Warning: mkdir(): Permission denied in /home/virtual/lib/view_data.php on line 81

Warning: fopen(upload/ip_log/ip_log_2024-12.txt): failed to open stream: No such file or directory in /home/virtual/lib/view_data.php on line 83

Warning: fwrite() expects parameter 1 to be resource, boolean given in /home/virtual/lib/view_data.php on line 84
A 3-year retrospective study of clinical durability of bulk-filled resin composite restorations

A 3-year retrospective study of clinical durability of bulk-filled resin composite restorations

Article information

Restor Dent Endod. 2022;47.e5
Publication date (electronic) : 2021 December 30
doi : https://doi.org/10.5395/rde.2022.47.e5
Department of Restorative Dentistry, Faculty of Dentistry, Süleyman Demirel University, Isparta, Turkey.
Correspondence to Muhittin Ugurlu, DDS. Assistant Professor, Department of Restorative Dentistry, Faculty of Dentistry, Süleyman Demirel University, East Campus, Isparta 32200, Turkey. dtmuhittinugurlu@gmail.com
Received 2021 May 21; Revised 2021 July 07; Accepted 2021 July 18.

Abstract

Objectives

This study aimed to assess the clinical longevity of a bulk-fill resin composite in Class II restorations for 3-year.

Materials and Methods

Patient record files acquired from the 40 patients who were treated due to needed 2 similar sizes Class II composite restorations were used for this retrospective study. In the experimental cavity, the flowable resin composite SDR was inserted in the dentinal part as a 4 mm intermediate layer. A 2 mm coverage layer with a nano-hybrid resin composite (CeramX) was placed on SDR. The control restoration was performed by an incremental technique of 2 mm using the nano-hybrid resin composite. The restorations were blindly assessed by 2 calibrated examiners using modified United States Public Health Service criteria at baseline and 1, 2, and 3 years. The data were analyzed using non-parametric tests (p = 0.05).

Results

Eighty Class II restorations were evaluated. After 3-years, 4 restorations (5%) failed, 1 SDR + CeramX, and 3 CeramX restorations. The annual failure rate (AFR) of the restorations was 1.7%. The SDR + CeramX group revealed an AFR of 0.8%, and the CeramX group an AFR of 2.5% (p > 0.05). Regarding anatomical form and marginal adaptation, significant alterations were observed in the CeramX group after 3-years (p < 0.05). The changes in the color match were observed in each group over time (p < 0.05).

Conclusions

The use of SDR demonstrated good clinical durability in deep Class II resin composite restorations.

INTRODUCTION

In dentistry, resin composites are frequently used for the restoration of posterior teeth besides anterior teeth due to esthetics and enhanced mechanical properties [12]. However, the posterior resin composite restorations might be failed because of different causes, such as mainly material fracture and recurrent caries [3]. The fracture is an important reason for resin composite restoration failure from the second year of restoration, and the cause of failure that appeared in later years is caries [3]. The material-dependent factors have a crucial influence on the survival of the restoration [4].

Most of the resin composites are nowadays methacrylate-based and polymerize through a free radical reaction [56]. A rigid polymer network forms since increasing the cross-linking of the polymer chains during the polymerization [7]. Moreover, the shrinkage stresses occur as a consequence of the polymerization shrinkage by the conversion of monomer molecules into the polymers [7]. The polymerization shrinkage stress may lead to marginal defects, cusp fractures, microleakage, post-operative sensitivity, and secondary caries by concentrating at the adhesive interface [8]. The cure depth of the resin composite also has a great influence on the clinical success of the restoration because of affecting the physical properties of the material [9].

Various modified placement and polymerization strategies have lately been developed to reduce polymerization shrinkage stress formation on the adhesive interface by decreasing the C-factor and improving the degree of cure [810]. The resin composites traditionally are gradually placed in layers of 2 mm with horizontal or oblique technique [11]. These layering approaches might provide optimal polymerization and conversion rate through better light penetration, and decrease the cuspal deflection by reducing polymerization shrinkage stresses and the cavity configuration factor [910]. The clinical evidence about the clinical efficacy of these techniques is weak [91011]. The layering techniques might become time-consuming in the restoration of deep posterior cavities and cause void formation between layers, thus; increasing failure risk [8912]. The application of resin composites with thicker increments causes inadequate cure of the material in the deeper parts, influences adversely the mechanical characteristics of the restoration, and causes elution of more monomer [912]. Extensive efforts have been made to develop resin composites that have more improved properties and ease of application [8].

