Article information Continued

Figure 1

Shade Map of the maxillary central incisors.

Figure 2

Shade Map of the maxillary lateral incisors.

Figure 3

Shade Map of the maxillary canines.

Figure 4

Shade Map of the maxillary first premolars.

Figure 5

Shade Map of the maxillary second premolars.

Figure 6

Repeated measurement of a central incisor.

Figure 7

Repeated measurement of a canine.

Figure 8

Shade Map of A1 shade guide on the black background (upper) and white background (below) according to thickness.

Figure 9

Shade Map of A3 shade guide on the black background (upper) and white background (below) according to thickness.

Table 1

Vita shade-guide colors (O'Brien et al.26, 1989)

Table 1

Table 2

CIE L*a*b* value of shade guides measured on the black background and white background

Table 2

Table 3

Color difference (ΔE*) of 3 mm thickness shade guide between measured on the black background and white background

Table 3

Table 4

Color difference (ΔE*) among shade guides that analysed as same Vita code

Table 4

A1 (1W) : 1 mm A1 shade guide analysed on white background

B3 (1B) : 1 mm B3 shade guide analysed on black background