Warning: mkdir(): Permission denied in /home/virtual/lib/view_data.php on line 81

Warning: fopen(upload/ip_log/ip_log_2024-12.txt): failed to open stream: No such file or directory in /home/virtual/lib/view_data.php on line 83

Warning: fwrite() expects parameter 1 to be resource, boolean given in /home/virtual/lib/view_data.php on line 84
Microleakage of composite resin restoration according to the number of thermocycling

Microleakage of composite resin restoration according to the number of thermocycling

Article information

Restor Dent Endod. 2007;32(4):377-384
Publication date (electronic) : 2007 July 31
doi : https://doi.org/10.5395/JKACD.2007.32.4.377
Department of Conservative Dentistry, College of Dentistry, Dankook University, Korea.
Corresponding Author: Dong-Hoon Shin. Department of Conservative Dentistry, College of Dentistry, Dankook University, 7-1 Shinbu-dong, Cheonan, Chungnam, 330-716, Korea. Tel: 82-41-550-1965, Fax: 82-41-550-1963, donyshin@dankook.ac.kr
Received 2007 June 12; Revised 2007 June 27; Accepted 2007 June 28.

Abstract

Present tooth bonding system can be categorized into total etching bonding system (TE) and self-etching boding system (SE) based on their way of smear layer treatment. The purposes of this study were to compare the effectiveness between these two systems and to evaluate the effect of number of themocycling on microleakage of class V composite resin restorations.

Total forty class V cavities were prepared on the single-rooted bovine teeth and were randomly divided into four experimental groups: two kinds of bonding system and another two kinds of thermocycling groups. Half of the cavities were filled with Z250 follwing the use of TE system, Single Bond and another twenty cavities were filled with Metafil and AQ Bond, SE system. All composite restoratives were cured using light curing unit (XL2500, 3M ESPE, St. Paul, MN, USA) for 40 seconds with a light intensity of 600 mW/cm2.

Teeth were stored in distilled water for one day at room temperature and were finished and polished with Sof-Lex system. Half of teeth were thermocycled 500 times and the other half were thermocycled 5,000 times between 5℃ and 55℃ for 30 second at each temperature.

Teeth were isolated with two layers of nail varnish except the restoration surface and 1 mm surrounding margins. Electrical conductivity (µA) was recorded in distilled water by electrochemical method. Microleakage scores were compared and analyzed using two-way ANOVA at 95% level.

From this study, following results were obtained: There was no interaction between variables of bonding system and number of thermocycling (p = 0.485). Microleakage was not affected by the number of thermocycling either (p = 0.814). However, Composite restoration of Metafil and AQ Bond, SE bond system showed less microleakage than composite restoration of Z250 and Single Bond, TE bond system (p = 0.005).