Bulk-fill resin composites have recently been developed to simplify the restorative technique because they may be placed in a single increment of 4–5 mm [5]. The bulk-fill composites are divided into 2 groups, the low- and high-viscosity materials. There is a need for a final occlusal layer of conventional resin composite for the low viscosity bulk-fill resin composites, but it is not required for the high viscous ones [511]. The first introduced stress-relieving resin technology-based low viscosity bulk-fill resin composite is SDR (Dentsply/DeTrey, Konstanz, Germany), which is used in 4 mm layers by covering the occlusal surface with a conventional resin composite [6]. The flowable bulk-fill resin composite SDR involves a modulator for the polymerization reaction, which is a patented urethane di-methacrylate (UDMA) and provides a relatively slow radical polymerization rate [6]. The slow polymerization rate allows a slower modulus formation, thus providing stress reduction without reducing the conversion rate [613]. The rheology of the material might also ensure its enhanced adaptation to the cavity walls by hindering the occurrence of voids at the tooth-restoration interface [8]. Moreover, using SDR as a base material under conventional resin composite may facilitate the placement of resin composite in deep cavities by overcoming the disadvantages of layering techniques, thus shortening the treatment time required for restoration.

Previous laboratory studies have reported that SDR revealed lower shrinkage stress and shrinkage-rate values in comparison to conventional methacrylate-based resin composites, and the bulk filling technique with SDR showed similar performance with the incremental layering techniques [6121314]. A few clinical reports are available about the clinical performance of SDR. According to the clinical evidence, the bulk-filling technique with SDR has shown highly acceptable clinical performance and efficacy comparable with layering techniques [891011]. Nonetheless, more clinical studies are necessary to validate the clinical performance and effectiveness of restorative materials. Therefore, this retrospective study aimed to investigate the clinical longevity of the use of SDR as a base under a conventional resin composite in Class II cavities for 3-year and to compare with 2 mm layering technique. The null hypothesis tested was that that the 3-year clinical durability of the restorations made with the bulk-fill technique using SDR and the 2 mm thick oblique layering technique would be similar.

MATERIALS AND METHODS

This retrospective study was designed as a comparative evaluation of Class II resin composite restorations performed using SDR and a conventional resin composite. The study design and protocol were approved by the local ethics committee (2021/126). The patient record files of 40 patients with a mean age of 30.1 years (range 21–40) saved by one of the authors were used for collecting data for this retrospective study. Included in the study were patients who were treated by one same experienced operator between March and August 2017 due to needed only 2 similar size Class II resin composite restorations and attended the practice for follow-up recalls at 1-week, 1, 2, and 3 years. For this study, some participant was already excluded due to high caries risk, poor periodontal health, parafunctional habits, or pregnancy. The patient who had only one and more than 2 Class II cavities needing to be filled was also not included in this study. Two similar deep and extended-sized restorations as possible were made for each patient, due to carious lesions and defective restorations requiring replacement. The randomization of the experimental or control restorative materials was performed using a table of random numbers for each patient before the operative procedure. The participants were not knowledgeable regarding which cavity was restored with the experimental and control material. In the experimental cavity, the flowable resin composite SDR (Dentsply/DeTrey) was inserted into the cavity in 4 mm thickness, and a 2 mm final layer of a nano-hybrid resin composite (CeramX; Dentsply/DeTrey) was placed on the occlusal part. The control restoration was done with a 2-mm incremental layering technique using the nano-hybrid resin composite. All teeth had proximal contact with adjacent teeth and were in occlusion. A total of 40 pairs of restorations was considered to be adequate and comparable with previous studies [810].

