References
1. Schilder H. Cleaning and shaping the root canal. Dent Clin North Am 1974. 18269–296.
2. Skidmore AE, Bjorndal AM. Root canal morphology of the human mandibular first molar. Oral Surg Oral Med Oral Pathol 1971. 32778–784.
3. Weine F, Kelly R, Lio P. The effect of preparation procedures on the original canal shape and on apical foramen shape. J Endod 1975. 1255–262.
4. Walia H, Brantely WA, Gerstein H. An initial investigation of the bending and torsional properties of nitinol root canal files. J Endod 1988. 14346–351.
5. Glossen CR, Haller RH, Dove SB, del Rio CE. A comparison of root canal preparations using Ni-Ti hand, Ni-Ti engine-driven, and K-Flex endodontic instruments. J Endod 1995. 21146–151.
6. Serene TP, Adams JD, Saxena A. Nickel-titanium instruments: applications in endodontics 1995. St. Louis: Mosby; 67–78.
7. Barbakow F, Lutz F. The "Lightspeed" preparation technique evaluated by Swiss clinicians after attending continuing education courses. Int Endod J 1997. 3046–50.
8. Zuolo ML, Walton RE. Instrument deterioration with usage: Nickel-Titanium versus stainless steel. Quintessence Int 1997. 28397–402.
9. Mandel E, Adib-Yazdi M, Benhamou LM, Lachkar T, Mesgouez , Sobel M. Rotary Ni-Ti profile systems for preparing curved canals in resin blocks: influence of operator on instrument breakage. Int Endod J 1999. 32436–443.
10. Ruddle C. Cleaning and shaping the root canal system. Pathways of the Pulp 2002. 8th edth ed. Mosby: St. Louis; 231–292.
11. Sattapan B, Nervo GJ, Palamara JEA, Messer HH. Defect in rotary nickel-titanium files after clinical use. J Endod 2000. 26161–165.
12. Haikel Y, Serfaty R, Bateman G, Senger B, Allemann C. Dynamic and cyclic fatigue of engine-driven rotary nickel-titanium endodontic instrument. J Endod 1999. 25434–440.
13. Gambarini G. Cyclic fatigue of Profile rotary instruments after prolonged clinical use. Int Endod J 2001. 34386–389.
14. Pruett JP, Clement DJ, Carnes DL Jr. Cyclic fatigue testing of nickel-titanium endodontic instruments. J Endod 1997. 2377–85.
15. Gary C. Influence of material properties on the rotational speed of engine-driven nickel-titanium instrument. Contemporary Endod 2002. 28–30.
16. Mize SB, Clement DJ, Carnes DL, Pruett JP. Effect of sterilization on cyclic fatigue of Ni-Ti instruments. Abstracts of research. AAE 54th session. J Endod 1997. 23(OR9)251.
17. Yared GM, Bou Dagher FE, Machtou P. Cyclic fatigue of Profile rotary instruments after clinical use. Int Endod J 2000. 33204–207.
18. Peters OA, Barbakow F. Dynamic torque and apical forced of ProFile .04 rotary instruments during preparation of curved canals. Int Endod J 2002. 35379–389.
19. Booth JR, Sheetz JP, Lemons JE, Eleazer PD. A comparison of torque reqiured to fracture three different nickel-titanium rotary instruments around curves of the same angle but of different radius when bound at the tip. J Endod 2003. 2955–57.
20. Gambarini G. Cyclic fatique of nickel-titanium rotary instruments after clinical use with low- and high torque endodontic motors. J Endod 2001. 27772–774.
21. Cho JC, et al. Metal Failure Analysis 2002. Seoul: Jinyoungsa; 15–41.
22. Lee DR. Mechanical Metallurgy 1985. Seoul: Moonundang; 219–291.
23. Zinelis S, Margelos J. In : Eliades G, Eliades T, Brantley W, Watt DC, eds. Aging of endodontic instruments and materials. Dental materials in vivo: aging and related phenomena. Carol Stream 2003. Carol Stream: Quintessence Publishing Co Inc; 180–186.