References

1. Buonocore MG. A simple method of increasing the adhesion of acrylic filling materials to enamel surfaces. J Dent Res 1955. 34849–853.
2. Mjör IA. Human coronal dentine: structure and reactions. Oral Surg Oral Med Oral Pathol 1972. 33810–823.
3. Gwinnett AJ, Jendresen MD. Micromorphological features of cervical erosion after acid conditioning and its relation with composite resin. J Dent Res 1978. 57543–549.
4. Fusayama T, Nakamura M, Kurosaki N, Iwaku M. Non-pressure adhesion of a new adhesive restorative resin. J Dent Res 1979. 581364–1370.
5. Shimada Y, Iwamoto N, Kawashima M, Burrow MF, Tagami J. Shear bond strength of current adhesive systems to enamel, dentin and dentin-enamel junction region. Oper Dent 2003. 28585–590.
6. Tay FR, Gwinnett AJ, Wei SH. The overwet phenomenon: an optical, micromorphological study of surface moisture in the acid-conditioned, resin-dentin interface. Am J Dent 1996. 943–48.
7. Perdigão J, Van Meerbeek B, Lopes MM, Ambrose WW. The effect of a re-wetting agent on dentin bonding. Dent Mater 1999. 15282–295.
8. Frankenberger R, Sindel J, Krjämer N, Petschelt A. Dentin bond strength and marginal adaptation: Direct composite resins vs. ceramic inlays. Oper Dent 1999. 24147–155.
9. Swift EJ, Wilder AD, May KN, Waddell SL. Shear bond strengths of one-bottle dentin adhesives using multiple applications. Oper Dent 1997. 22194–199.
10. Brunton PA, Cowan AJ, Wilson MA, Wilson NH. A three-year evaluation of restorations placed with a smear layer-mediated dentin bonding agent in non-carious cervical lesions. J Adhes Dent 1999. 1333–341.
11. Spencer P, Wang Y, Walker MP, Wieliczka DM, Swafford JR. Interfacial chemistry of the dentin/adhesive bond. J Dent Res 2000. 791458–1463.
12. Watanabe I, Nakabayashi N, Pashley DH. Bonding to ground dentin by a phenyl-P self-etching primer. J Dent Res 1994. 731212–1220.
13. Torii Y, Itou K, Nishitani Y, Ishikawa K, Suzuki K. Effect of phosphoric acid etching prior to self-etching primer application on adhesion of resin composite to enamel and dentin. Am J Dent 2002. 15305–308.
14. Erhardt MC, Cavalcante LM, Pimenta LA. Influence of Phosphoric Acid Pretreatment on Self-Etching Bond Strengths. J Esthet Restor Dent 2004. 1633–40.
15. Ernst CP. Positioning self-etching adhesives: versus or in addition to phosphoric acid etching? J Esthet Restor Dent 2004. 1657–69.
16. Brackett WW, Haisch LD, Pearce MG, Brackett MG. Microleakage of Class V resin composite restorations placed with self-etching adhesives. J Prosthet Dent 2004. 9142–45.
17. Fabianelli A, Kugel G, Ferrari M. Efficacy of self-etching primer on sealing margins of class II restorations. Am J Dent 2003. 1637–41.
18. Santini A, Plasschaert AJ, Mitchell S. Effect of composite resin placement techniques on the microleakage of two self-etching dentin-bonding agents. Am J Dent 2001. 14132–136.
19. Cardoso PE, Placido E, Francci CE, Perdigao J. Microleakage of class V resin-based composite restorations using five simplified adhesive systems. Am J Dent 1999. 12291–294.
20. Turkun SL. Clinical evaluation of a self-etching and a one-bottle adhesive system at two years. J Dent 2003. 31527–534.
21. Crim GA, Chapman KW. Reducing microleakage in class II restorations: an in vitro study. Quintessence Int 1994. 25781–785.
22. Iwami Y, Yamamoto H, Ebisu S. A new electrical method for detecting marginal leakage of in vitro resin restorations. J Dent 2000. 28241–247.
23. Mattison GD, von Fraunhofer JA. Electrochemical microleakage study of endodontic sealer/cements. Oral Surg Oral Med Oral Pathol 1983. 55402–407.
24. Iwami Y, Yamamoto H, Ebisu S. A new electrical method for detecting marginal leakage of in vitro resin restorations. J Dent 2000. 28241–247.
25. Nakano Y. A new electrical testing method on marginal leakage of composite resin restorations. Jpn J Conserv Dent 1985. 81183–1198.
26. Delivanis PD, Chapman KA. Comparison and reliability of techniques for measuring leakage and marginal penetration. Oral Surg Oral Med Oral Pathol 1982. 53410–416.
27. Gueders AM, Charpentier JF, Albert AI, Geerts SO. Microleakage after thermocycling of 4 etch and rinse and 3 self-etch adhesives with and without a flowable composite lining. Oper Dent 2006. 31450–455.
28. Besnault C, Attal JP. Influence of a simulated oral environment on microleakage of two adhesive systems in Class II composite restorations. J Dent 2002. 301–6.
29. Bedran-de-Castro AK, Cardoso PE, Ambrosano GM, Pimenta LA. Thermal and mechanical load cycling on microleakage and shear bond strength to dentin. Oper Dent 2004. 2942–48.
30. Aguiar FH, Dos Santos AJ, Franca FM, Paulillo LA, Lovadino JR. A quantitative method of measuring the microleakage of thermocycled or non-thermocycled posterior tooth restorations. Oper Dent 2003. 28793–789.
31. Pazinatto FB, Campos BB, Costa LC, Atta MT. Effect of the number of thermocycles on microleakage of resin composite restorations. Pesqui Odontol Bras 2003. 17337–341.
32. Koyuturk AE, Akca T, Yucel AC, Yesilyurt C. Effect of thermal cycling on microleakage of a fissure sealant polymerized with different light sources. Dent Mater J 2006. 25713–718.
33. Miyazaki M, Sato M, Onose H, Moore BK. Influence of thermal cycling on dentin bond strength of two-step bonding systems. Am J Dent 1998. 11118–122.

Article information Continued

Figure 1

Schematic drawing of electrochemical test.

Table 1

Component of dentin bonding systems

Table 1

Table 2

Currents from electrochemical test (µA)

Table 2

Different letters means statistically significant differences (p < 0.05)

Table 3

Two-way ANOVA result

Table 3

Table 4

Currents between restoratives (µA)

Table 4

Different letters means statistically significant differences (p < 0.05)