Clinical procedure and evaluation

Following the isolation of the operative field with a rubber dam, the existing restorations and/or caries were removed under constant water cooling without any bevel preparation on the cavities. The thin metallic matrices (Tor VM, Moscow, Russia) and wooden wedges (KerrHawe, Bioggio, Switzerland) were used. Any base materials were applied in none of the cavities. For selective enamel etching, a 35% phosphoric acid gel (Scotchbond Universal Etchant; 3M Oral Care, St. Paul, MN, USA) was applied on enamel for 15 seconds. Application of the 2-step self-etching adhesive Clearfil SE Bond (Kuraray, Tokyo, Japan) in all cavities was performed according to the manufacturer's instructions (Table 1). The adhesive was light-cured by a light-curing unit (Smartlite Focus, 1,000 mW/cm2; Dentsply/DeTrey) for 10 seconds. The output of the light-curing unit was checked after each patient by a radiometer. In experimental SDR restoration, the flow material was placed in bulk increments up to 4 mm until there was a gap of 2 mm in the occlusal surface and light-cured with the light-curing unit for 20 seconds (Smartlite Focus). The 2 mm superficial occlusal layer of the restoration was finished off with the CeramX resin composite material. In the control cavity, the resin composite CeramX was placed in 2 mm layers with an oblique layering technique and light-cured according to manufacturers' instructions. After the occlusion checking and contouring, the polishing was done using a polishing system (OneGloss; Shofu, Kyoto, Japan).

The materials, chemical composition and application procedure

The restorations were assessed at baseline (1 week after placement of the restorations) and after 1, 2, and 3 years by the following parameters by modified United States Public Health Service (USPHS) criteria (Table 2) as in previous studies [891011]: anatomic form, marginal adaptation, marginal discoloration, surface roughness, color match, and secondary caries. The follow-up registrations were performed blindly by 2 calibrated evaluators. There was a strong congruence between the evaluators. The Cohen's kappa coefficient between evaluators was 0.92, 0.88, 0.92, and 0.90 at the evaluation periods, respectively, revealing that there was a concordance of kappa. The evaluators did not know which experimental, or which control group the scoring concerned during the evaluation periods.

Modified USPHS criteria for direct clinical evaluation

Statistical analysis

The data were analyzed using the SPSS Program, version 20.0 (Statistical Package for the Social Sciences; SPSS, Chicago, IL, USA). The properties of the restorations were characterized by descriptive statistics with cumulative frequency distributions of the scores. The experimental and control restorative techniques at the same evaluation period were compared via the Mann-Whitney U test. The analysis of data acquired by the same restorative techniques at different evaluation times was performed through the nonparametric Friedman's 2-way analysis of variance test. The statistical significance level was set up at 0.05 for all analyses.

RESULTS

During the 3-year follow-up, 80 Class II restorations were evaluated. The distribution of the restored teeth is displayed in Table 3. Any of the participants reported any postoperative symptoms at the evaluation times. After 3-years, 4 restorations (5%) were failed; 1 SDR + CeramX, and 3 CeramX restorations. The annual failure rate (AFR) of the restorations was 1.7%. The SDR+ CeramX group showed an AFR of 0.8%, and the CeramX group an AFR of 2.5%. Two of the restoration failures were observed in female participants. The reason and tooth type for the failure of the failed restorations are given in Table 4. The main reason for failure was partial fractures in the resin composite. No carious lesions observed were found contiguous with the restorations. The modified USPHS scores of the restorations are given in Table 5. There were no statistically significant differences between the experimental and control restoration groups in all evaluation times (p > 0.05). However, there were some differences within each group. Regarding anatomical form and marginal adaptation, significant alterations were observed over time in the CeramX group (p < 0.05). The color match besides changed significantly during the follow-up in the 2 groups (p < 0.05). No significant differences were found in other criteria over time in the 2 groups (p > 0.05).

Distribution of the restored teeth

The failed restorations after 3-year, tooth type and reason for failure

Scores for the evaluated Class II restorations at baseline and after 1, 2, and 3 years of CeramX and SDR + CeramX given as relative frequencies (%)

DISCUSSION

In the present study, the 3-year clinical longevity of the use of SDR in large and deep Class II cavities was evaluated by comparing with the nano-hybrid resin composite restoration built up with a 2 mm layering technique. A 0.8% AFR was observed in the bulk-filled restorations whereas the resin composite-only group was showed a 2.5% AFR. There was no statistical difference among the restorations with and without SDR during all evaluation periods. Therefore, the null hypothesis that the 3-year clinical durability of the restorations made with the bulk-fill technique using SDR and the 2 mm thick oblique layering technique would be similar was accepted.

