Development of nano-fluid movement measuring device and its application to hydrodynamic analysis of dentinal fluid

Development of nano-fluid movement measuring device and its application to hydrodynamic analysis of dentinal fluid

Article information

Restor Dent Endod. 2008;33(2):141-147
Publication date (electronic) : 2008 March 31
doi : https://doi.org/10.5395/JKACD.2008.33.2.141
Department of Conservative Dentistry, School of Dentistry, Seoul National University, Korea.
Corresponding Author: In-Bog Lee. Department of Conservative Dentistry, School of Dentistry, Seoul National University, 275-1 Yeongeon-Dong, Jongno-Gu, Seoul 110-768, Korea. Tel: 82-2-2072-3953, Fax: 82-2-2072-3859, inboglee@snu.ac.kr
Received 2008 February 05; Revised 2008 March 03; Accepted 2008 March 08.

Abstract

This study was aimed to develop an instrument for real-time measurement of fluid conductance and to investigate the hydrodynamics of dentinal fluid. The instrument consisted of three parts; (1) a glass capillary and a photo sensor for detection of fluid movement, (2) a servo-motor, a lead screw and a ball nut for tracking of fluid movement, (3) a rotary encoder and software for data processing.

To observe the blocking effect of dentinal fluid movement, oxalate gel and self-etch adhesive agent were used. BisBlock (Bisco) and Clearfil SE Bond (Kuraray) were applied to the occlusal dentin surface of extracted human teeth. Using this new device, the fluid movement was measured and compared between before and after each agent was applied.

The instrument was able to measure dentinal fluid movement with a high resolution (0.196 nL) and the flow occurred with a rate of 0.84 to 15.2 nL/s before treatment. After BisBlock or Clearfil SE Bond was used, the fluid movement was decreased by 39.8 to 89.6%.

References

1. Roberson TM, Heymann HO, Swift EJ. Art and science of operative dentistry 2002. 4th edith ed. Mosby; 14–62.
2. Summitt JB, Robbins JW, Schwartz RS. Fundamentals of operative dentistry 2001. 2nd edith ed. Quintessence publishing co, Inc; 8–22.
3. Brännström M. Dentin and pulp in restorative dentistry 1981. Wolfe medical;
4. Hirata K, Nakashima M, Sekine I, Mukouyama Y, Kimura K. Dentinal fluid movement associated with loading of restorations. J Dent Res 1991. 70975–978.
5. Orchardson R, Cadden SW. An update on the physiology of the dentin-pulp complex. Dent Update 2001. 28200–209.
6. Brännstorm M, Lindén L, Johnson G. Movement of dentinal and pulpal fluid caused by clinical procedures. J Dent Res 1968. 5679–682.
7. Pashley DH, Derkson GD, Tao L, Kalathoor S. The effect of a multi-step dentin bonding system on dentin permeability. Dent Mater 1988. 460–63.
8. Sauro S, Pashley DH, Montanari , Chersoni S, Carvalho RM, Toledano M, Osorio R, Tay FR, Prati C. Effect of simulated pulpal pressure on dentin permeability and adhesion of self-etch adhesives. Dent Mater 2007. 23705–713.
9. Paphangkorakit J, Osborn JW. The effect of normal occlusal forces on fluid movement through human dentin in vitro. Arch Oral Biol 2000. 451033–1041.
10. De La Macorra JC, Escribano NI. Comparison of two methods to measure permeability of dentin. J Biomed Mater Res 2002. 63531–534.
11. Ozok AR, Wu MK, ten Cate JM, Wesselink PR. Effect of dentinal fluid composition on dentin demineralization in vitro. J Dent Res 2004. 83849–853.
12. Gregoire G, Joniot S, Guignes P, Millas A. Dentin permeability: self etching and one bottle dentin systems. J Prosthet Dent 2003. 9042–49.
13. Pashley DH, Matthews WG, Zhang Y, Johnson M. Fluid shifts across human dentin in vitro in response to hydrodynamic stimuli. Arch Oral Biol 1996. 411065–1072.
14. Ciucchi B, Bouillaguet S, Holz J, Pashley D. Dentinal fluid dynamics in human teeth, In vivo. J Endod 1995. 21191–193.
15. Kolker JL, Vargas MA, Armstrong SR, Dawson DV. Effect of desensitizing agents on dentin permeability and dentin tubule occlusion. J Adhes Dent 2002. 4211–221.
16. Ratih DN, Palamara JEA, Messer HH. Dentinal fluid flow and cuspal displacement in response to resin composite restorative procedures. Dent Mater 2007. 231405–1411.
17. Ratih DN, Palamara JEA, Messer HH. Temperature change, dentinal fluid flow and cuspal displacement during resin composite restoration. J Oral Rehab 2007. 34693–701.
18. Ciucchi B, Bouillaguet S, Delaloye M. Volume of the internal gap formed under composite restorations in vitro. J Dent 1997. 25305–312.
19. Martin RL, Brackett WW, Loushine RJ, Rockman RA, Ferrari M, Pashley DH, Tay FR. Sealing properties of mineral trioxide aggregate orthograde apical plugs and root fillings in an in vitro apexification model. J Endod 2007. 33272–275.
20. Beneson W, Harris JW, Stocken H, Lutz H. Handbook of physics 2006. Springer; 153–210.
21. Breschi L, Mazzoni A, Ruggeri A, Cadenaro M, Linarda RD, Dorigo EDS. Dental adhesion review: Aging and stability of bonded interface. Dent Mater 2008. 2490–101.
22. Tay FR, Pashley DH. Water treeing-a potential mechanism for degradation of dentin adhesives. Am J Dent 2003. 166–12.

Article information Continued

Figure 1-a

Schematic diagram of the nano-flow measurement device.

Figure 1-b

Circuit diagram of photo sensor and servo amplifier.

Figure 2

Representative curves of dentinal fluid flow before and after application of BisBlock (a) or Clearfil SE bond (b).

Table 1

Water flow (nL) during 300 s and mean flow rate (nL/s) through dentin before and after application of BisBlock or Clearfil SE bond on the exposed dentin surface

Table 1