The standard 2-mm incremental placement technique is frequently used to acquire adequate light penetration and reduce shrinkage stress in conventional resin composite restorations despite the incremental filling techniques have some disadvantages during clinical procedures [910]. It has been reported that the oblique layering technique induced more stress concentration than the horizontal filling technique at the interface [1516]. Nevertheless, the stress-decreasing influence of these techniques is also not clear [11]. A previous study has additionally shown that additional increments enhanced the risk of cuspal deformation on the weakened cusps [16]. The bulk-fill resin composites have been developed to overcome the disadvantages of layering techniques and ease the resin composite restoration procedure [5]. One of the first introduced bulk-fill resin composites, the flowable resin composite SDR was employed in this study. SDR may be used in a single increment of 4 mm thanks to its higher translucency and having the modified UDMA [61317]. SDR has UDMA incorporating a photoactive group, which allows a comparatively slow radical polymerization rate [6]. Previous studies have concluded that SDR showed a lower polymerization shrinkage stress and shrinkage rate than conventional resin composites because of the incorporation of the polymerization modulator, which has a high molecular weight to the center of the polymerizable group of the monomer [6181920]. The low shrinkage stress might also provide higher dentin bond strength to SDR compared with conventional resin composites [1721]. Furthermore, it has been reported that the use of SDR decreased cuspal deflection in Class II cavities in comparison with resin composite restorations which were made with an oblique layering technique [14].

The interfacial adaptation is also an essential factor for the longevity of a restoration besides shrinkage stress [22]. The poor interfacial adaptation might lead to microleakage, postoperative sensitivity, and secondary caries [8]. It has been reported that the SDR ensured better adaptation to the cavity walls than the conventional resin composite due to its flowability [2223]. Besides, the enhanced depth of cure influences the clinical success of the bulk-filled resin composites. The bulk filling technique might not provide adequate post-cure depth when the material translucency is low, resulting in lower mechanical properties of the material [24]. The increased translucency of SDR might provide enough curing efficacy up to a single increment of 4 mm doing so increasing the longevity of restorations by obtaining satisfactory mechanical and physical properties [61317]. However, the occlusal capping layer on SDR with a conventional resin composite is necessary because the modulus of elasticity and hardness of SDR is lower than the conventional resin composites due to its lower filler loading [25]. Although the occlusal capping layer is necessary for SDR, the use of a conventional resin composite together with SDR might reduce treatment time in 6 mm and deeper cavities comparing the conventional layering techniques. The low elasticity modulus of SDR might also increase the longevity of the restoration by absorbing and relieving the occlusal stresses.

A 3-year period might be not sufficient time to assess the clinical performance of resin composite restorations [3]. However, only a few clinical studies are available, which were performed to investigate the clinical performance of the bulk-filled resin composite SDR. These studies have concluded that the bulk-filling with SDR demonstrated similar durability as the restorations performed with conventional 2 mm layering technique, and the difference between the 2 restoration groups in each cavity class (Class I and II) was not significant [891011]. In the present study, only deep Class II cavities were included because of the observed low failure rate of Class I restorations [10]. The AFRs for restorations in this study were similar to the AFRs found in previous studies, which have reported AFRs varying between 1.7-3.3% for restorations performed with the 2-mm incremental layering technique [262728293031]. In the present study, the CeramX group showed an AFR of 2.5%, SDR + CeramX group showed an AFR of 0.8%. Previous randomized clinical trials in which evaluated the performance of SDR with 4 mm layering technique have reported AFRs varying between 0%–2.2% in Class II cavities [891011].

In the present study, a significant alteration was found in the color match in each group during the follow-up, as reported in previous studies [89], but some minor discrepancies in the color match were clinically acceptable. The group in which restorations were performed using CeramX with a 2-mm layering technique presented significant alterations in anatomical form and marginal adaptation over time. Following 3-years, 1 SDR + CeramX and 3 CeramX restorations were failed. It may be due to the low elasticity modulus of SDR, decreasing polymerization shrinkage stresses and, thereby, maintaining the marginal integrity, as attributed in previous studies [232]. The lower polymerization stresses of the bulk-fill resin composites might particularly promote better marginal adaptation for restorations [56]. The enhanced deep of cure of SDR might also provide higher mechanical properties for the restorations [1011]. A previous study has concluded that the occurrence of catastrophic failures was observed in the conventional nano-hybrid resin composite restorations with a 2 mm layering technique due to not-optimal conversion in the deeper layers whereas no catastrophic failure occurred in the bulk filling technique with SDR [8]. In this study, the main reason for failure was partial fractures in the material. It has been reported that the material fracture more occurred in bruxing participants [910]. However, bruxing-risk participants were not included in the present study. Furthermore, the decreases in the polymerization shrinkage stress thanks to bulk-fill resin composites may affect postoperative sensitivity [33]. Nevertheless, in this study, the participants reported no postoperative sensitivity during any evaluation periods. The result of this study is in agreement with previous studies in which the use of SDR showed good and acceptable clinical durability [891011].

An important factor contributing to the increased longevity of resin composite restorations is the bonding efficiency of the adhesives and adhesive strategy [3]. In this study, the mild 2-step self-etch adhesive Clearfil SE Bond defined as a gold-standard 2-step self-etch adhesive [34] was used with the selective etching technique. Because it has been reported that this adhesive showed highly good clinical performance when used with selective acid-etching of the enamel cavity margins [35].

In this study, the modified USPHS criteria were employed to investigate the survival of restorations, as in several clinical studies [891011]. The kappa test showed good agreement between the evaluators, as in a previous study [2]. There are some limitations in the present study. Only 40 patients were treated and evaluated. The patients who had good oral health and low caries risk were included. Besides, the patients who had parafunctional habits were excluded. Therefore, further clinical studies should be performed to investigate the performance of SDR placed in other types of cavities and patients with parafunctional habits and high caries risk. Moreover, longer-term clinical studies are necessary to verify the clinical performance of SDR.

CONCLUSIONS

Within the scope of this study, although the long-term results are not still available, the following conclusion might be drawn: The clinical longevity of the use of SDR in Class II cavities for 3-year was similar to 2-mm incremental oblique layering technique. The use of SDR may provide an advantage in the reduction of the required time for resin composite restoration procedures in deep posterior cavities.

Notes

Conflict of Interest: No potential conflict of interest relevant to this article was reported.

Author Contributions:

  • Conceptualization: Data curation.

  • Formal analysis: Ugurlu M, Sari F.

  • Funding acquisition: Ugurlu M.

  • Investigation: Ugurlu M.

  • Methodology: Ugurlu M, Sari F.

  • Project administration: Ugurlu M.

  • Resources: Ugurlu M.

  • Software: Ugurlu M.

  • Supervision: Ugurlu M.

  • Validation: Ugurlu M.

  • Visualization: Ugurlu M.

  • Writing - original draft: Ugurlu M, Sari F.

  • Writing - review & editing: Ugurlu M.

References

1. Sunnegårdh-Grönberg K, van Dijken JW, Funegård U, Lindberg A, Nilsson M. Selection of dental materials and longevity of replaced restorations in Public Dental Health clinics in northern Sweden. J Dent 2009;37:673–678. 19477572.
2. Frascino S, Fagundes TC, Silva U, Rahal V, Barboza A, Santos PH, Briso A. Randomized prospective clinical trial of class ii restorations using low-shrinkage flowable resin composite. Oper Dent 2020;45:19–29. 31034347.
3. Opdam NJ, van de Sande FH, Bronkhorst E, Cenci MS, Bottenberg P, Pallesen U, Gaengler P, Lindberg A, Huysmans MC, van Dijken JW. Longevity of posterior composite restorations: a systematic review and meta-analysis. J Dent Res 2014;93:943–949. 25048250.
4. Pallesen U, van Dijken JW, Halken J, Hallonsten AL, Höigaard R. Longevity of posterior resin composite restorations in permanent teeth in Public Dental Health Service: a prospective 8 years follow up. J Dent 2013;41:297–306. 23228499.
5. Van Ende A, De Munck J, Lise DP, Van Meerbeek B. Bulk-fill composites: a review of the current literature. J Adhes Dent 2017;19:95–109. 28443833.
6. Ilie N, Hickel R. Investigations on a methacrylate-based flowable composite based on the SDR™ technology. Dent Mater 2011;27:348–355. 21194743.
7. Braga RR, Ballester RY, Ferracane JL. Factors involved in the development of polymerization shrinkage stress in resin-composites: a systematic review. Dent Mater 2005;21:962–970. 16085301.
8. van Dijken JW, Pallesen U. A randomized controlled three year evaluation of “bulk-filled” posterior resin restorations based on stress decreasing resin technology. Dent Mater 2014;30:e245–e251. 24958689.
9. van Dijken JW, Pallesen U. Bulk-filled posterior resin restorations based on stress-decreasing resin technology: a randomized, controlled 6-year evaluation. Eur J Oral Sci 2017;125:303–309. 28524243.
10. van Dijken JW, Pallesen U. Randomized 3-year clinical evaluation of Class I and II posterior resin restorations placed with a bulk-fill resin composite and a one-step self-etching adhesive. J Adhes Dent 2015;7:81–88.
11. van Dijken JW, Pallesen U. Posterior bulk-filled resin composite restorations: a 5-year randomized controlled clinical study. J Dent 2016;51:29–35. 27238052.
12. El-Safty S, Silikas N, Watts DC. Creep deformation of restorative resin-composites intended for bulk-fill placement. Dent Mater 2012;28:928–935. 22656273.
13. Czasch P, Ilie N. In vitro comparison of mechanical properties and degree of cure of bulk fill composites. Clin Oral Investig 2013;17:227–235.
14. Moorthy A, Hogg CH, Dowling AH, Grufferty BF, Benetti AR, Fleming GJ. Cuspal deflection and microleakage in premolar teeth restored with bulk-fill flowable resin-based composite base materials. J Dent 2012;40:500–505. 22390980.
15. Abbas G, Fleming GJ, Harrington E, Shortall AC, Burke FJ. Cuspal movement and microleakage in premolar teeth restored with a packable composite cured in bulk or in increments. J Dent 2003;31:437–444. 12878027.
16. Versluis A, Douglas WH, Cross M, Sakaguchi RL. Does an incremental filling technique reduce polymerization shrinkage stresses? J Dent Res 1996;75:871–878. 8675797.
17. Van Ende A, De Munck J, Van Landuyt KL, Poitevin A, Peumans M, Van Meerbeek B. Bulk-filling of high C-factor posterior cavities: effect on adhesion to cavity-bottom dentin. Dent Mater 2013;29:269–277. 23228335.
18. Ilie N, Keßler A, Durner J. Influence of various irradiation processes on the mechanical properties and polymerisation kinetics of bulk-fill resin based composites. J Dent 2013;41:695–702. 23707645.
19. Alshali RZ, Silikas N, Satterthwaite JD. Degree of conversion of bulk-fill compared to conventional resin-composites at two time intervals. Dent Mater 2013;29:e213–e217. 23845799.
20. Kim RJ, Kim YJ, Choi NS, Lee IB. Polymerization shrinkage, modulus, and shrinkage stress related to tooth-restoration interfacial debonding in bulk-fill composites. J Dent 2015;43:430–439. 25676178.
21. Kumagai RY, Zeidan LC, Rodrigues JA, Reis AF, Roulet JF. Bond strength of a flowable bulk-fill resin composite in Class II MOD cavities. J Adhes Dent 2015;7:427–432.
22. Francis AV, Braxton AD, Ahmad W, Tantbirojn D, Simon JF, Versluis A. Cuspal flexure and extent of cure of a bulk-fill flowable base composite. Oper Dent 2015;40:515–523. 25741908.
23. Fronza BM, Rueggeberg FA, Braga RR, Mogilevych B, Soares LE, Martin AA, Ambrosano G, Giannini M. Monomer conversion, microhardness, internal marginal adaptation, and shrinkage stress of bulk-fill resin composites. Dent Mater 2015;31:1542–1551. 26608118.
24. Bucuta S, Ilie N. Light transmittance and micro-mechanical properties of bulk fill vs. conventional resin based composites. Clin Oral Investig 2014;18:1991–2000.
25. Ilie N, Bucuta S, Draenert M. Bulk-fill resin-based composites: an in vitro assessment of their mechanical performance. Oper Dent 2013;38:618–625. 23570302.
26. van Dijken JW. A 6-year prospective evaluation of a one-step HEMA-free self-etching adhesive in Class II restorations. Dent Mater 2013;29:1116–1122. 24011496.
27. Pallesen U, van Dijken JW, Halken J, Hallonsten AL, Höigaard R. A prospective 8-year follow-up of posterior resin composite restorations in permanent teeth of children and adolescents in Public Dental Health Service: reasons for replacement. Clin Oral Investig 2014;18:819–827.
28. van Dijken JWV, Pallesen U. Durability of a low shrinkage TEGDMA/HEMA-free resin composite system in Class II restorations. A 6-year follow up. Dent Mater 2017;33:944–953. 28545657.
29. van Dijken JW, Lindberg A. A 15-year randomized controlled study of a reduced shrinkage stress resin composite. Dent Mater 2015;31:1150–1158. 26205382.
30. van Dijken JW, Pallesen U. Eight-year randomized clinical evaluation of Class II nanohybrid resin composite restorations bonded with a one-step self-etch or a two-step etch-and-rinse adhesive. Clin Oral Investig 2015;19:1371–1379.
31. van Dijken JW, Pallesen U. A randomized 10-year prospective follow-up of Class II nanohybrid and conventional hybrid resin composite restorations. J Adhes Dent 2014;6:585–592.
32. Campos EA, Ardu S, Lefever D, Jassé FF, Bortolotto T, Krejci I. Marginal adaptation of Cass II cavities restored with bulk-fill composites. J Dent 2014;42:575–581. 24561041.
33. Veloso SRM, Lemos CAA, de Moraes SLD, do Egito Vasconcelos BC, Pellizzer EP, de Melo Monteiro GQ. Clinical performance of bulk-fill and conventional resin composite restorations in posterior teeth: a systematic review and meta-analysis. Clin Oral Investig 2019;23:221–233.
34. Van Meerbeek B, Yoshihara K, Van Landuyt K, Yoshida Y, Peumans M. From Buonocore's pioneering acid-etch technique to self-adhering restoratives. A status perspective of rapidly advancing dental adhesive technology. J Adhes Dent 2020;22:7–34. 32030373.
35. Peumans M, De Munck J, Van Landuyt K, Van Meerbeek B. Thirteen-year randomized controlled clinical trial of a two-step self-etch adhesive in non-carious cervical lesions. Dent Mater 2015;31:308–314. 25637318.

Article information Continued

Table 1

The materials, chemical composition and application procedure

Material Composition Application procedure
SDR (Dentsply DeTrey, Konstanz, Germany)
Lot No.: 01193
Filler: Barium-alumino-fluoro-borosilicate glass, strontium alumino-fluoro-silicate glass 1. Apply in 4 mm layers
Matrix: modified urethane (68% w) dimethacrylate resin, ethoxylated bisphenol-A dimethacrylate, triethyleneglycol dimethacrylate, camphorquinone, butylated hydroxyl toluene, UV stabilizer, titanium oxide, iron oxide pigments 2. Light-cure for 20 seconds
CeramX (Dentsply DeTrey, Konstanz, Germany)
Lot No.: 0823
Filler: Barium–aluminum-borosilicate glass (1.1–1.5 µm), methacrylate functionalized silicone dioxide nano filler (10 nm) (76% w) 1. Apply in 2 mm layers
Matrix: Methacrylate modified polysiloxane, dimethacrylate resin, fluorescent pigment, UV stabilizer, stabilizer, camphorquinone, ethyl-4 (dimethylamino) benzoate, titanium oxice pigments, aluminum silicate pigments 2. Light-cure for 20 seconds
Clearfil SE Bond (Kuraray Noritake, Osaka, Japan)
Lot No.: 000273
Primer: Water, 10-MDP, HEMA, camphorquinone, hydrophilic dimethacrylate 1. Apply primer and leave in place for 20 seconds
Bond: 10-MDP, Bis-GMA, HEMA, camphorquinone, hydrophobic dimethacrylate, N,N-diethanol p-toluidine bond, colloidal silica 2. Dry with air stream to evaporate the volatile ingredients
3. Apply bond and then create a uniform film using a gentle air stream
4. Light-cure for 10 seconds

Composition as provided by the manufacturers.

Bis-GMA, bisphenol-glycidyl methacrylate; 10-MDP, 10-methacryloyloxydecyl dihydrogen phosphate; HEMA, hydroxyethylmethacrylate.

Table 2

Modified USPHS criteria for direct clinical evaluation

Category Score Criteria
Acceptable Unacceptable
Anatomical form 0 The restoration is contiguous with tooth anatomy
1 Slightly under- or over-contoured restoration; marginal ridges slightly under contoured; contact slightly open (may be self-correcting); occlusal height reduced locally
2 Restoration is under contoured, dentin or base exposed; contact is faulty, not self-correcting; occlusal height reduced; occlusion affected
3 Restoration is missing partially or totally; fracture of tooth structure; shows traumatic occlusion; restoration causes pain in tooth or adjacent tissue
Marginal adaptation 0 Restoration is contiguous with existing anatomic form; explorer does not catch
1 Explorer catches, no crevice is visible into which explorer will penetrate
2 Crevice at margin, enamel exposed
3 Obvious crevice at margin, dentin or base exposed
4 Restoration mobile, fractured or missing
Color match 0 Very good color match
1 Good color match
2 Slight mismatch in color, shade or translucency
3 Obvious mismatch, outside the normal range
4 Gross mismatch
Marginal discoloration 0 No discoloration evident
1 Slight staining, can be polished away
2 Obvious staining cannot be polished away
3 Gross staining
Surface roughness 0 Smooth surface
1 Slightly rough or pitted
2 Rough, cannot be refinished
3 Surface deeply pitted, irregular grooves
Caries 0 No evidence of caries contiguous with the margin of the restoration
1 Caries is evident contiguous with the margin of the restoration

Table 3

Distribution of the restored teeth

Tooth type Mandibula Maxilla Total
SDR + CeramX CeramX SDR + CeramX CeramX
Premolars 8 8 10 8 34
Molars 13 11 11 11 46
Total 40 40 80

Table 4

The failed restorations after 3-year, tooth type and reason for failure

Materials Tooth type Reason for failure
SDR + CeramX Maxillary premolar Resin composite fracture
CeramX Mandibular premolar Resin composite fracture
CeramX Mandibular molar Resin composite fracture
CeramX Maxillary molar Tooth fracture and resin composite fracture

Table 5

Scores for the evaluated Class II restorations at baseline and after 1, 2, and 3 years of CeramX and SDR + CeramX given as relative frequencies (%)

Criteria Restoration Evaluation period 0 1 2 3 4
Anatomical form SDR + CeramX Baseline 97.5 2.5 0 0
CeramX Baseline 92.5 7.5 0 0
SDR + CeramX 1 year 97.5 2.5 0 0
CeramX 1 year 92.5 7.5 0 0
SDR + CeramX 2 year 95 5 0 0
CeramX 2 year 92.5 7.5 0 0
SDR + CeramX 3 year 92.5 5 0 2.5
CeramX 3 year 87.5 5 2.5 5
Marginal adaptation SDR + CeramX Baseline 97.5 5 0 0 0
CeramX Baseline 95 5 0 0 0
SDR + CeramX 1 year 97.5 5 0 0 0
CeramX 1 year 95 5 0 0 0
SDR + CeramX 2 year 95 5 0 0 0
CeramX 2 year 90 5 5 0 0
SDR + CeramX 3 year 92.5 5 0 2.5 0
CeramX 3 year 87.5 2.5 2.5 7.5 0
Color match SDR + CeramX Baseline 65 35 0 0 0
CeramX Baseline 62.5 37.5 0 0 0
SDR + CeramX 1 year 62.5 37.5 0 0 0
CeramX 1 year 57.5 42.5 0 0 0
SDR + CeramX 2 year 57.5 42.5 0 0 0
CeramX 2 year 50 50 0 0 0
SDR + CeramX 3 year 57.5 40 2.5 0 0
CeramX 3 year 42.5 50 7.5 0 0
Marginal discoloration SDR + CeramX Baseline 100 0 0 0
CeramX Baseline 100 0 0 0
SDR + CeramX 1 year 100 0 0 0
CeramX 1 year 100 0 0 0
SDR + CeramX 2 year 97.5 2.5 0 0
CeramX 2 year 95 5 0 0
SDR + CeramX 3 year 95 5 0 0
CeramX 3 year 92.5 5 2.5 0
Surface roughness SDR + CeramX Baseline 100 0 0 0
CeramX Baseline 100 0 0 0
SDR + CeramX 1 year 97.5 2.5 0 0
CeramX 1 year 97.5 2.5 0 0
SDR + CeramX 2 year 95 5 0 0
CeramX 2 year 95 5 0 0
SDR + CeramX 3 year 95 5 0 0
CeramX 3 year 92.5 7.5 0 0
Caries SDR + CeramX Baseline 100 0
CeramX Baseline 100 0
SDR + CeramX 1 year 100 0
CeramX 1 year 100 0
SDR + CeramX 2 year 100 0
CeramX 2 year 100 0
SDR + CeramX 3 year 100 0
CeramX 3 year 100 0

The experimental and control restorative techniques at the same evaluation period were compared via the Mann-Whitney U test. The analysis of data acquired by the same restorative techniques at different evaluation times was performed through the nonparametric Friedman's 2-way analysis of variance test.